1. Catalogs
  2. Hach
  3. Process (3)

Process (3)

Process (3)
1 / 18 PagesView full catalog

Process (3)

Product catalog summary
Hach pH/ORP Differential Sensors:
These sensors are designed for applications in drinking water, wastewater, industrial water, and environmental monitoring. Key specifications include a pH measurement range of 0 to 14, ORP range of -2000 to +2000 mV, temperature range of -5 to 95°C, and max pressure of 100 psig. They offer high sensitivity and are constructed with durable materials like LCP, PVDF, and titanium.
Sensor Types and Pricing:
Digital sensors are available in Convertible, Insertion, Sanitary, and Immersion styles, priced between $685 and $885. Analog sensors are similarly styled, priced from $548 to $748.
Accessories:
Includes digital extension cables ($101 to $254), analog interconnect cables, and junction boxes ($35 to $150).
Key Features:
These sensors provide high accuracy with a differential measurement technique, strong signal transmission, versatile mounting styles, and are suitable for aggressive applications.
High Purity Water pH/ORP System:
Engineered for precise measurement in high purity water applications, this system includes a pre-plumbed sample panel, digital electronics junction box, and flow meter. It features self-pressurizing electrodes and accurate temperature measurement.
Specifications:
pH range of -2 to 12, operating temperature range of 0 to 80°C, and pressure range of 0 to 4 bar. Pricing for the pH and ORP systems is $1,208 each, with spare electrodes priced at $466.
PHOSPHAX sc Phosphate Analyzer:
Measures PO4-P concentrations with low operational costs, featuring automatic cleaning and calibration.
Series 5000 Analyzer:
Offers reliable phosphate analysis with low maintenance and intelligent self-diagnostics.
Filtrax System:
Provides high permeate quality and low operating costs, ideal for outdoor use.
Sample Delivery and Analysis Systems:
Includes the Filtrax System, Sample Sequencer, Sample Manifold, and various analyzers. These products offer features like self-cleaning, auto-calibration, and low reagent use, enhancing reliability and efficiency.
astroTOC™ UV TOC Analyzers:
Designed for monitoring Total Organic Carbon in industrial and wastewater applications. They feature intelligent software, dual stream sample systems, and automatic calibration. The TOC Turbo Analyzer offers fast and accurate low-level TOC analysis.
Conclusion:
The document provides comprehensive information on a range of technical products designed for efficient sample delivery and analysis, aiding in informed decision-making for potential buyers.
See more

Catalog excerpts

Process (3)-1

Pr > Process Instruments Pr od. No. Price od. No. Price CONTROLLER REQUIREDFor information about Hach digital and analog controllers, see pages 385-396. PHD scDIGITAL AND PHD ANALOG SENSOR ACCESSORIES Cables Extension cables are used only with digital sensors or digitalgateways when connecting to a digital controller. PHD scDIGITAL DIFFERENTIAL pH/ORP SENSORSAll digital sensors include built-in digital electronics and integral 10 m (33 ft.) cable terminated with connector for a digital controller. Body styles: 6122400 Digital Extension Cable, 1 m (3.2 ft.) $101.005796000 Convertible Ֆ 1-inch NPT threads at both ends, designed for tee-mounting or other flow through mountings, and pipe mounting for immersion Insertion Ֆ no threads on the electrode end, designed for use with insertion valve assembly or flow-through cell Sanitary Ֆ 2-inch flange for a tri-clover style fitting Immersion Ֆ used with chain mounting or pipe mounting pH Sensors Digital Extension Cable, 7.7 m (25 ft.) 127.005796100 Digital Extension Cable, 15 m (50 ft.) 190.005796200 Body Material Digital Extension Cable, 31 m (100 ft.) 254.00 Interconnect cables are used only with analog sensors, junction box,and controller. 1W1100 Analog Interconnect Cable, order per foot 2.00 Digital Termination Box Required when the length of cable between the digital sensor/digitalgateway and a digital controller is between 100 m (328 ft.) and 1000 m (3280 ft.) Body Style 5867000 Digital Termination Box 111.00 DPD1P1 PEEK > 1 Convertible $735.00DPD1P3 > 3 Analog Junction Box PEEK > 1 Convertible 885.00DPD2P1 Required when the length of cable between the analog sensor andanalog controller is greater than standard length of sensor cable. Each junction box includes terminal strip and gasket. PEEK > 1 Insertion 760.00DPD3P1 60A2053 Junction Box, Surface-mount, aluminum 35.00 PEEK > 1 Sanitary 785.00DPD1R1 (includes mounting hardware) Ryton > 2 Convertible 685.00DPD1R3 > 3 60A9944 Junction Box, Pipe-mount, PVC 63.00 Ryton > 2 Convertible 835.00DPS1 60G2052 (for 1/2-inch diameter pipe, includes mounting hardware) Junction Box, Pipe-mount, PVC 63.00 Stainless SteelImmersion 785.00 76A4010-001 (for 1-inch diameter pipe, includes mounting hardware) Junction Box, NEMA 4X 150.00 ORP Sensors (no mounting hardware included) Body Material Body Style pHD sc Digital and pHD Analog Sensor Reagents and Standards DRD1P5 PEEK > 1 Convertible 785.00DRD1P6 PEEK > 1 Convertible 835.00DRD2P5 PEEK > 1 Insertion 810.00DRD1R5 Ryton > 2 Convertible 735.00DRD1R6 Ryton > 2 Convertible 785.00DRS5 Stainless SteelImmersion 785.00 PHD scANALOG SENSORS 25M1A1025-115 Standard Cell Solution, 48.00 pH Sensors to replenish standard cell chamber in Hach pHD sensors while replacing salt bridge, 500 mL Body Material Body Style PD1P1 PEEK > 1 Convertible 598.00PD1P3 25M8A1002-101 Gel Powder, 42.00 PEEK > 1 Convertible 748.00PD2P1 for >95C applications, 2 g PEEK > 1 Insertion 623.00PD3P1 PEEK > 1 Sanitary 648.00PD1R1 pH Buffers Ryton > 2 Convertible 548.00PD1R3 Description V olume > 3 Ryton > 2 Convertible 698.00 2283549 pH 7500 mL (1 pint) 9.202283449 pH 4500 mL (1 pint) 9.202283649 ORP Sensors pH 10500 mL (1 pint) 9.20 Body Material Body Style RD1P5 PEEK > 1 Convertible 648.00RD1P6 ORP Reference Solutions (in resealable plastic bottles) PEEK > 1 Convertible 698.00RD2P5 Description V olume PEEK > 1 Insertion 673.00RD1R5 25M2A1001-115 200 mV500 mL (1 pint) 42.0025M2A1002-115 Ryton > 2 Convertible 598.00RD1R6 600 mV500 mL (1 pint) 42.00 Ryton > 2 Convertible 648.00 > 1 Polyetheretherketone; 2 Polyphenelene Sulfide; 3 HF resistant glass pH/ORP systems with Class I Division II safety classification areavailableЗ please contact your Hach representative. DIGITAL GATEWAY 6120500 Use the Digital Gateway to connect pHD 101.00 analog sensors to a Hach digital controller. >

