Catalog excerpts
Typical Features ♦Wide Input Voltage Range ( 2:1), Output Power 3W ♦ Conversion Efficiency up to 82% ♦With remote control Switch-off function ♦ Continuous Short Circuit protection, Self-fu rbish ♦ No Overshooting when turn-on or off ♦ Isolation Voltage 1500VDC ♦ Operating Temperature: -40°C~+85°C ♦ Plastic Case, meet UL94-V0 standard ® Case Material (6) Packing Code (5) Output Voltage @ Output Ways ® Input Voltage @ Output Power (T) Product Series Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25C. Stand-by Consumption Capacitor Filtering Input Filter Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A1 Date:2017-06-03 Page 1 of 8
Open the catalog to page 1Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A1 Date:2017-06-03 Page 2 of 8
Open the catalog to page 2Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A1 Date:2017-06-03 Page 3
Open the catalog to page 3Note: 1.“ ” are models under developing. 2. To ensure this module operate efficiently and reliably, the minimum output load could not be less than 10% of the nominal load during operation. If the actual output power is too small, please connect a resistor in parallel at the output, the resistance recommended equal to 10% nominal power. Characteristic Curve Input Voltage VS Efficiency(full load) 输入电压VS效率曲线图(满载) 输出负载VS效率曲线图 Output Load VS Efficiency(nominal voltage) Input Voltage & Stand by Consumption 输入电压与待机功耗曲线图 Output Load(%) Input Voltage & Stand by Consumption 输入电压与待机功耗曲线图...
Open the catalog to page 4Input Voltage VS Efficiency(full load) 输入电压VS效率曲线图(满载) 输出负载VS效率曲线图 Output Load VS Efficiency(nominal voltage) (标称电压) 输入电压与待机功耗曲线图 Input Voltage & Stand by Consumption 90 Input Voltage(Vdc) Input Voltage(Vdc) Output Load(%) Note: Photo 1,2,3 are 5V input series ; Photo 4,5,6 are 12V input series ; Photo 7,8,9 are 24V input series; Photo 10,11,12 are 48V input series. Temperature Curve 产品壳温与输出负载曲线图 Case Temperature & Output Load 温度降额曲线图 Temperature Derating Curve 输出功率百分比 Output Power Output Power Percent(%) Case Temperature(℃) Output Load(%) 输出负载(%) Packing Dimension, Pin Function,...
Open the catalog to page 5Note: if the definition of pin is not in accordance with the manual, please refer to the label on actual item. 1.CS terminal This terminal provides a connection point to connect the inside main filter capacitor of output terminal for the DC/DC converter(capacitor positive) , and can further improve the output ripple and noise (Normal CS<47uF) through connecting a low ESR capacitor between this terminal and the 7 pin (capacitor negative). 2.Output Load Request a. To ensure this module operate efficiently and reliably, the minimum load could not be less than 10% of the nominal load. If...
Open the catalog to page 63.Recommend Circuit DC/DC test circuit: If you want to further decrease input& output ripple, the capacitance of external capacitor can be increased properly, but the maximum capacitance of the filter capacitor should be less than the maximum capacitive load, otherwise it will make it difficult to turn-on the module. Normal Recommend: Ci:100uF (5V&12V) / 10uF (24V&48V) Li:4.7uH~120uH CS:10uF~22uF Co:100uF (Typ.) Lo;2.2uH~10uH C1:47nF/100V Single Output Positive Negative Dual Output Photo 13 4.CTRL Terminal Suspended or high resistance, output of module runs normally; Connect to high...
Open the catalog to page 76.Ripple& Noise Test: (Twisted Pair Method Test Method: a.12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, polypropylene capacitor and 47uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as Sample pattern. b. Input terminal connect to power supply, output terminal connect to electronic load through jig plate, Use 30cm± cm sampling line, 2 Power line selected from corresponding diameter wire with insulation according to the flow of output current. Note: 1.This product cannot be used in parallel, and do not support hot-plugging; 2. All...
