video corpo

9802-K

9802-K

Product catalog summary
Introduction
The 9802-K Ethylene Oxide Gas Chromatography is designed with a reasonable structure, offering stable and reliable performance. It is easy to operate and maintain, making it suitable for use in various sectors such as petroleum, chemical industry, pesticide, medicine, hygiene, commodity inspection, environmental protection, and education. It is used to detect organic solvents, solvent residues in printed packaging materials, and the purity or content of a single solvent.

Product Features
The device is economical and practical, providing excellent performance and quality. It features an adjustable gas circuit pressure and stable flow, with multiple gas circuit systems including nitrogen, hydrogen, air, exhaust, shunt, and cleaning. The LCD screen displays temperature in real-time, and the cellular overall structure design facilitates easy installation and maintenance. It includes an advanced noise-resistant system for quiet operation, over-temperature protection, program protection, and circuit protection for double insurance. The data workstation offers professional software support and powerful data analysis functions, displaying working conditions and chromatogram curves that can be zoomed and moved. It can export professional test reports in PDF format. The manual button switch is convenient for sampling, and the detector and baseline calibration are easy to operate.

Technical Specifications
  • Detector: Hydrogen flame detector (FID), optional for others.
  • Column oven size: 240×210×240mm.
  • Temperature range: 4℃ to 450℃, adjustable in 1℃ increments.
  • Temperature controlling accuracy: 0.1%.
  • Head space: 1℃.
  • Hydrogen generator (optional): Oil-free air generator with degreasing and water purification equipment, 3L/min.
  • Temperature gradient: Gas production 300ml/min, purity 99.999%.
  • Standard material: Ethylene oxide standard workstation.
  • Capillary injection system: Dual-channel, anti-control workstation, split/splitless with diaphragm cleaning function.

Contact Information
Address: NO.1 Minghua 3 Street, Jinxiu Road, Economic Development Zone, Guangzhou, China
Tel: 86-20-86153790, 86-20-86153742
Fax: 86-20-82087405
Website: https://www.gbpitester.com
Email: [email protected]
See more

Catalog excerpts

9802-K-1

Specifications Temperature range Temperature controlling accuracy Temperature gradient Air generator (optional) Hydrogen generator (optional) Nitrogen cylinder and pressure reducing valve Standard material Item Technical Specification Detector hydrogen flame detector(FID) (optional for others) Head space 20 Bits Column oven size 240X210X240mm 1C Oil-free air generator with degreasing and water purification equipment, 3L / min Gas production 300ml / min, purity 99.999% Contains 99.999% high-purity nitrogen and pressure reducing valves (preferably purchased locally) Ethylene oxide standard Workstatio n Dual-channel, anti-control workstation Capillary injection system Split / splitless, with diaphragm cleaning function QBT 2929, GB/T10004-2008, YBB 00132002, GB 19083-2010, YY0469-2011, GB 2626-2006, YY/T0969-2013, YY/T0681.13-2014, GB/T32610-2016 9802-K Ethylene oxide gas chromatography comes with reasonable structure, stable and reliable performance, simple operation and easy maintenance. It can be widely used in the production and scientific research departments such as petroleum, chemical industry, pesticide, medicine and hygiene, commodity inspection, environment protection, college and so on. It is to detect organic solvents, the solvent residue of printed packaging materials and the purity or content of a single solvent. Economical and practical, excellent performance and quality. Adjustable gas circuit pressure, stable flow, with multiple gas circuit system of nitrogen, hydrogen, air, exhaust, shunt , cleaning. LCD screen displays temperature in real time. Cellular overall structure design, convenient to install and maintenance. Advanced noise resistant system, work quietly. Over-temperature protection function, with program protection and circuit protection double insurance. With data workstation, professional software support and powerful data analysis function. Display working condition and chromatogram curves; curves can be zoomed and moved. Professional test report, can export PDF file. Manual button switch, its function is equal to “start collecting”, which is convenient for sampling. Easy to operate detector and baseline calibration. Address: NO.1 Minghua 3 Street, Jinxiu Road, Economic Development Zone, Guangzhou, China https://www.gbpitester.com E-mail: [email protected]

 Open the catalog to page 1

All Guangzhou Biaoji Packaging Equipment Co., Ltd. catalogs and technical brochures

  1. GB-QL-720A

    7  Pages

  2. GBN702

    1  Page

  3. GBN701

    1  Page

  4. GB-BF20010

    1  Page

  5. GB-XF1000

    1  Page

  6. GB-PF400H

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.