1. Catalogs
  2. Guangzhou Biaoji Packaging Equipment Co., Ltd.
  3. GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)
video corpo

GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)
1 /15Pages

GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)

GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)
1 /15Pages

Catalog excerpts

GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-1

Ozone Aging Test Chamber (Dynamic Stretching) GB-OCY-150M

 Open the catalog to page 1
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-2

Technical specification 1 Product performance 1.1 Item Ozone aging test chamber (Dynamic) 4.0KW Ozone in the atmosphere is very little, while it’s a major factor in rubber cracking, the product simulate and enhance atmospheric ozone condition to study the role of ozone on the rubber, and to rapid identificate and evaluate rubber resistance for ozone aging and anti-ozone agent protection. According to“GB / T7762-2003 Test Method for Static Tensile Test of Ozone Resistance Cured Rubber or Thermoplastic Rubber”,“GB / T2951.21-2008 General Test Method for Insulation and Sheathing Material of Cable”,“GB...

 Open the catalog to page 2
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-3

Temperature range: RT+10 ℃~ 60 ℃ (Adjustable, ozone will decompose when temp. above 60 ℃) Temperature fluctuation: ±0.5℃ Accuracy of Tem. Distribution: ±2.0℃ Max. Tep. of Ozone: 60℃ (When the temperature is above 60 ℃, ozone decomposition rate will get rapid self-decomposition. Heating time: around 20min from RT to 60 ℃ Humidity range: ±3.0%. Humidity fluctuation: ±2.0%. Ozone concentration accuracy: 50~1000pphm (adjustable, low viscosity) Air flow amount: 20~70L/min Air flow rate: 12~16mm/s Revolving speed of sample holder Ozone Accuracy: ±5.0% F.S Ozone fluctuation: ±2.5pphm Specimen fixture:...

 Open the catalog to page 3
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-4

With observation window (W220xH250mm), lights above the At both ends of the sample to be fixed with a clamp under the required elongation, the longitudinal direction of the specimen shall be substantially parallel to the direction of air flow when in contact with ozonized air. b) Clamps shall be made of a material (eg aluminum) which does not readily decompose ozone. 3.4 Allow the sample to rotate at a speed between (20 ^ -25) mm / s, in a plane perpendicular to the dry gas flow, with each sample dynamic-type only) moving continuously along the same path. d) The time of one revolution of the...

 Open the catalog to page 4
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-5

light switch button With a stainless steel SUS # 304 shelf turntable One φ50mm lead hole:, and with a hole cover and silicone Horizontal mounting brackets 4 pcs There is a drainage hole in the back of the machine to facilitate the drainage of condensate; (8mm in diameter) f) Three-phase five-wire cable (four-core cable + protective grounding wire) 1 pc, (three meters long). 4 Air circulation regulation FLOW THROW air supply; horizontal diffusion vertical heat 4.1 Adjustment mode exchange in arc cycle. Power-saving Heating system Fin - type heat pipe, stainless steel electric heater for heating....

 Open the catalog to page 5
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-6

operating conditions of the refrigerator according to the test conditions. Europe and the United States well-known brands, low-temperature Refrigeration full-compact compressor. (France; Tecumseh ) Finned multi - stage automatic load capacity adjustment. (Japan; Saginomiya) Air cooled condenser. (Japan; Shuangling) Refrigeration system with capacity automatic control. Environmental protection refrigerant R404 (ozone depletion index is 6.10. Accessories Nitrogen protection welding, two-stage rotary vane pump vacuum, to ensure that the internal cooling system is clean, and the bottom of compressor...

 Open the catalog to page 6
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-7

Adopt voltage silent discharge tube to generate ozone 7.1 Ozone generator 7.2 Ozone sensor British imported ozone concentration sensor, to achieve precise control 7.3 Ozone exhaust system After the experiment is finished, ozone in the chamber can be discharged to the outdoor through the special exhaust fan and air hose. regulator High-accuracy glass flow rotor with accurate adjustment 8 Control system Temperature sensor with platinum DIN PT-100Ω, Imported Korean TEMI880 color LCD 8.2 Controller interface controller to provide large vision, with screen lock (LOCK) function, and Chinese-English...

 Open the catalog to page 7
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-8

Display: 128 * 128 points, touch screen operation Backlight: CFL (Cold Cathode Fluorescent Lamp) Multi-group PID control output: temperature * 6, humidity * Control response time: 0.1s 12 groups of dry contacts, enable equipment to upgrade Data Memory Save: Non-volatile RAM Program segment number 100STEP, program group 100 Optional online and remote control (optional accessories) 485/232 interface for data printing, storage. Control method: heat balance thermostat humidity mode Language: Chinese / English display Use graph control software screen dialogue, with screen directly touch options:...

 Open the catalog to page 8
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-9

Security protection devices Compressor overheat protection switch b) Compressor high-voltage protection switch Heater surface temperature over-temperature protection heater short-circuit, overload protection device Circulating motor overheating protection Condenser fan overheat protection compressor over-current protection switch High temperature, low temperature, over-temperature Reverse phase, phase protection devices, No-fuse switch overload protection. Smoke alarm, blackout protector. Line fuses and full-sheath terminals 10 Accessories 10.1. Shelving 10.2. Shelving rail SUS304 stainless steel...

 Open the catalog to page 9
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-10

manual 10.11. Warranty card 11 After-sales service commitment a) Our technical service department is responsible for after-sales service to share you with professional technical servies including operation, maintenance. b) Technical personnel on-site or telephone guidance for installation, free training available for those who purchased our machines and including basic catering accommodation. c) Upon received service requirements from customer, within 24 hours (time difference) solutions will be provided for customers; for home services that need pay for the freight charge, catering accommodation...

 Open the catalog to page 10
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-11

a) It’s best to equip with drainage drain or drain pipe near the test chamber. b) Equip with air or power switch in corresponding capacity (ie 30A) on the site wall. c) Keep ground to be flat, well-ventilated, non-flammable and explosive corrosive gases and dust. TEMI controller material Tecumse Parts Temp. Refrigerant valve anti-explosion glass Evaporator regulator Overheat protector

 Open the catalog to page 11
GB-OCY-150M Ozone Aging Test Chamber (Dynamic Stretching)-12

Check valve Heating relay Time relay valve Pressure Water pump Circulation motor Temp. & humid. sensor Solid state Thermal overload

 Open the catalog to page 12

All Guangzhou Biaoji Packaging Equipment Co., Ltd. catalogs and technical brochures

  1. GB-QL-720A

    7  Pages

  2. 9802-K

    1  Page

  3. GBN702

    1  Page

  4. GBN701

    1  Page

  5. GB-BF20010

    1  Page

  6. GB-XF1000

    1  Page

  7. GB-PF400H

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.