Description: The TP78Lxx-1 series are switching regulators designed to replace TP78xx linear regulators and LDOs. They offer high efficiency up to 97%, eliminating the need for heat sinks. These regulators are suitable for industrial control, instrumentation, and electric power applications, providing a wide input non-isolated and regulated single output.
Output Characteristics: The series features an output voltage accuracy of ±2% to ±3% at full load, line regulation of ±0.2% to ±0.4%, and load regulation of ±0.4% to ±0.6%. Ripple and noise are measured at 25 to 35 mVp-p. The devices include continuous short circuit protection with automatic recovery and thermal shutdown at 150°C. The switching frequency ranges from 280 to 450 KHz, with output current limits varying by output voltage.
Common Specifications: Operating temperature ranges from -40°C to 85°C, with power derating above 71°C. The storage temperature ranges from -55°C to 125°C. The devices are cooled by free air convection and housed in a plastic case (UL94-V0). The MTBF is 2000 k hours at 25°C.
Features: The series is ROHS compliant, offers short circuit protection, thermal shutdown, and low ripple noise. It comes in a SIP package with no heat sink required and follows an industry-standard pinout.
Selection Guide: The document provides a detailed selection guide with part numbers, input voltage ranges, output voltages, and efficiencies. For example, the TP78L1.5-1 operates with an input voltage range of 4.75 to 26 VDC and provides an output of 1.5 VDC at 1000 mA with an efficiency of 80%.
Temperature Derating and Capacitor Table: The document includes temperature derating graphs and an external capacitor table specifying the required ceramic capacitors for each part number.
Standard Application Circuit: The application circuit requires C1 and C2 capacitors to be placed close to the converter pins. The capacitance can be increased if necessary, and tantalum or low ESR electrolytic capacitors may be used.
Mechanical Dimensions and Pin Connections: The document provides detailed mechanical dimensions and pin connections for the SIP package, including recommended footprint details and tube outline dimensions.
See more

Catalog excerpts

TP78Lxx-1 non-isolated dc-dc converter-1

Wide Input Non-Isolated & Regulated Single Output TP78LXX-1 series switching regulators are ideal replacement for TP78xx linear regulators and LDOs. The efficiency of up to 97% means that very little energy is wasted as heat so there is no need for any heat sinks with their additional space and mounting costs. They are widely used in industrial control, instrumentation, and electric power applications. The above part number with "L" Suffix are 90” bent pins power converters, for example TP78L1.5-1L. OUTPUT CHARACTERISTICS Conditions 100% full load Vin=min. to max, at full load 10% to 100% load 20MHz bandwidth Parameter Conditions Min Output voltage accuracy Line regulation Load regulation Ripple & Noise Short circuit input power Short circuit protection Thermal shutdown Switching frequency 100% full load 280 Output current limit Output current limit Quiescent current Temperature coefficient Max capacitance load All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. Internal IC junction 100% full load Vin= min. to max.(at full load) Vout:1.5V~3.3V Vin= min. to max.(at full load) Vout:5V~15V -40"C~+85"C ambient Continuous, automatic recovery 150 Units % mvp-p W C KHz mA mA mA %/C pF COMMON SPECIFICATIONS Parameter Storage humidity Operating temperature Operating case temp Storage temperature Lead temperature Cooling Case material MTBF Weight Conditions Power derating (above 71°C) 1.5mm from case for 10 seconds 25"C(MIL-HDBK-217F)

 Open the catalog to page 1
TP78Lxx-1 non-isolated dc-dc converter-2

EXTERNAL CAPACITOR TABLE TEMPERATURE DERATING GRAPHS 120 Temperature Derating Graph 1. C1 and C2 are required and should be fitted close to the converter pins. 2. The capacitance of C1 ,C2 sees external capacitor table, it can be increased properly if required, and tantalum or low ESR electrolytic capacitors may also suffice. 3. No parallel connection or plug and play. 1.Efficiency and Output Voltage Ripple Test Copper strip Copper strip 2. 2.Start-up and Load Transient Response Test

 Open the catalog to page 2
TP78Lxx-1 non-isolated dc-dc converter-3

TP78Lxx-1 Series MECHANICAL DIMENSIONS 90˚ bent pins power converters(part number with "L" Suffix) 9.00 bottom view bottom view All dimensions in mm ±0.25.All pins on a 2.54mm pitch. RECOMMENDED FOOTPRINT DETAILS 90˚ bent pins power converters(part number with "L" Suffix) Unless otherwise stated all dimensions in mm ±0.5mm. Unless otherwise stated all dimensions in mm ±0.5mm. TUBE OUTLINE DIMENSIONS 11.2 90˚ bent pins power converters (part number with "L" Suffix) Unless otherwise stated all dimensions in mm ±0.5mm. L=520mm ±2mm Packaging quantity:44PCS L=220mm ±2mm Packaging quantity:17PCS

 Open the catalog to page 3

All Guangzhou Top Power Electronics Technology Co.,Ltd catalogs and technical brochures

  1. NDR-U240-XS

    6  Pages

  2. 20SDR-360-XS

    6  Pages

  3. TPC/PD-50-XS

    4  Pages

  4. TPC/NE-350-XS

    4  Pages

  5. TPC/NE-50-XS

    4  Pages

  6. TPC/LR150-XS

    4  Pages

  7. TPC/lr-50-Xs

    5  Pages

  8. TPC/LR-35-Xs

    5  Pages

  9. TP15DC Series

    4  Pages

  10. TP15DD Series

    4  Pages

  11. TP30DG Series

    4  Pages

  12. TP40DG Series

    4  Pages

  13. TP20DD Series

    4  Pages

  14. TPTA Series

    4  Pages

  15. TP05AR Series

    4  Pages

  16. TP05AS Series

    4  Pages

  17. TP10AT Series

    4  Pages

  18. TP10DB series

    2  Pages

  19. TP12DC series

    4  Pages

  20. TP102MV

    2  Pages

  21. TP250MV

    2  Pages

  22. TPA2

    3  Pages

  23. TPC LR-50-XS

    5  Pages

  24. TP05DA Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.