1. Catalogs
  2. Guangzhou Baolun Electronic Company
  3. Zones Voice Evacuation Controller VA-2240WM
video corpo

Zones Voice Evacuation Controller VA-2240WM

Zones Voice Evacuation Controller VA-2240WM

Product catalog summary
Description:
The VA-2240WM is a 2-zone voice evacuation controller featuring a built-in 240W high-efficiency digital power amplifier. It offers dual-speaker loop zone outputs with independent LED indicators, output control buttons, and volume adjustments for each zone. The system includes 4 audio balanced input interfaces for zone-specific audio playback and supports local emergency PTT microphone input. Emergency voice configurations can be managed via PC software.

The controller automatically detects the working status of each zone loop and includes a 4-channel trigger input/output port for emergency voice activation. It supports third-party emergency audio input and integrates an independent EVAC/ALERT voice information player. Remote paging and fireman microphones can be connected using standard RJ-45 network ports and CAT-5 cables, ensuring long-distance balanced voice transmission.

The system supports DC24V battery backup, power amplifier monitoring, and PTT recording without external equipment. It includes system fault detection with dry contact outputs for emergency status and inputs for reset. Zone outputs feature three-wire and four-wire overriding adjustments, IP address reset, and impedance calibration functions. The master-slave unit configuration allows for up to 19 slaves online, supporting a maximum of 40 zones.

Specifications:
  • Model: VA-2240WM
  • Voltage: ~ 220V±20%, 50/60Hz
  • Fuse specifications: 2A slow breaking type
  • Balanced line input: Sensitivity ±385mV, Frequency response 80Hz~16KHz, Input impedance 10KΩ, Signal to noise ratio >70dB
  • RS485 interface: Supports up to 19 expansion machines with a baud rate of 38400bps
  • CAN interface: Baud rate 50Kbps, supports up to 28 remote microphones and 4 fireman remote microphones
  • Trigger mode: Short circuit trigger and level trigger
  • Output mode: Relay short circuit output
  • Size (L×W×H): 570×440×186mm
  • Net weight: 17.6Kg
  • Installation: Wall Mounted
  • Color: Fireman's Red
  • Operating temperature: +5℃~ +40℃
  • Storage temperature: -20℃~ +70℃
  • Relative temperature: <95%
  • MIC input: Sensitivity ±2.5mV, Frequency response 200Hz~10KHz, Input impedance 1KΩ, Signal to noise ratio >65dB
See more

Catalog excerpts

Zones Voice Evacuation Controller VA-2240WM-1

2 Zones Voice Evacuation Controller VA-2240WM n '1 '■ -v:' j.1 6 * Built-in 240W high-efficiency digital power amplifier, integrated 2 power A + B independent dual-speaker loop zone output, each zone has independent LED indicator, independent output control buttons and volume adjustment. * 4 audio balanced input interfaces for playing any audio source in the zones * Local emergency PTT microphone input and emergency voice can be configured by PC software to be played in specific zone. * Automatically detect the working status of each zone loop (fault, normal) * The 4-channel trigger input/output port can trigger the emergency voice preset by the PC software to the specified zone or the corresponding external power source to the corresponding event warning. * Support third-party emergency audio input (user-defined emergency audio source) * Integrated independent EVAC/ALERT voice information player. * The remote paging microphone / fireman microphone online interface can connect with remote paging microphone and fireman microphone, each paging station connection uses standard RJ-45 network port and standard CAT-5 network cable, voice transmission uses balanced transmission mode for long-distance transmission. * Controller online interface can be connected to the slave unit, it uses standard RJ-45 network port and standard CAT-5 network cable. * communication interface, supports visual interface operation based on Window platform, and the system status can be automatically synchronized. * Support DC24V battery backup power supply. * With power amplifier monitoring function. * Support PTT recording function, no external equipment required. * System fault, dry contact output for emergency status, dry contact input for emergency status reset * The zone output has three-wire and four-wire over-ridding adjustment functions. * With IP address reset function and impedance calibration function. * The master-slave unit is integrated, and the device can be used as a controller or a slave unit by setting code address, and the maximum of 19 slaves can be simultaneously online. * The system can extend the number of the zones by slave units, it support 40 zones maximum. Model Voltage Fuse specifications Specifications VA-2240WM ~ 220V±20%, 50/60Hz 2A slow breaking type Signal to noise ratio >65dB Balanced line input Sensitivity Frequency response Input impedance Signal to noise ratio RS485 interface Trigger mode Output mode Size (LxWxH) Net weight Installation Color Operating temperature Storage temperature Relative temperature ±385mV 80Hz~16KHz 10KQ >70dB Slave RS485 interface Supports the highest baud rate of 38400bps Support up to 19 expansion machines Remote MIC console CAN interface Baud rate 50Kbps Supports up to 28 remote Microphone and 4 Fireman Remote Microphone short circuit trigger and level trigger relay short circuit output 570x440x186mm 17.6Kg Wall Mounted Fireman’s Red +5°C~ +40°C -20oC~ +70C <95% www.itctech.com.cn [email protected]

 Open the catalog to page 1

All Guangzhou Baolun Electronic Company catalogs and technical brochures

  1. D-200

    1  Page

  2. TS-108HT

    1  Page

  3. LA-1180

    1  Page

  4. TS-9104UHM

    1  Page

  5. TR-0722

    1  Page

  6. TR-0703

    1  Page

  7. TR-0740S

    1  Page

  8. TR-0730

    1  Page

  9. TR-0726

    1  Page

  10. TR-0725

    1  Page

  11. TR-0723

    1  Page

  12. VA-6502 HE1

    1  Page

  13. VA-6502 HC1

    1  Page

  14. VA-6000MA

    2  Pages

  15. VA-6501 PP1

    1  Page

  16. VA-6500 CM1

    1  Page

  17. VA-8650WM

    2  Pages

  18. T-7700I7

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.