TPC/LPD-100-Xs

TPC/LPD-100-Xs

TPC/LPD-100-Xs

Product catalog summary
Description: The TPC/LPD-100-XS series is a range of AC/DC switching power supplies with a rated output power of 90-110.4W. It operates within an input voltage range of 90-264VAC and offers multiple output voltages including 5V, 12V, 15V, 24V, 28V, 36V, and 48V. These power supplies are characterized by high reliability, precision, efficiency, and a compact size, eliminating the need for an external heat sink. They feature protections against short circuit, overload, and over-voltage, making them suitable for use in telecommunications, industrial control, data acquisition, and other electronic systems.
Output Characteristics: The power supplies have specific ripple and noise levels, with output adjustment ranges provided for each voltage. Voltage regulation accuracy is ±3% for 5V and ±1% for other voltages, with line and load regulation at ±0.5% and ±1.0% respectively. The temperature coefficient is ±0.03%/°C, and the setup and hold-up times are specified for different input conditions.
Features: The series supports a universal AC input range of 90VAC-264VAC and includes a 100% full load burn-in test. It operates within a temperature range of -30°C to 70°C and complies with RoHS standards. The design incorporates long-life electrolytic capacitors and can withstand 300VAC for 5 seconds.
Selection Guide: The document provides a detailed selection guide with part numbers, input and output specifications, efficiency ratings, and power ratings for each model in the series.
Input Characteristics: The input voltage range is 90Vac~264Vac or 120-370VDC, with a maximum input voltage of 300Vac. The frequency range is 47Hz~63Hz, and the input current is specified for different voltages. Standby power consumption is less than 0.5W.
Protection: The series includes over-power, over-voltage, and over-load protections, all with auto recovery features. Output short circuit protection is also provided.
Environmental Characteristics: Operating conditions include a temperature range of -30°C to 70°C and humidity levels of 20%~90%RH. Storage conditions are specified as -40°C to 85°C with 10%~95%RH. The units can withstand vibrations and pulses as specified.
Safety & EMC Standards: The series meets various safety standards including UL60950-1 and TUV EN60950-1. It also complies with EMC emission and immunity standards.
Other Characteristics: The cooling method is free air flow, with dimensions of 129*97*30mm and a net weight of 0.29kg. The MTBF is 200,000 hours at 25°C.
See more

Catalog excerpts

TPC/LPD-100-Xs-1

TPC/LPD-100-XS series 100W Wide input AC/DC switching power supply The rated output power of TPC/LPD-100-XS series is 90-110.4W, input voltage range: 90-264VAC, output voltage : 5V, 12V,15V,24V,28V,36V,48V,High reliability, precision,effificency , ultra-small size, no external heat sink required, stable output voltage and etc, with short circuit, over-load,over-voltage protection, Widely used in telecommunications, industrial control, instrument, data acquisition, signal control , New Energy, Security,and other electronic systems. High reliability,effificency ,long life All using 105C long-life electrolytic capacitors Low standby power consumptions.5W Can bear 300VAC for 5s, 1U low profile SELECTION GUIDE Input Part Number Range values Current Ratec range(A) power('

 Open the catalog to page 1
TPC/LPD-100-Xs-2

TPC/LPD-100-XS series INPUT characteristics! Output short circuit protection Parameter 110%~180% of rated power, Hiccup mode, auto recovery 115%~150% of rated output voltage, constant voltage, auto recovery 110%~180% of rated current, Hiccup mode, auto recovery Long-term mode, Auto recovery ENVIRONMENT CHARACTERISTICS Conditions Storage Temp. & Humi. Parameter -30"C~70"C; 20%~90%RH No condensing (refer to the derating curve) -40"C~85"C; 10%~95%RH No condensing 10 ~ 500Hz, 5G 10min./1 cycle, period for60min. each along X,Y, Z axes 20G/11 mS pulse ,3 times at each X,Y,Z axes 5000m SAFETY&EMC STANDARDS...

 Open the catalog to page 2
TPC/LPD-100-Xs-3

Mounting Position Customer plate 1, Dimensional Unit: mm 2,Unmarked Tolerance is GB/T 1804-m 3, Choose the best installation method.SMPS Cover Assemble Screw Remarks: 1. For safety purpose, the length of screw inside the power supply case shall comply with the above table (refer the right drawing) 1, Instruction of the AC Input Connectors Part number

 Open the catalog to page 3
TPC/LPD-100-Xs-4

TPC/LPD-100-XS series BLOCK DIAGRAM DERATING CURVE MODEL SELECTION S: Single ouput; D: Dual output Output voltage Delimiter Rated output power Delimiter Series Delimiter Type Brand TOPPOWER

 Open the catalog to page 4

All Guangzhou Top Power Electronics Technology Co.,Ltd catalogs and technical brochures

  1. NDR-U240-XS

    6  Pages

  2. 20SDR-360-XS

    6  Pages

  3. TPC/PD-50-XS

    4  Pages

  4. TPC/NE-350-XS

    4  Pages

  5. TPC/NE-50-XS

    4  Pages

  6. TPC/LR150-XS

    4  Pages

  7. TPC/lr-50-Xs

    5  Pages

  8. TPC/LR-35-Xs

    5  Pages

  9. TP15DC Series

    4  Pages

  10. TP15DD Series

    4  Pages

  11. TP30DG Series

    4  Pages

  12. TP40DG Series

    4  Pages

  13. TP20DD Series

    4  Pages

  14. TPTA Series

    4  Pages

  15. TP05AR Series

    4  Pages

  16. TP05AS Series

    4  Pages

  17. TP10AT Series

    4  Pages

  18. TP10DB series

    2  Pages

  19. TP12DC series

    4  Pages

  20. TP102MV

    2  Pages

  21. TP250MV

    2  Pages

  22. TPA2

    3  Pages

  23. TPC LR-50-XS

    5  Pages

  24. TP05DA Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.