Open the catalog to page 8All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures
-
WD50-XXSXXK1 Series
4 Pages
-
WD30/40 Series
3 Pages
-
WD30-XXXXXD1 Series
6 Pages
-
WD25-30D1 Series
3 Pages
-
RSH485-XXH Series
4 Pages
-
WR30-XXS75 WR40-XXS75 Series
3 Pages
-
BK25-600DXXH1 Series
6 Pages
-
BK20-600SXXH1 Series
5 Pages
-
BK20-600DXXH1 Series
6 Pages
-
BK15-600SXXH1 Series
5 Pages
-
BK15-600DXXH1 Series
5 Pages
-
WD75-XXSXXM1 series
4 Pages
-
FD50-XXSXXB3(C) Series
9 Pages
-
FD50-110SXXB3(C) Series
9 Pages
-
FD40-XXSXXB3C3 Series
9 Pages
-
FD30-XXSXXB3(C) Series
9 Pages
-
FD30-XXSXXA3(C) Series
9 Pages
-
FD30-110SXXB3C3 Series
9 Pages
-
FD25-XXSXXB3(C) Series
8 Pages
-
WD20-XXXXXC1 Series
6 Pages
-
UD6-XXXXXE3 Series
6 Pages
-
UD3-XXXXXE23/E3 Series
6 Pages
-
FD6-XXSXXA3 Series
8 Pages
-
FD6-XXDXXA3 Series
7 Pages
-
FD6-110SXXA3(C) Series
6 Pages
-
FD20-XXSXXA3(C) Series
8 Pages
-
FD20-XXDXXA3(C) Series
8 Pages
-
FD15-XXSXXA3(C) Series
7 Pages
-
FD15-XXDXXA3(C) Series
10 Pages
-
FD12-XXSXXA3(C) Series
8 Pages
-
FD12-XXDXXA3(C) Series
8 Pages
-
FD12-110SXXA3(C) Series
6 Pages
-
FD10-XXSXXA3(C) Series
7 Pages
-
FD10-XXDXXA3(C) Series
8 Pages
-
NW2-XXSXXC3 Series
3 Pages
-
NW1-XXSXXB3 Series
4 Pages
-
NN2-XXXXXH6 Series
5 Pages
-
KW3-XXXXXEA Series
5 Pages
-
KW3-XXXXXE3 Series
8 Pages
-
KW2-XXXXXEA Series
6 Pages
-
KW2-XXXXXE3 Series
8 Pages
-
KW1-XXXXXE3 Series
8 Pages
-
WA54-220D18K1 Series
6 Pages
-
WA50/60-220XXXK1B Series
4 Pages
-
FA40-220SXXH3 Series
6 Pages
-
UA15-220H05XXXXF2 Series
6 Pages
-
UA12-220SXXD3A Series
5 Pages
-
UA10-220SXXP2 Series
6 Pages
-
U10-220SXXP2D Series
5 Pages
-
FA8-220SXXD2 Series
6 Pages
-
FA6-220SXXD3 Series
6 Pages
-
FA6-220SXXD2 Series
5 Pages
-
FA30-220SXXH2 Series
6 Pages
-
FA25-220SXXH2 Series
7 Pages
-
FA25-220E05XXH2 Series
6 Pages
-
FA20-220H05XXXXH2 Series
6 Pages
-
FA15-380S05H24 Series
6 Pages
-
FA15-220SXXY2 Series
6 Pages
-
FA15-220SXXF2 Series
7 Pages
-
CK6-380SXXE2 Series
5 Pages
-
WA3-220SXXA3 Series
5 Pages
-
FA5-220SXXY2 Series
6 Pages
-
FA5-220SXXC2 Series
6 Pages
-
FA5-220EXXXXC2 Series
6 Pages
-
FA3-220SXXA2A series
6 Pages
-
FA2-220SXXA2A Series
6 Pages
-
FA1-220SXXN2 Series
5 Pages
-
FA5-220SXXB-1 Series
7 Pages
-
FA3-220SXXB-1 series
7 Pages
-
UA2-220SXXB series
7 Pages
-
NA200-220SXXM1 Series
3 Pages
-
UA10-220XXXP2 Series
5 Pages
-
UA15-XXXXXF2 Series
5 Pages
-
UA20-220HXXXXXXH2 Series
6 Pages
-
UA15/20-220HXXXXXXF2 Series
5 Pages
-
UA20-220XXXF2/F3 Series
6 Pages
-
UA25-220XXXH2 Series
6 Pages
-
NN2-XXXXXC3N Series
5 Pages
-
NN1-XXSXXANT Series
5 Pages
-
NN1-XXSXXH6 Series
5 Pages
-
NN1-XXXXXBN Series
5 Pages
-
NN1-XXXXXB3N Series
5 Pages
-
NN1-XXSXXAN Series
5 Pages
-
K78XX-500 Series
4 Pages
-
BB40-BB100 Series
4 Pages
-
BA150-BA200 Series
4 Pages
-
AC25-380S12H2 Series
6 Pages
-
FA10-220SXXE2 Series
6 Pages
-
FA20-220HXXXXXXH2 Series
6 Pages
-
FA3-220SXXA2A
6 Pages
-
FA3-220SXXB Series
7 Pages
-
K78XX-1000 Series
4 Pages
-
WA6-220SXXD3 Series
5 Pages
-
WA40/50-220XXXK1 Series
5 Pages
-
FA5-220SXXB Series
7 Pages
-
AC25-H2 Series
6 Pages