Overview: The document describes the Haefely 2840 High-Precision C, L & tan δ Measuring Bridge, a sophisticated instrument designed for measuring low dielectric losses and impedances in high-voltage apparatus. It integrates advanced signal analysis capabilities and features a compact, reliable design with an embedded industrial computer.
Features: The device offers high accuracy in capacitance and tan δ measurements, integrated tools like a spectrum analyzer, digital scope, and data logger, and a user-friendly graphical interface with a large touch screen. It supports both manual and automated test modes.
Benefits: The system is easy to operate, supports a wide range of applications, and can replace outdated models using existing cable sets. It provides a complete measuring system from one supplier, including power supplies and calibration support.
Applications: Suitable for routine and type tests on power cables, shunt reactors, capacitors, insulations, transformers, and bushings. It is also applicable in metrology institutes and R&D.
Technical Specifications: The document details the measurement ranges, accuracy, and resolution for various parameters like dissipation factor, power factor, capacitance, inductance, test voltage, and current. It also specifies operating conditions, interfaces, and data formats.
Operation and Analysis: The instrument's software allows for efficient test sequence programming and execution, with features like temperature correction and pass/fail limits. It supports data visualization and trending analysis, enhancing its utility in high-voltage equipment analysis.
Reporting: Measurement data is saved in XML and CSV formats, facilitating easy report generation and data transfer to database applications.
Scope of Supply: The package includes the measuring bridge, mains cable, operating instructions, and test certificate. Various accessories and options are available for different connection needs.
Contact Information: The document provides contact details for Haefely's offices in Europe, Asia, and North America for sales and service inquiries.
See more

Catalog excerpts

2840-1

2840 High-Precision C, L & tan Measuring Bridge Additional signal analysis capabilities like Spectrum Analyser, Digital Scope and Data Logger are integrated Advanced, well-engineered test equipment, optimised to the specific application Compact, reliable and EMC hardened design Integrated solution with built-in industrial computer The Dielectric-Loss Analyzing System 2840 is designed for measurement of very low dielectric losses and impedances (Dissipation Factor and Power Factor) of high-voltage apparatus (e.g. extruded insulation on power cables). Easy to operate with Manual and Automated test modes, Software assisted test preparation, Execution and Trend analysis. The instrument works on the principle of a combined bridge-vector-meter and is capable of analyzing capacitive and inductive loads – especially shunt reactors – with outstanding accuracy and stability certified by a leading metrology institute. Complete Measuring System including power supplies, standard capacitors, current comparators, test cells, application support and calibration from one supplier. Wide Application Range. Losses of all types of insulation including shunt reactors under unstable power frequency can be measured. Upgrade - Outdated Tettex bridge models (e.g. 2877, 2801, 2821, etc.) can be easily replaced, with existing cable sets. The Graphical User Interface of the instrument is highly intuitive, focussed on convenience with built-in useful programs (e.g. support tool for tuning the external High Voltage supply) and uses a large colour touch screen as the input device. The operator can choose between manual or automatic modes. While the manual mode provides quick measurements, the automatic test mode supports complete automated test sequences. Advanced software functionalities such as insulation temperature correction, programmable test sequences with pass/fail limits, graphical visualisation of measured data, etc. make this instrument a powerful tool for analysis of highvoltage equipment. The instrument incorporates standard interfaces (e.g. USB) which enable easy exchange of measurement results, related settings, etc. for further analysis or reporting. APPLICATIONS Routine and type tests of Power Cables & Accessories Shunt Reactors Liquid or Solid Insulations Instrument Transformers Metrology Institutes Research & Development a brand of Haefely is a subsidiary of Hubbell Incorporated. Haefely has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice.

 Open the catalog to page 1
2840-2

EASY OPERATION ANALYSIS FUNCTION With its self-explanatory graphical user interface this equipment is designed for simple operation. Test planning, preparation, execution and first assessment can be handled with just a fingertip. Additionally the touch-screen seals the equipment against environmental influences. If desired a USB keyboard and mouse can also be connected. The graphical display of measured data makes this instrument a powerful tool for analysis of high-voltage equipment. The analysis function can be used as follows: Comparison against limits (Pass/fail level) Trending Analysis (comparison...

 Open the catalog to page 2
2840-3

TECHNICAL SPECIFICATIONS Range Dissipation Factor (tan ) Power Factor (cos ) Test Voltage Test Current @ Input Cn Test Current @ Input Cx Test Frequency Recorded Values Measuring Time DF (tan), DF (tan)@20°C , DF (tan) [%], DF (tan) [%]@20°C , PF (cos), PF (cos)@20°C , PF (cos) [%], PF (cos) [%] @20°C , QF (quality factor), QF (quality factor)@20°C , CP (ZX= CP RP), RP (ZX= CP RP), CS (ZX= CS + RS), RS (ZX= CS + RS), LS (ZX= LS + RS), RS (ZX= LS + RS), LP (ZX= LP RP), RP (ZX= LP RP), Cn (Standard Capacitor Value), URMS, U/ 3, Ix RMS, In RMS, Im, Ife, Impedance Zx, Phase-angle (Zx), Admittance...

 Open the catalog to page 3
2840-4

High-precision C, L & tan Measuring Bridge 2840 Instrument Mains cable (country specific) Operating Instructions and Test Certificate For the connection cables please select desired type and length in “Accessories and Options”. ACCESSORIES AND OPTIONS Order code Office Software package. Used for PC test preparation, data visualisation, staff education Complete connection cable kit for large DUT (e.g. power transformer) connection, including: Earthing cable with gripper, V-point connection cable (black), 1 measuring cable (blue) with clamps, 1 small clamp adaptor for measuring cables, Cn cable...

 Open the catalog to page 4

All Haefely AG catalogs and technical brochures

  1. DDX 9160/9161

    11  Pages

  2. VITAS 2772

    4  Pages

  3. CITAS 2771

    4  Pages

  4. AXOS

    7  Pages

  5. PGR

    4  Pages

  6. CTTS Series

    8  Pages

  7. KIT 4.0

    10  Pages

  8. PSURGE 30.2

    4  Pages

  9. MAG 1000

    8  Pages

  10. TTR 2796

    5  Pages

  11. PCI 811c

    4  Pages

  12. ACS

    7  Pages

  13. 2903

    4  Pages

  14. 3695

    3  Pages

  15. 2767

    4  Pages

  16. DEC 5

    2  Pages

  17. 5478

    2  Pages

  18. 5289

    1  Page

  19. 5288A

    1  Page

  20. 5250

    2  Pages

  21. 3320 2 kV

    2  Pages

  22. 2830/2831

    4  Pages

  23. 2820a

    4  Pages

  24. 260 DC

    2  Pages

  25. 2293

    4  Pages

  26. 2226a

    2  Pages

  27. TSS

    20  Pages

  28. CTT & WPU

    8  Pages

  29. SSGA 100-150

    24  Pages

  30. USG 40

    2  Pages

  31. RM 430

    2  Pages

  32. PSK

    20  Pages

  33. RIC 422

    4  Pages

  34. RSG 482

    3  Pages

  35. DMI 551

    2  Pages

  36. DiAS® 733

    6  Pages

  37. HiAS® 743

    7  Pages

  38. KFS

    2  Pages

  39. MAFS

    2  Pages

  40. GC 257

    6  Pages

  41. GC 223

    4  Pages

  42. DTTS

    8  Pages

  43. RSKF

    4  Pages

  44. AXOS 8

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.