Process Controller P1611100 0 to 10 VDC or 0/4 to 20mA Input Specification Display The Model P161100 Controller accepts either a 0 to 10 VDC or 0/4 to 20 mA DC input signal and provides accurate output control to maintain a process at a set value. Dual 4-digit displays allow viewing of the process value and set-point simultaneously. Front panel indicators show the control and output status. The PID programming or On/Off control allows these controllers to meet a wide variety of application requirements. Input input Range 2 Line by 4-digit, LCD negative image transmissive with backlighting Top (Process) Display 7.6 mm high digits with red backlighting Bottom (Parameter) Display 5.1 mm high digits with green backlighting Annunciators Status Annunciators: O1 Main control output is active. O2 Cooling output is active (when Alarm 2 is used for cooling) A1 Alarm 1 output is active A2 Alarm 2 output is active °F, °C Temperature units %PW Output power percentage is shown in Bottom display MAN Controller is in Manual Mode R Ramping Setpoint indicator % Percent indicator Display Messages: OLOL Measurement exceeds + sensor range ULUL Measurement exceeds - sensor range SENS Measurement exceeds controller limits dddd Display value exceeds + display range -ddd Display value exceeds - display range Power 85 to 250 VAC, 50/60Hz, 8 VA Control and Alarm Outputs Relay Output Type Form A Contact Rating 3 A @ 250 VAC or 30 VDC; 1/10 HP @ 120 VAC (inductive load) H&B Sensors Ltd | Odyssey House | Durban Road | Bognor Regis | West Sussex | PO22 9RH | United Kingdom Tel: +44(0)1243 866866 | Email: sales@hbsensors.com | www.hbsensors.com

Open the catalog to page 1
Process Controllers P1611100 - 2

Life Expectancy 100,000 cycles at max. load rating Logic/SSR Output Rating: 45 mA max @ 4 V min., 7 V nominal (main control output only) Main Control PID or On/Off Output Time proportioning or DC Analog Cycle Time Programmable Auto-Tune When selected, sets proportional band, integral time, derivative time, and output dampening time Also sets input filter and (if applicable) cooling gain Probe Break Action Programmable Alarms 2 relay alarm outputs Modes None Absolute High Acting (Balanced or Unbalanced Hysteresis) Absolute Low Acting (Balanced or Unbalanced Hysteresis) Deviation High Acting...

Open the catalog to page 2

All H&b Sensors catalogs and technical brochures

  1. Bimetallic A

    2 Pages

  2. 5333A

    2 Pages

  3. PAXP0000

    2 Pages

  4. HBS16000

    1 Pages