 Open the catalog to page 1
Process (3)-2

Process Instruments These field-proven differential electrodes are available in LCP (foreground) or Ryton > body materials. They provide greater reliability and reduced maintenance. > Platinum ORP (Gold ORP also available)Antimony Sensor > Ε Drinking Water Wastewater Օ Industrial Water Environmental > Wetted Materials LCP body, PVDF junction, Viton O-rings, glass electrode, and titanium ground rod > Weight ~1.3 lbs. (0.6 kg) Measuring Range pH: 0 to 14 pH ORP: -2000 to +2000 mV Temperature Range -5 to 95հC (23 to 203F) > *Subject to change without notice.

 Open the catalog to page 2
Process (3)-3

Process Instruments Hachs unique Differential Sensor Technology uses three measuring electrodes instead of thetwo in conventional pH sensors. The process electrode and standard electrode measure the pH differentially with respect to a third ground electrode.This technique is proven to provide unsurpassed accuracy, reduce reference junction fouling,and virtually eliminate ground loops. The benefit is greater reliability with less downtime and maintenance. > Hach Company offers the best sensor warranty in the industry on its Differential Sensors. We will replace any Differential Sensor that fails...

 Open the catalog to page 3
Process (3)-4

Process Instruments Digital combination pH and ORP sensors are available in convertible, insertion, and sanitary mounting styles. Choose from rugged dome electrodes or easy-to-cleanӔ flat glass electrodes. > Drinking Water Օ Wastewater Industrial WaterՕ Environmental > pH Range 0 to 14 pH Operating Temperature Range 0 to 105C (32 to 221аF) > 0 to 6.9 bar (100 psi) ORP Range -2000 to +2000 mV Operating Temperature Range 0 to 105װC (32 to 221F) Pressure Range 0 to 6.9 bar (100 psi) > *Dependent on specific sensor and mounting.

 Open the catalog to page 4
Process (3)-5

Process Instruments CONTROLLER REQUIREDFor information about Hach digital and analog controllers, see pages 385-396. Pr Pr od. No. Price od. No. Price DIGITAL PC scAND RC sc3/4-INCH COMBINATION PH/ORP SENSORSAll PC sc and RC sc 3/4-inch combination sensors come completewith an integral 4.5 m (15 ft.) sensor cable, Digital Gateway, and 1 m (3.3 ft.) digital extension cable.Measur Cables Digital cables are used only with digital sensors or gateways whenconnecting to a digital controller. 6122400 Digital Extension Cable, 1 m (3.3 ft) $101.005796000 Digital Extension Cable, 7.7 m (25 ft) 127.005796100...

 Open the catalog to page 5

All Hach catalogs and technical brochures

  1. Flow

    22  Pages

  2. Process (4)

    14  Pages

  3. Process (2)