1. Catalogs
  2. Guangzhou Biaoji Packaging Equipment Co., Ltd.
  3. N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)
video corpo

N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)

N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)

N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)

Product catalog summary
Introduction
The N530 2.0 Gas Transmission Tester utilizes the differential pressure method for testing gas permeability in various materials such as films, sheets, and packages. It is designed with high-precision sensors and automatic pressure maintenance technology, ensuring high accuracy and efficiency in testing gas transmission rates across a wide range of materials.

Test Principle
The differential pressure method involves placing a sample between two chambers, creating a pressure difference that allows gas to permeate through the sample. The system calculates the gas permeability based on pressure changes in the lower chamber.

Standards
The tester complies with standards such as ISO 2556, ISO 15105-1, ASTM D1434, and others, ensuring its applicability in various industries.

Specifications
  • Test Range: 0.02~50000 cm³/(m²·24 h·0.1 MPa)
  • Resolution: 0.0001 cm³/(m²·24 h·0.1 MPa)
  • Temperature Control: 15~60℃ with ±0.1℃ accuracy
  • Vacuum Degree: <10 Pa
  • Test Gas: O2, CO2, N2, etc.
  • Sample Size: Φ110 mm, Thickness ≤2 mm
  • Dimensions: 690 mm x 620 mm x 390 mm, Weight: 55 kg

Features
  • Patented technology for precise pressure maintenance and high testing efficiency.
  • Supports simultaneous testing of three samples with independent operation and data.
  • Compatible with various gases and materials, including bottles and bags.
  • Real-time data visualization and customizable high-pressure testing.
  • Intelligent operating system with audit trail functionality and multi-level user permissions.

Applications
The tester is suitable for a wide range of materials including plastic films, sheets, paper, medicinal patches, hygiene products, and various packaging types. It can test gases like oxygen, carbon dioxide, nitrogen, and more.

Factory Configuration
Standard configuration includes power and communication lines, special tools, and accessories. Optional items include a computer and measurement certificate.

Service Commitment
GBPI offers free technical support, a one-year warranty, software upgrades, and training. They also provide calibration services and have a policy for instrument replacement.

For more information, visit the GBPI official website at www.gbpitester.com.
See more

Catalog excerpts

N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-1

Differential Pressure Method Gas Transmission Tester N530 2.0 Introduction N530 2.0 is based on the test principle of differential pressure method, It's designed with reference to ISO 2556 and other standards. Adopt high-precision pressure sensor and automatic pressure difference keeping technology, high test accuracy. It is suitable for the gas permeability test of films, sheets, papers, packages and related materials in the fields of food, medicine, medical equipment, daily chemicals, photovoltaic electronics, etc. It provides a wide range and high-efficiency gas transmission rate test of high, medium and low gas barrier materials. Test Principle According to the principle of differential pressure method. Place the processed sample between the upper and lower chambers, use a vacuum pump to evacuate the entire gas circuit system, and then add an experimental gas of an atmospheric pressure to the upper chamber to form a constant pressure difference between the upper and lower chambers. Under the pressure gradient, the gas permeates from the upper chamber to the lower chamber through the membrane, then the system can calculate the barrier performance parameters such as the gas permeability of the sample through the pressure change of the lower chamber. Add.: No. 3, Linjiang Road, Huangpu District, Guangzhou, Guangdong Province, China

 Open the catalog to page 1
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-2

Standards Chinese Pharmacopoeia 2025 Edition, "4007 Determination of Gas Permeability of Pharmaceutical Packaging Materials", GB/T 1038.1, ISO 2556, ISO 15105-1, ASTM D1434, JIS K7126-1, YBB 00082003 Add.: No. 3, Linjiang Road, Huangpu District, Guangzhou, Guangdong Province, China Tel: 020-8615 3789, 8615 3790 Web: www.gbpitester.com

 Open the catalog to page 2
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-3

Sample Size Patented automatic differential pressure maintenance technology automatically maintains the pressure difference across the sample (the differential pressure is adjustable). It features a built-in high-precision pressure sensor with a resolution of 0.01 Pa, offering excellent stability and a low failure rate. A semiconductor cooling chip provides bidirectional automatic temperature control with an accuracy of 0.1 °C. An original high-reliability vacuum pump with an ultimate pressure of 0.05 Pa offers high vacuum efficiency and low noise. A brand-new pneumatic gas path control system...

 Open the catalog to page 3
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-4

It features data fitting at any temperature, capable of fitting parameters such as gas permeability of test materials at different temperatures. Customizable high-pressure testing is available, supporting pressure tests within the range of 0~300 kPa, enabling precise pressure holding. Excellent appearance, convenient operation, and real-time visualized curves. The product features an artistic design from an ergonomic and aesthetic perspective, with a refined 3D-printed shell, smooth lines, and a stylish, unique look. Fully automatic operation, one-button testing, automatic judgment, and automatic...

 Open the catalog to page 4
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-5

Application Various plastic films (PP/PET/PE/PVC/BOPP/CPP, etc.), plastic composite films, paper-plastic composite films, metal Films composite films, co-extruded films, aluminized films, degradable packaging films (PLA/PBAT/PBS etc.) and other membranous materials Solid medical hard sheet (PP/PVC/PTP, etc.), metal composite sheet, rubber sheet and other sheet materials Coated paper, carbon paper, silicone paper, aluminized paper, paper-aluminum-plastic composite sheet and other paper, cardboard Medicinal patch, Medical plaster treatment patch, warm patch, dysmenorrhea warmer patch Sanitary napkins,...

 Open the catalog to page 5
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-6

Factory configuration Standard Note: GBPI has always been committed to the innovation and improvement of product performance and function. For this reason, product technical specifications and appearance will also be changed accordingly. The above situation will not be notified. GBPI reserves the right of modification and final interpretation. Add.: No. 3, Linjiang Road, Huangpu District, Guangzhou, Guangdong Province, China Tel: 020-8615 3789, 8615 3790 Web: www.gbpitester.com

 Open the catalog to page 6
N530 2.0 Differential Pressure Method Gas Transmission Tester Introduction A3(20251031)-7

GBPI (Guangzhou Biaoji Packaging Equipment Co., Ltd.) was established in 2002 and is located in Guangzhou Economic Development Zone. It is an enterprise integrating R&D, production, sales of packaging testing instruments, packaging equipment, modified atmosphere refrigerator and other products, and providing third-party testing and reference material calibration services. It is committed to providing comprehensive, professional, high-quality products and technical services for the packaging, food, medicine, testing and other industries. Write industry standards with quality and become a leader...

 Open the catalog to page 7

All Guangzhou Biaoji Packaging Equipment Co., Ltd. catalogs and technical brochures

  1. GB-QL-720A

    7  Pages

  2. 9802-K

    1  Page

  3. GBN702

    1  Page

  4. GBN701

    1  Page

  5. GB-BF20010

    1  Page

  6. GB-XF1000

    1  Page

  7. GB-PF400H

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.