Spabond 340LV (HT) Epoxy Adhesive System (v2)-1

Epoxy Adhesive System ■ Reduced component weights; lower density when compared to glass filled ■ Higher thermal performance & fast cure progression ■ High strength and toughness industrial adhesive ■ Excellent gap filling properties ■ Designed for cartridge and mixing machine dispense ■ Three hardener speeds give a range of working times / clamp times ■ Resin & hardener are pigmented to give a visual indication of mix quality Spabond 340 LV HT is a high performance adhesive designed for bonding large structures such as yacht hulls and wind turbine blades. It is a cost-effective system with good thermal and mechanical properties. The formulation gives high thermal performance and allows fast curing, making this product ideal for bonding large composite structures where minimising cure times and increasing productivity is of value The components are pigmented to give a visual indication of mix quality, which is a useful feature when mixing by hand or with a machine. The system has a simple 2:1 mix ratio by volume Spabond 340LV HT is available in cartridges, pails and 200 litre drums for machine mixing/dispense

 Open the catalog to page 1
Spabond 340LV (HT) Epoxy Adhesive System (v2)-2

The product is optimised for use at 15 - 25°C. At lower temperatures the components thicken and may eventually become unworkable. To ensure accurate mixing and good workability pre-warm the resin & hardener as well as the surfaces to be bonded before use Surface Preparation Before using the product ensure that surfaces to be bonded are clean, dry and dust-free. Prepare all surfaces by abrading with medium grit paper or other suitable abrasive, remove dust then wipe with acetone or Gurit's Fast Epoxy Solvent (Solvent A) Metals usually require a chemical pre-treatment to create the best bond. Please...

 Open the catalog to page 2
Spabond 340LV (HT) Epoxy Adhesive System (v2)-3

Properties (Cont'd) Notes: For an explanation of test methods used see 'Formulated Products Technical Characteristics' All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur t All times are measured from when resin and hardener are first mixed together *Clamp time data shows the time taken to achieve a 2000N bond strength. This figure allows comparison of cure speed with other adhesive products of the Spabond range However, because of the unusual cure development of this product at 15 - 30°C, the time to reach a safe handling strength...

 Open the catalog to page 3
Spabond 340LV (HT) Epoxy Adhesive System (v2)-4

Mechanical Properties Neat Resin Cast Cured Properties (Tensile Strength & Modulus) 3.5 60 3.0 50 Glass Transition Temperature (Tg1 by DSC) 40 2.0 30 1.5 20 1.0 10 0.5 0 Fast Slow 0 Extra Slow 60 Temperature (oC) 2.5 Tensile Strength (GPa) Tensile Modulus (GPa) 70 50 40 30 20 10 0 Fast Slow Extra Slow o 2 hrs. @ 23 C +10 hrs. @ 70oC 2 hrs. @ 23oC +10 hrs. @ 70oC Shear Strength on Steel & Epoxy grp (Cure: 2hrs @ 23oC + 10hrs @ 70oC) Shear Strength (MPa) 40 30 20 10 0 Fast Slow Steel 4 Extra Slow Fast Slow Extra Slow Epoxy grp PDSWE-Spabond 340LV (HT)-2-0313

 Open the catalog to page 4
Spabond 340LV (HT) Epoxy Adhesive System (v2)-5

The following points must be considered 1. Skin contact must be avoided by wearing protective gloves. Gurit recommends the use of disposable nitrile gloves for most applications. The use of barrier creams is not recommended, but to preserve skin condition a moisturising cream should be used after washing 2. Overalls or other protective clothing should be worn when mixing, laminating or sanding. Contaminated work clothes should be thoroughly cleaned before re-use. 3. Eye protection should be worn if there is a risk of resin, hardener, solvent or dust entering the eyes. If this occurs flush the...

 Open the catalog to page 5
Spabond 340LV (HT) Epoxy Adhesive System (v2)-6

Transport & Storage The resin and hardeners should be kept in securely closed containers during transport and storage. Any accidental spillage should be soaked up with sand, sawdust, cotton waste or any other absorbent material. The area should then be washed clean (see appropriate Safety Data Sheet). Adequate long term storage conditions will result in a shelf life of two years for both the resin and hardeners. Storage should be in a warm dry place out of direct sunlight and protected from frost. The storage temperature should be kept constant between 10°C and 25°C, cyclic fluctuations in temperature...

 Open the catalog to page 6

All Gurit catalogs and technical brochures

  1. PREPREGS

    11  Pages

  2. RA320H5

    1  Page

  3. XA450

    1  Page

  4. UT-EA661

    1  Page

  5. REA390S

    1  Page

  6. PB1000

    2  Pages

  7. UT-E1200

    1  Page

  8. UT-E800

    1  Page

  9. UT-E500

    1  Page

  10. UT-E250

    1  Page

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.