Temperature Measurement Technology Temperature Measurement Technology GUNTHER temperature sensors in action 4 Principles of temperature measurement 6 Temperature measurement using thermocouples 8 Using resistance thermometers Thermocouple assemblies with metal protection tube Thermocouple assemblies with ceramic Protection tube Thermocouple assemblies with noble metal protection tube Thermocouple assemblies with metal protection tube and mineral-insulated measuring insert Thermocouple assemblies for welding with thermowell form 4 (former D-sleeve) Thermocouple assemblies with welded blank flange...
Open the catalog to page 350 years of precision Starting with the founding year in 1968, the name GÜNTHER remains Success through preparation symbolic of state-of-the-art solutions in temperature measuring tech- At our five international production sites, we are able to manufac- nology. Having started with the production of electronic temperature ture almost any required, customized component for our custom- sensors for industrial furnaces, we have continually developed and ers. Industry standard dimensions of rare/noble metal thermowells, expanded our expertise, offering our services to an increasing variety thermocouple...
Open the catalog to page 4GÜNTHER GmbH Temperature Measurement Technology Diversity through progress Introduction Moreover, the continuous expansion of our expertise on an international scale remains as a firm cornerstone of our company philosophy. Always on the cutting edge, with an eye on the future, we go beyond providing our customers morn and precise solutions, leading the way in the field of temperature measurement. Only in this fashion, are we able to meet a variety of application scenarios and offer customized temperature sensors, while keeping an eye on the future and sustaining preparedness in meeting the varying,...
Open the catalog to page 5GÜNTHER temperature sensors in action GÜNTHER temperature sensors in action Our temperature sensors find application in a diversity of industry sectors all around the world, wherever their exact measurements are required, all throughout the various stages of manufacturing processes. This is a summary of the most common sectors and areas of application: Visit us online at www.guenther.eu
Open the catalog to page 6Food industry Heat treatment Chemicals industry Applied sensors: Applied sensors: Applied sensors: GÜNTHER GmbH Temperature Measurement Technology Aluminium and non-ferrous metal industry Applied sensors: 00-TMT / 05-TKT / 10-TMM 20-TOM / 30-WTE / 35-WGG Cement and building material industry Applied sensors: 00-TMT / 05-TKT / 10-TMM 15-TKM / 20-TOM Plastic industry Applied sensors: 20-TOM / 52-WOS 60-WTH / 72-KFW GÜNTHER GmbH Areas of application Introduction
Open the catalog to page 7Principals of temperature measurement Principals of temperature measurement Essentially, there are several physically different possibilities of If there is no difference in temperature, both of these contact voltages measuring temperature, such as gas or liquid thermometers, bimetal- cancel each other out. If the points of contact have different tempera- lic strip thermometers, pyrometers, thermal imaging and of course tures, a measurable thermoelectric current starts flowing. thermocouples and resistance thermometers Principals of resistance thermometers The last two are examples known as measuring...
Open the catalog to page 8Both principals share the property that the thermometer can For this reason, the main challenge in constructing a suit- only indicate the temperature that exists at the point of mea- able temperature sensor is finding the optimal compromise surement. In order to receive precise measurements, it is es- between reaction time, holding time, measurement precision sential for the point of measurement to have acquired an identi- GÜNTHER GmbH Temperature Measurement Technology cal temperature to the medium being measured. At first glance, this appears quite logical. In practice, this is one of the main...
Open the catalog to page 9Temperature measurement using thermocouples and resistance thermometers Temperature measurement Temperature measurement using thermocouples using resistance thermometers The actual temperature measurement is made at the thermocouple The central component here is the precision resistor, which is inside the thermocouple assembly. With a heat increase, the result- mounted inside the the sensor tip instead of a thermocouple. ing difference in temperature between the different metals results This resistor is traversed by an auxiliary current with anywhere in a measurable electrical voltage, allowing...
Open the catalog to page 10GÜNTHER GmbH Temperature Measurement Technology Normally, thermocouples whose conductor pairs are insulated Most often, a Protection tube has to be utilized to protect the ther- against each other, are applied in pure, dry conditions and up to mocouple from the aggressive environmental conditions inside the certain temperatures without protective fitting. With a fast reaction measuring site. Protective fittings time, quick through heating and minor heat dissipation this approach is - when possible - quite advantageous. Metal protection tubes Ceramic protection tubes Depending on the circumstances,...
Open the catalog to page 1100-TMT Thermocouple assemblies with metal protection tube 00-TMT Thermocouple assemblies with metal protection tube Straight line thermocouple assemblies with metal protection tubes are used, depending on the properties of the protection tube, for common temperature measurements in liquid, gaseous or plastic mediums up to a temperature of 1200°C. The protective fittings of this product line are composed of seam welded or seamlessly drawn metal tubing. Depending on the application, GÜNTHER GmbH has over 40 different, partly high-alloyed materials in a large array of measurements in stock. The...
Open the catalog to page 121 Connection head (s. page 61) A B AUZH BUZH Example of a common implementation in this product line 2 Protection tube (materials) St. 35.8 Mat. No. 1.0305 Heat resistant steel Mat. No. 1.4893 Threaded socket Flange / Counter flange C799 (gas-tight) Aluminum oxide Nominal length Type S Type B Type K Type J Type L Type C Type N Type D Configuration Fast response time: Tapered protection tube Protective sheath diameter: 6-15 mm Individual solutions such as, for example materials, process connectors, accessories, etc. not listed here, are often realisable. Please contact us for further information!...
Open the catalog to page 135 Pages
12 Pages