P158LE

P158LE

P158LE

Product catalog summary
Overview: This document provides technical specifications and operational guidelines for the Doosan Infracore Generator Engine, specifically the P158LE model. It includes details on power ratings, engine data, and various system specifications.
Power Ratings: The engine's power ratings are defined according to ISO 8528 and ISO 3046 standards. Standby power is for emergency use during utility outages, with no overload capability, and is limited to 200 hours per year. Prime power is for variable load applications, allowing unlimited hours per year with a 10% overload capability for short periods.
General Engine Data: The P158LE is a 4-cycle, V-type, 8-cylinder engine with turbocharging and intercooling. It has a displacement of 14.618 liters and a compression ratio of 15:1. The engine's dry weight is 950 kg, and its dimensions are 1,389 x 1,389 x 1,216 mm.
Exhaust and Air Induction Systems: The exhaust system allows a maximum back pressure of 5.9 kPa. The air induction system has specific intake air restrictions depending on the filter condition.
Cooling System: The engine uses a fresh water forced circulation cooling method with a coolant capacity of approximately 80 liters when including the radiator. The maximum water temperature for operation is 103°C.
Lubrication System: The engine employs a force-feed lubrication system with a gear pump. The oil capacity ranges from 17 to 21 liters, and the maximum oil temperature is 120°C.
Fuel System: The engine uses a Bosch in-line pump with an electric governor. It operates on diesel fuel with specific restrictions on fuel inlet and return pressures.
Electrical System: The engine features a 28.5V alternator and a 24V starting motor. The recommended battery capacity is 2 x 200 Ah.
Valve System: The engine has an overhead valve type with specific valve timing and lash settings.
Performance Data: The document provides detailed performance metrics, including specific fuel consumption at various loads and operational conditions for elevated temperatures and altitudes.
Additional Information: The document includes conversion tables and notes that specifications are subject to change without notice.
See more

Catalog excerpts

P158LE-1

DOOSAN INFRACORE GENERATOR ENGINE Gross Engine Output Ratings Definitions The power ratings of Emergency Standby and Prime are in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046. Electric power (kWe) must be considered cooling fan loss, alternator efficiency, altitude derating and ambient temperature. STANDBY POWER RATING is applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. A standby rated engine should be sized for a maximum of an 70% average load factor and 200 hours of operation per year. This includes less than 25 hours per year at the Standby Power rating. PRIME POWER RATING is available for an unlimited number of hours per year in variable load application. Variable load should not exceed a 70% average of the Prime Power rating during any operating period of 24 hours. The Total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload capability is available for a period of 1 hour withing a 12 hour period of operation. Total operating time at the 10% overload power shall not exceed 25 hours per year. ◎ GENERAL ENGINE DATA ㅇEngine Model ㅇEngine Type 4-Cycle, V-type, 8-Cylinder, Turbo charged & intercooled (air to air) ㅇCompression ratio Counter clockwise viewed from Flywheel ㅇFiring order ㅇInjection timing ㅇDry weight ㅇDimension (LxWxH) ㅇFly wheel housing ㅇFly wheel ㅇNumber of teeth on flywheel ◎ ENGINE MOUNTING Maximum Bending Moment at Rear Face to Block ◎ EXHAUST SYSTEM Maximum Back Pressure ◎ AIR INDUCTION SYSTEM Maximum Intake Air Restriction . With Clean Filter Element . With Dirty Filter Element ㅇMax. static pressure after Radiator

 Open the catalog to page 1
P158LE-2

◎ COOLING SYSTEM Water circulation by centrifugal pump on engine. ㅇCooling method Fresh water forced circulation ㅇCoolant capacity Engine Only : Approx. 20 lit, With Radiator(standard) : Approx 80 lit. ㅇCoolant flow rate ㅇWater Temperature - Maximum for standby and Prime - Before start of full load ㅇWater pump Centrifugal type driven by belt ㅇThermostat Type and Range Wax – pellet type, Opening temp. 71°C , Full open temp. 85°C Blower type, Plastic , 915 mm diameter, 7 blade ㅇMax. external coolant system restriction ◎ LUBRICATION SYSTEM Force-feed lubrication by gear pump, lubricating oil cooling...

 Open the catalog to page 2
P158LE-3

◎ VALVE SYSTEM ㅇ Type Overhead valve type Intake 1, exhaust 1 per cylinder ㅇ Valve lashes at cold ㅇ Valve timing Opening -. Intake valve -. Exhaust valve Prime Power Standby Power ㅇGoverned Engine speed ㅇEngine Idle Speed ㅇOver speed limit ㅇGross Engine Power Output ㅇBreak Mean effective pressure MPa ㅇMean Piston Speed ㅇFriction Power ㅇ Specific fuel consumption ㅇFan Power ㅇSound Pressure at 1m from the each side of Cylinder Block (without Fan) The all data and the specific fuel consumption are based on ISO 3046/1, Standard reference conditions are in accordance with 298 K(25˚ Celsius) air temperature,...

 Open the catalog to page 3
P158LE-4

◆ CONVERSION TABLE in. = mm x 0.0394 PS = kW x 1.3596 psi = kg/cm2 x 14.2233 in3 = lit. x 61.02 hp = PS x 0.98635 lb = kg x 2.20462 kW = kcal/sec x 0.239 lb/ft = N.m x 0.737 U.S. gal = lit. x 0.264 kW = 0.2388 kcal/s lb/PS.h = g/kW.h x 0.00162 cfm = m3/min x 35.336 MPa = kPa x 1000 = bar x 10 Doosan Infracore Co., Ltd. 21st Floor, Doosan Tower, 18-12, Euljiro 6-ga, Jung-gu, Seoul, Korea. ※ Specifications are subject to change without prior notice. Printed in April 2014 Large Engine Engineering Team_P158L

 Open the catalog to page 4

All GUCBIR GENERATOR MANUFACTURING CO.LTD. catalogs and technical brochures

  1. 6BTAA5.9-G7

    2  Pages

  2. 6BTAA5.9-G6

    2  Pages

  3. 6BTA5.9-G5

    2  Pages

  4. X3.3-G1

    2  Pages

  5. X2.5 G2

    2  Pages

  6. D1505-E2-BG

    2  Pages

  7. DP222LC

    4  Pages

  8. DP222LB

    4  Pages

  9. DP180LB

    4  Pages

  10. DP180LA

    4  Pages

  11. DP158LD

    4  Pages

  12. DP158LC

    4  Pages

  13. DP126LB

    4  Pages

  14. P126TI-II

    4  Pages

  15. P126TI

    4  Pages

  16. P086TI

    4  Pages

  17. DP086TA

    4  Pages

  18. D1146T

    4  Pages

  19. GB 500

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.