TYP I-TS-3870 & TYP MI-TS-3871
12Pages

{{requestButtons}}

Catalog excerpts

TYP I-TS-3870 & TYP MI-TS-3871 - 1

Infeed Test System

Open the catalog to page 1
TYP I-TS-3870 & TYP MI-TS-3871 - 2

Infeed Test System – Type I-TS-3870 General Data: • Power single system up to 650 kW • Total power parallel system up to 1.3 MW • Output voltage single system up to 1000 V • Output current single system up to 1000 A (higher output current on request) Typical applications: • Battery simulation (BS) • Battery test (BT) • Testing fuel cell • Testing solar panels • Testing of charging stations (comemso) • Power

Open the catalog to page 2
TYP I-TS-3870 & TYP MI-TS-3871 - 3

Applications (depending on configuration) Infeed Test System – Type I-TS-3870: DC – Test of battery charging and discharging U Load for fuel cells (with safety function) I Power supply and power deduction of powertrain Testing power supply for fuses, contactors and MCCB Test of DC-motors Main bidirectional converter Energy flow Up to 4 individual controllable DC-outputs Subject to change without noti

Open the catalog to page 3
TYP I-TS-3870 & TYP MI-TS-3871 - 4

Types / Technical data Typ Typical current rise time 10 % - 90 % (ms) AC - Input voltage / AC – Input frequency Measuring resolution Control accuracy Voltage tolerance dynamic (0 – 100 % INom in 3 ms) 380 / 400* / 440 / 480 / 500 / 690 V ±10 %, 3-phase, PE, 50 / 60 Hz ± 6 % voltage: 16 Bit ADC current: 16 Bit ADC voltage 0.1 % fs current 0.1 % fs < 3 % fs Voltage ripple Current ripple Short circuit behavior Permissible ambient temperature Climate class Distance from ceiling min. Installation Protection class Safety Basic standard Short circuit proof (Ik < 3 kA) +5 to +40 °C 1K21/1M11...

Open the catalog to page 4
TYP I-TS-3870 & TYP MI-TS-3871 - 5

Characteristics and basic equipment • „Battery tester“ version • top button (black mushroom button) in cabinet door S • Highly dynamic inverter • Voltmeter and ready indicator light in cabinet door • Short circuit proof < 3 kA, < 8 kA at 1000 A systems • Electrical isolation to grid • onnection terminals for DC voltage measurement C (0.1 % fs accuracy with sense lines) • Connection terminals for external „Emergency Stop“ • DC current measurement with 0.1 % fs accuracy • Connection terminals for external „Stop“ • urrent rise time < 1 msec (300 - 800 V), C • Connection terminals for...

Open the catalog to page 5
TYP I-TS-3870 & TYP MI-TS-3871 - 6

High Speed Analogue / Controlling Ethernet / Diagnosis and Debugging Analogue / Controlling Profibus / Controlling safety Powerlink CAN-Bus intern Ethernet / Controlling CAN-Bus / Controlling Performance level „d“ (machine directive: EN ISO 13849-1) • Redundant Hardware • Redundant wiring • Two separate channels • Constant test of inputs and outputs • Safe shutdown in case

Open the catalog to page 6
TYP I-TS-3870 & TYP MI-TS-3871 - 7

Using batteries to increase max. power 250 kW from grid Power supply with internal energy recovery for Charging Post development and testing of e-powertrain Control Unit converter Charging Post motor Control Unit converter Charging Post V Battery Control Unit

Open the catalog to page 7
TYP I-TS-3870 & TYP MI-TS-3871 - 8

Power supplies for internal devices during service and repair of high speed trains ICE Control device © AST, Wolnzach Fuel cell testing 60 – 650 kW

Open the catalog to page 8
TYP I-TS-3870 & TYP MI-TS-3871 - 9

DC application: EVSE Test (DC EV Simulation) DC application: EV Test (DC EVSE Simulation)

Open the catalog to page 9
TYP I-TS-3870 & TYP MI-TS-3871 - 10

Options 1. Adaptation to test application 2. Adaptation to customer specification Insulation monitoring device Adaptation safe shutdown time Operating mode battery simulator Intermediate discharge DC-link Operating mode battery simulator/tester switchable Emergency stop at door Output contactor with increased short-time withstand current • Door contact/door interlock Current range switching 100% and 10% Special door lock Protective diode for sink mode Special input voltage Parallel control device Adaptation to USA/CAN market PDSB (cabinet for additional options) Cabinet lamp/cabinet heating...

Open the catalog to page 10
TYP I-TS-3870 & TYP MI-TS-3871 - 11

Exemplary Applications Optional if I-TS can´t be placed directly next to DUT. I-TS-3870 Single – Standard System PDSB optional for following applications: • Switch between multiple test cells • Installation of discharge Units • Parallel operation of 2 systems Current flow Changeover Test Cells / DUT PDU Current flow Testing one DUT and connecting simultaneously the second one Communication via Parallel Interface DC – Enlargement of output current and power

Open the catalog to page 11
TYP I-TS-3870 & TYP MI-TS-3871 - 12

Innovation and quality from Germany and Austria GUSTAV KLEIN GMBH & CO. KG D-86956 Schongau · Im Forchet 3 D-86952 Schongau, Postfach 12 48 Phone +49(0)8861/209-0, Fax +49(0)8861/209-180 E-Mail: vertrieb@gustav-klein.com www.gustav-klein.com A-6401 Inzing / Tirol · Schießstand 2 Phone +43(0)5238/54209-0 Fax +43(0)5238/54209-23 E-Mail: vertrieb@gustav-klein.com www.gustav-klein.com EN / © 2021

Open the catalog to page 12