Process Instruments Ε Wastewater Industrial WaterՕ Drinking Water > LDO Flow CellNew and improved Air Blast Head Measuring Range Sensitivity Probe Immersion Depth andPressure Limits 0 to 20.0 ppm, 0 to 20.0 mg/L, 0 to 200% saturation 0.5% of span Accuracy 107 m (350 ft.), 1050 kPa (150 psi), maximum > Measurement: ѱ0.2% of spanTemperature: 0.2ѰC Transmission Distance 100 m (328 ft.) maximum1000 m (3280 ft.) maximum whenused with a termination box Repeatability > Sensor Cable (integral) To 90% in less than 40 seconds To 95% in less than 60 seconds Resolution 10 m (33 ft.) terminated with quick-disconnect plug > Probe: Foamed Noryl > and 316stainless steel Sensor: Polybutyl methacrolate > No interferences from the following:H 60 x 292 mm (2.4 x 11.5 in.) > Probe: 3 Years; Sensor Cap: 1 Year > Hazardous Location Ratings > +1 +1 +2 +2 2 S, pH, K , Na , Mg , Ca ,NH ETL listed (cETLus marked) toCanadian and US General Safety and Hazardous (Class I, Div. 2)Locations > +3 +2 +2 +2 4+3 , Cl , anion active tensides,crude oils, or Cl > 2-1 ή is a registered trademark ofGeneral Electric Co. Operating Temperature 0 to 50C (32 to 122аF) > Flow Rate > *Subject to change without notice.
Open the catalog to page 1The Hach Orbisphere G1100 Luminescent Dissolved Oxygen (LDO)Sensor is the first luminescent sensor to provide trace oxygen monitoring in pure water processes where ppb level monitoring is needed. It features traceable fully automatic in-situ calibration and low cost of ownershipdowntime is reduced to 5 minutes annual service. A dry sensor means there is no electrolyte, no chemicals, and no membrane. > Process Instruments All analyzers are equipped with 1/4-in. sample inlet, 85 to 264 Vac,3 x 0/4-20 mA analog output, and RS485. Pr od. No. Description Price 41G1-W400 Hach Orbisphere$6,858.00luminescent...
Open the catalog to page 2Process Instruments HachՒs galvanic membrane dissolvedoxygen sensor has a replaceable membranecartridge that simplifies the task of installingnew membranes. Sensor Cable (integral) 10 m (33 ft.) terminated with quick-disconnect plug Wetted Materials Noryl > WastewaterՕ Industrial Water > Accuracy > Ѯ body, PVC mounting adapter,Viton > Measurement: 2% of span Temperature: ѱ0.2C Repeatability > Ю O-rings, polypropylenemembrane, Noryl > Response Time at 20κC cartridge assembly, and nylon cable grip/strain relief Electrode Materials To 90% in 120 seconds > Operating Temperature Nickel-chrome cathode,...
Open the catalog to page 3Process Instruments Pure Water/PowerՕ Industrial Water > Accuracy ұ1% of reading or 1.5 ppb,whichever is greater Drift of Sensitivity ѱ0.5% per month,non-accumulative Speed of Response 90% in approximately 30 seconds Measuring Range 0 to 80 ppm Compensated Temperature Range 0 to 50C Display Backlit dot matrix LCD Relays Four SPDT Outputs Two isolated 0/4 Ж20 mA (user adjustable),and RS-232 Temperature Compensation Automatic, 0 to 50C (32 to 122аF) Power 105 to 250 Vac, 50 to 60 Hz. EMI/RFI Immunity CE compliant Enclosure 1/2 DIN NEMA 4X with hardware for panel, surface, and pipe mounting Membrane...
Open the catalog to page 4Process Instruments Pr od. No. Description Price SYSTEM PACKAGES 085G4000 085G4001 OXY System Package 1 OXY System Package 2 $3,118.00 2,641.00 Includes USC 6000, OXY 4100 DO Transmitter (Ball Float Style), OXY 1100 Membrane Cartridge, Mounting Bracket Includes USC 5000, OXY 4100 DO Transmitter (Ball Float Style), OXY 1100 Membrane Cartridge, Mounting BracketOXY System Package 3 Call for detailsOXY 4100 DO Transmitter (Ball Float Style) Must specify measurement range, OXY 1100 Membrane Cartridge, Mounting Bracket > REPLACEMENT TRANSMITTERMust specify range if not used with USC, call for details....
Open the catalog to page 5Ensure the health of your distribution systembuild a distribution monitoring network for maximum surveillance capability. ו Detect cross connection in real time Detect contamination eventsintentional oraccidental Stay alert to quality degradation due to water age Օ Identify degradation in water quality due to biofouling Locate and monitor dead ends and low flow areas ofthe systemՕ Detect corrosion by-products, improve corrosioncontrol Alert operators and managers to undesirable changesin water quality Օ Reduce labor costs associated with time and travel toperform grab sampling Troubleshoot distribution...
Open the catalog to page 6Process Instruments Alarms Weight Trigger Signal Alarm, High/LowParameter Alarms, Frozen ParameterAlarm, Sensor Off-line Alarm; Plant Alarm; Missing Sensor; Invalid Data 65 lbs. (29 kg) > Enclosure Material 316 Stainless steel > Power Requirements Mounting > 115 Vac, 100 W Wall mount or rack mount > Operating Temperature Display > 5 to 40C 15" touch screen Storage Temperature -20 to 65ںC Certification Listed to UL 1010 by ETS Humidity 95% at 40C max Instrumentation Interfaces with Hach WDM Panel orHach PipeSonde In-Pipe Probe;astroTOC UV On-line TOC Analyzer; Hach Sigma Portable, Refrigerated,or...
Open the catalog to page 7The right tool to establish your distribution systemՒs waterquality baselineField proven instruments you can count on ՕMultiparameter on-line panel includes pH, conductivity,chlorine (free or total) and turbidity, additional parameter optionalFlexible system can be optimized with the Event MonitorTrigger System, On-line TOC Analyzer, Automatic Sampler, and ORP ProbeՕ Single sample inlet, outlet, and power hook-ups for ready-to-install convenience The Right Tool to Establish Your DistributionSystems Baseline > Process Instruments The initial step in knowing the health of your water distributionsystem...
Open the catalog to page 8Process Instruments 0-14 pH Range Range Sensitivity sc1000 CONTROLLERDimensions 0 to 5 mg/L free or total residual chlorine Less than 0.005 pH Accuracy Stability 22 x 51.5" 5% or 0.035 mg/L as Cl > 2 , whichever is greater 0.03 pH per 24 hours, non-cumulative SAMPLE REQUIREMENTS Sample Inlet 1/2" OD Tube Connection Precision Sample Flow ѱ5% or 0.005 mg/L as Cl > 2 , whichever is greater 400-600 mL/min Minimum Detection Limit Sample Pressure 0.035 mg/L > 20 - 125 psig Sample Operating Temperature 5 to 40C > Range Waste/Drain Range 0-2000 ڵS/cm 3/4" NPT Hose Barb Connection 0.01-100 Nephelometric...