1. Catalogs
  2. GÜNTHER Heisskanaltechnik
  3. Hot Runner Systems for Medical Engineering

Hot Runner Systems for Medical Engineering

Hot Runner Systems for Medical Engineering

Hot Runner Systems for Medical Engineering

Product catalog summary
Principle of Thermal Separation
  • Two-part shaft design ensures effective thermal separation between the nozzle and mold insert.
  • Minimizes heat flow into the cavity, maintaining constant temperature control in the nozzle.
  • Ensures high leak tightness between nozzle and mold insert.

GÜNTHER Hot Runner Technology for Medical Engineering Applications
  • Custom solutions developed in collaboration with customers.
  • Online system configuration available through the CADHOC system designer.
  • Externally heated systems ensure optimal melt flow with low pressure drop.
  • Hot runner systems cater to diverse demands with patented two-part shaft for thermal separation.
  • Modular nozzle design and "Hot half" ready-to-install mold half.

Valve Gate Technology
  • Offers superior surface finish, high process reliability, and low shear rate to reduce part stress.
  • Modular nozzle design allows for narrow pitches and various needle actuation types.
  • Needle adjustments can be made externally without mold disassembly.
  • Wear-resistant needle guide ensures long service life with various gate diameters possible.

Innovative and Cost-effective Solutions
  • Hot runner technology is crucial for cost-effective production in medical engineering.
  • Advantages include efficient material and energy use, no waste, reduced cycle time, and improved product quality.
  • GÜNTHER is a leader in processing both standard and high-temperature resistant thermoplastics.

Applications
  • Inhaler for Asthmatics: POM parts require high dimensional accuracy and burr elimination, achieved through direct side gating with LHT nozzles.
  • Middle Section for Insulin Pen: ABS material requires precise temperature control, achieved with insulated shaft nozzles and a hot runner system.
  • Intrauterine Device: EVA/PP part requires vestige-free gate mark, achieved with thermal separation and direct gating.
  • Infusion Pump: Metal injection molding with GÜNTHER hot runner ensures precise, low-cost manufacturing with constant temperature control.
See more

Catalog excerpts

Hot Runner Systems for Medical Engineering-1

Principle of Thermal Separation • Two-part shaft for good thermal separation between nozzle and mold insert • Low heat flow into the cavity • Constant temperature control in the nozzle • High leak tightness between nozzle and mold insert GÜNTHER Hot Runner Technology for Medical Engineering Applications • Development of custom tailored solutions in close cooperation with our customers • On-line system configuration with the CADHOC system designer • Externally heated systems guarantee optimal melt flow with low pressure drop • Hot runner systems for the most varied demands • Two-part shaft for optimal thermal separation (patented) • Modular nozzle design • “Hot half” as a ready-to-install mold half Hot Runner Systems for Medical Engineering Technology For more information on our services and products, please check out our website at www.guenther-hotrunner.com GÜNTHER Heisskanaltechnik GmbH Sachsenberger Straße 1 D-35066 Frankenberg Phone +49 (0)6451 5008-0 Fax +49 (0)6451 5008-59 [email protected] www.guenther-hotrunner.com Cover: Production line for producing and bottling infusion solutions. A special closure is placed on the filled bottle and subsequently overmolded with PE. This application uses a modular valve gate hot runner system from GÜNTHER. Photo: B. Braun, GÜNTHER Valve Gate Technology Valve gate technology offers clear benefits including: • superior surface finish in the gate area • high process reliability • low shear rate of the melt to reduce orientation and residual stress of the part Valve gate technology takes advantage of a modular nozzle design. Narrow pitches are possible. One can choose between different types of needle actuation: single valve gate nozzle or, in multiple systems, single needle valve, lifting plate or sliding plate mechanism. The needle can be adjusted from the outside without mold disassembly. A wear-resistant needle guide made of PM steel guarantees long service life. Various gate diameters are possible without refinishing the inserts.

 Open the catalog to page 1
Hot Runner Systems for Medical Engineering-2

Innovative Pace setting developments in medical engineering are closely connected with plastic materials. Products with the most varied properties meet extremely high requirements of precision and functionality. Hot runner technology plays a key role in the process of cost effective production. Cost effective Advantages of hot runner technology: • efficient use of material and energy • no waste • cycle time reduction • reliable injection process • improved product quality • highest production reliability • integration into clean room production Patented As a specialist for technically demanding...

 Open the catalog to page 2

All GÜNTHER Heisskanaltechnik catalogs and technical brochures

  1. OktaFlow

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.