Process Controller P1611100 0 to 10 VDC or 0/4 to 20mA Input Specification Display The Model P161100 Controller accepts either a 0 to 10 VDC or 0/4 to 20 mA DC input signal and provides accurate output control to maintain a process at a set value. Dual 4-digit displays allow viewing of the process value and set-point simultaneously. Front panel indicators show the control and output status. The PID programming or On/Off control allows these controllers to meet a wide variety of application requirements. Input input Range 2 Line by 4-digit, LCD negative image transmissive with backlighting Top (Process) Display 7.6 mm high digits with red backlighting Bottom (Parameter) Display 5.1 mm high digits with green backlighting Annunciators Status Annunciators: O1 Main control output is active. O2 Cooling output is active (when Alarm 2 is used for cooling) A1 Alarm 1 output is active A2 Alarm 2 output is active °F, °C Temperature units %PW Output power percentage is shown in Bottom display MAN Controller is in Manual Mode R Ramping Setpoint indicator % Percent indicator Display Messages: OLOL Measurement exceeds + sensor range ULUL Measurement exceeds - sensor range SENS Measurement exceeds controller limits dddd Display value exceeds + display range -ddd Display value exceeds - display range Power 85 to 250 VAC, 50/60Hz, 8 VA Control and Alarm Outputs Relay Output Type Form A Contact Rating 3 A @ 250 VAC or 30 VDC; 1/10 HP @ 120 VAC (inductive load) H&B Sensors Ltd | Odyssey House | Durban Road | Bognor Regis | West Sussex | PO22 9RH | United Kingdom Tel: +44(0)1243 866866 | Email: [email protected] | www.hbsensors.com

 Open the catalog to page 1
Process Controllers P1611100-2

Life Expectancy 100,000 cycles at max. load rating Logic/SSR Output Rating: 45 mA max @ 4 V min., 7 V nominal (main control output only) Main Control PID or On/Off Output Time proportioning or DC Analog Cycle Time Programmable Auto-Tune When selected, sets proportional band, integral time, derivative time, and output dampening time Also sets input filter and (if applicable) cooling gain Probe Break Action Programmable Alarms 2 relay alarm outputs Modes None Absolute High Acting (Balanced or Unbalanced Hysteresis) Absolute Low Acting (Balanced or Unbalanced Hysteresis) Deviation High Acting Inside...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.