DP180LB

DP180LB

DP180LB

Product catalog summary
Engine Specifications
Model: DP180LB
Type: 4-Cycle, V-type, 10-Cylinder, Turbocharged & Intercooled
Bore x Stroke: 128 x 142 mm
Displacement: 18.273 liters
Compression Ratio: 15:1
Rotation: Counterclockwise from Flywheel
Firing Order: 1-6-5-10-2-7-3-8-4-9
Injection Timing: 21˚±1˚ BTDC @ 1800 rpm, 19˚±1˚ BTDC @ 1500 rpm
Dry Weight: 1,250 kg (with Fan)
Dimensions (LxWxH): 1,594 x 1,389 x 1,223 mm
Power Ratings
Standby Power: 1500rpm (50Hz) - 612/832 kWm/PS, 1800rpm (60Hz) - 661/899 kWm/PS
Prime Power: 1500rpm (50Hz) - 596/810 kWm/PS, 1800rpm (60Hz) - 637/866 kWm/PS
Standby Power Rating: For emergency power during utility outages, no overload capability, max 70% average load factor, 200 hours/year.
Prime Power Rating: Unlimited hours/year, variable load, max 70% average load, 10% overload for 1 hour within 12 hours, max 500 hours/year at 100% power.
Cooling System
Method: Fresh water forced circulation
Coolant Capacity: Engine Only - Approx. 21 liters, With Radiator - Approx. 91 liters
Flow Rate: 660 liters/min @ 1800 rpm, 550 liters/min @ 1500 rpm
Max Water Temperature: 103°C
Thermostat: Wax-pellet type, Opening temp. 71°C, Full open temp. 85°C
Cooling Fan: Blower type, 915 mm diameter, 7 blades
Lubrication System
Method: Fully forced pressure feed
Oil Pump: Gear type driven by crank-shaft gear
Oil Capacity: Max. 34 liters, Min. 23 liters
Lub Oil Pressure: Idle Speed - Min 100 kPa, Governed Speed - Min 250 kPa
Max Oil Temperature: 120°C
Fuel System
Injection Pump: Bosch in-line "P" type
Governor: Electric type
Fuel Filter: Full flow, cartridge type with water drain valve
Fuel Type: Diesel fuel oil
Electrical System
Battery Charging Alternator: 27.5V x 45A
Starting Motor: 24V x 7.0 kW
Battery Voltage: 24V
Battery Capacity: 2 x 200 Ah (recommended)
Performance Data
Governed Engine Speed: 1500 rpm
Idle Speed: 800 rpm
Over Speed Limit: 1650 rpm
Specific Fuel Consumption: 25% load - 38.6 liters/hr, 50% load - 71.2 liters/hr, 75% load - 103.8 liters/hr, 100% load - 136.4 liters/hr
Derating Information
Derating is based on altitude and ambient temperature, with specific derate percentages provided for various conditions.
Conversion Table
Includes conversions for units such as in. to mm, PS to kW, psi to kg/cm², etc.
Additional Notes
Specifications are subject to change without prior notice.
See more

Catalog excerpts

DP180LB-1

DOOSAN INFRACORE GENERATOR ENGINE Gross Engine Output - without Cooling Fan Net Engine Output - with Cooling Fan Ratings Definitions The power ratings of Emergency Standby and Prime are in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046. Electric power(kWe) should be estimated by considering generator efficiency, cooling fan power loss and power derating due to altitude and ambient temperature. STANDBY POWER RATING is applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. A standby rated engine should be sized for a maximum of an 70% average load factor and 200 hours of operation per year. This includes less than 25 hours per year at the Standby Power rating. PRIME POWER RATING is available for an unlimited of hours per year in variable load application. Variable load should not exceed a 70% average of the Prime Power rating during any operating period of 24 hours. The Total operating time at 100% Prime Power shall not exceed 500 hours per year. A 10% overload capability is available for a period of 1 hour within a 12 hour period of operation. Total operating time at the 10% overload power shall not exceed 25 hours per year. ◎ GENERAL ENGINE DATA ㅇEngine Model ㅇEngine Type 4-Cycle, V-type, 10-Cylinder, Turbo charged & intercooled (air to air) ㅇCompression ratio Counter clockwise viewed from Flywheel ㅇFiring order ㅇInjection timing ㅇDry weight ㅇDimension (LxWxH) ㅇFly wheel housing ㅇFly wheel ㅇNumber of teeth on flywheel ◎ ENGINE MOUNTING ㅇMaximum Bending Moment at Rear Face to Block ◎ EXHAUST SYSTEM ㅇMaximum Back Pressure ◎ AIR INDUCTION SYSTEM ㅇMaximum Intake Air Restriction . With Clean Filter Element . With Dirty Filter Element ㅇMax. static pressure after Radiator

