DP222LB

DP222LB

DP222LB

Product catalog summary
Specifications:
The Doosan Infracore Generator Engine, model DP222LB, is a 4-cycle, V-type, 12-cylinder engine that is turbocharged and intercooled. It has a bore and stroke of 128 x 142 mm and a displacement of 21.927 liters. The engine operates with a compression ratio of 15:1 and rotates counterclockwise when viewed from the flywheel. The dry weight of the engine is 1,420 kg, and its dimensions are 1,738 x 1,389 x 1,258 mm.
Power Ratings:
The engine's power ratings are defined according to ISO 8528 and ISO 3046 standards. Standby power is for emergency use during utility outages, with no overload capability, and is limited to 200 hours per year. Prime power is available for unlimited hours with a 10% overload capability for 1 hour within a 12-hour period, not exceeding 500 hours per year at 100% power.
Cooling System:
The engine uses a fresh water forced circulation cooling method with a centrifugal pump. The coolant capacity is approximately 23 liters for the engine only and 114 liters with the radiator. The maximum water temperature for standby and prime is 103°C.
Lubrication System:
The engine employs a fully forced pressure feed lubrication method with a gear-type oil pump. The oil capacity ranges from 27 to 40 liters, and the maximum oil temperature is 120°C.
Fuel System:
The engine uses a Bosch in-line pump with an electric governor and a mechanical feed pump. It operates on diesel fuel oil, with a fuel feed pump capacity of 630 liters per hour.
Electrical System:
The engine features a 27.5V x 45A alternator with a built-in IC voltage regulator. The starting motor is 24V x 7.0 kW, and the recommended battery capacity is 2 x 200 Ah.
Performance Data:
The engine's governed speed is 1500 rpm, with an idle speed of 800 rpm and an overspeed limit of 1650 rpm. The specific fuel consumption varies with load, with 39.2 liters/hr at 25% load and 147.1 liters/hr at 100% load.
Derating:
The engine's maximum power is the standby rating when assessing derate parameters, which are influenced by ambient temperature and altitude.
Additional Information:
The document includes a conversion table for various units and notes that specifications are subject to change without notice.
See more

Catalog excerpts

DP222LB-1

DOOSAN INFRACORE GENERATOR ENGINE Gross Engine Output - without Cooling Fan Net Engine Output - with Cooling Fan Ratings Definitions The power ratings of Emergency Standby and Prime are in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046. Electric power(kWe) should be estimated by considering generator efficiency, cooling fan power loss and power derating due to altitude and ambient temperature. STANDBY POWER RATING is applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. A standby rated engine should be sized for a maximum of an 70% average load factor and 200 hours of operation per year. This includes less than 25 hours per year at the Standby Power rating. PRIME POWER RATING is available for an unlimited of hours per year in variable load application. Variable load should not exceed a 70% average of the Prime Power rating during any operating period of 24 hours. The Total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload capability is available for a period of 1 hour within a 12 hour period of operation. Total operating time at the 10% overload power shall not exceed 25 hours per year. ◎ GENERAL ENGINE DATA ㅇEngine Model ㅇEngine Type 4-Cycle, V-type, 12-Cylinder, Turbo charged & intercooled (air to air) ㅇCompression ratio Counter clockwise viewed from Flywheel ㅇFiring order ㅇInjection timing ㅇDry weight ㅇDimension (LxWxH) ㅇFly wheel housing ㅇFly wheel ㅇNumber of teeth on flywheel ◎ ENGINE MOUNTING ㅇMaximum Bending Moment at Rear Face to Block ◎ EXHAUST SYSTEM ㅇMaximum Back Pressure ◎ AIR INDUCTION SYSTEM ㅇMaximum Intake Air Restriction . With Clean Filter Element . With Dirty Filter Element ㅇMax. static pressure after Radiator

 Open the catalog to page 1
DP222LB-2

◎ COOLING SYSTEM Water circulation by centrifugal pump on engine. ㅇCooling method Fresh water forced circulation ㅇCoolant capacity Engine Only : Approx. 23 lit, With Radiator(*Air On 43°C) : Approx 114 lit. ㅇCoolant flow rate ㅇWater Temperature - Maximum for standby and Prime - Before start of full load ㅇWater pump Centrifugal type driven by belt ㅇThermostat Type and Range Wax – pellet type, Opening temp. 71°C , Full open temp. 85°C Blower type, plastic , 915 mm diameter, 9 blades ㅇMax. external coolant system restriction * Two radiator options are provided, based on allowable maximum Air temperature...

 Open the catalog to page 2
DP222LB-3

◎ VALVE SYSTEM ㅇ Type Overhead valve type Intake 1, exhaust 1 per cylinder ㅇ Valve lashes at cold ㅇ Valve timing Opening -. Intake valve -. Exhaust valve Prime Power Standby Power ㅇGoverned Engine speed ㅇEngine Idle Speed ㅇOver speed limit ㅇGross Engine Power Output ㅇBreak Mean effective pressure ㅇMean Piston Speed ㅇFriction Power ㅇSpecific fuel consumption ㅇFan Power ㅇSound Pressure at 1m from the each side of Cylinder Block (without Fan) The all data and the specific fuel consumption are based on ISO 3046/1, Standard reference conditions are in accordance with 298 K(25˚ Celsius) air temperature,...

 Open the catalog to page 3
DP222LB-4

◎ DERATING FROM ISO 3046 STANDARD CONDITIONS The maximum power is the STANDBY rating when assessing derate prameters. Ambient temperature is air inlet temperature. Derate(%) (Ambient Temp) Derate(%) 35% ◆ CONVERSION TABLE in. = mm x 0.0394 PS = kW x 1.3596 psi = kg/cm2 x 14.2233 in3 = lit. x 61.02 hp = PS x 0.98635 lb = kg x 2.20462 kW = kcal/sec x 0.239 lb/ft = N.m x 0.737 U.S. gal = lit. x 0.264 kW = 0.2388 kcal/s lb/PS.h = g/kW.h x 0.00162 cfm = m3/min x 35.336 MPa = kPa x 1000 = bar x 10 Doosan Infracore Co., Ltd. 21st Floor, Doosan Tower, 18-12, Euljiro 6-ga, oor, ower, 18ulj Jung-gu, Seoul,...

 Open the catalog to page 4

All GUCBIR GENERATOR MANUFACTURING CO.LTD. catalogs and technical brochures

  1. 6BTAA5.9-G7

    2  Pages

  2. 6BTAA5.9-G6

    2  Pages

  3. 6BTA5.9-G5

    2  Pages

  4. X3.3-G1

    2  Pages

  5. X2.5 G2

    2  Pages

  6. D1505-E2-BG

    2  Pages

  7. DP222LC

    4  Pages

  8. DP180LB

    4  Pages

  9. DP180LA

    4  Pages

  10. DP158LD

    4  Pages

  11. DP158LC

    4  Pages

  12. P158LE

    4  Pages

  13. DP126LB

    4  Pages

  14. P126TI-II

    4  Pages

  15. P126TI

    4  Pages

  16. P086TI

    4  Pages

  17. DP086TA

    4  Pages

  18. D1146T

    4  Pages

  19. GB 500

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.