 Open the catalog to page 1
DP180LB-2

◎ COOLING SYSTEM Water circulation by centrifugal pump on engine. ㅇCooling method Fresh water forced circulation ㅇCoolant capacity Engine Only : Approx. 21 lit, With Radiator(*Air On 43°C) : Approx 91 lit. ㅇCoolant flow rate ㅇWater Temperature - Maximum for standby and Prime - Before start of full load ㅇWater pump Centrifugal type driven by belt ㅇThermostat Type and Range Wax – pellet type, Opening temp. 71°C , Full open temp. 85°C Blower type, plastic , 915 mm diameter, 7 blades ㅇMax. external coolant system restriction * Two radiator options are provided, based on allowable maximum Air temperature...

 Open the catalog to page 2
DP180LB-3

◎ VALVE SYSTEM ㅇ Type Overhead valve type Intake 1, exhaust 1 per cylinder ㅇ Valve lashes at cold ㅇ Valve timing Opening -. Intake valve -. Exhaust valve Prime Power Standby Power ㅇGoverned Engine speed ㅇEngine Idle Speed ㅇOver speed limit ㅇGross Engine Power Output ㅇBreak Mean effective pressure ㅇMean Piston Speed ㅇFriction Power ㅇSpecific fuel consumption ㅇFan Power ㅇSound Pressure at 1m from the each side of Cylinder Block (without Fan) The all data and the specific fuel consumption are based on ISO 3046/1, Standard reference conditions are in accordance with 298 K(25˚ Celsius) air temperature,...

 Open the catalog to page 3
DP180LB-4

◎ DERATING FROM ISO 3046 STANDARD CONDITIONS The maximum power is the STANDBY rating when assessing derate prameters. Ambient temperature is air inlet temperature. Derate(%) (Ambient Temp) (Ambient Temp) ◆ CONVERSION TABLE in. = mm x 0.0394 PS = kW x 1.3596 psi = kg/cm2 x 14.2233 in3 = lit. x 61.02 hp = PS x 0.98635 lb = kg x 2.20462 kW = kcal/sec x 0.239 lb/ft = N.m x 0.737 U.S. gal = lit. x 0.264 kW = 0.2388 kcal/s lb/PS.h = g/kW.h x 0.00162 cfm = m3/min x 35.336 MPa = kPa x 1000 = bar x 10 Doosan Infracore Co., Ltd. 21st Floor, Doosan Tower, 18-12, Euljiro 6-ga, Jung-gu, Seoul, Korea. ※ Specifications...

 Open the catalog to page 4

All GUCBIR GENERATOR MANUFACTURING CO.LTD. catalogs and technical brochures

  1. 6BTAA5.9-G7

    2  Pages

  2. 6BTAA5.9-G6

    2  Pages

  3. 6BTA5.9-G5

    2  Pages

  4. X3.3-G1

    2  Pages

  5. X2.5 G2

    2  Pages

  6. D1505-E2-BG

    2  Pages

  7. DP222LC

    4  Pages

  8. DP222LB

    4  Pages

  9. DP180LA

    4  Pages

  10. DP158LD

    4  Pages

  11. DP158LC

    4  Pages

  12. P158LE

    4  Pages

  13. DP126LB

    4  Pages

  14. P126TI-II

    4  Pages

  15. P126TI

    4  Pages

  16. P086TI

    4  Pages

  17. DP086TA

    4  Pages

  18. D1146T

    4  Pages

  19. GB 500

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.