KW2-XXXXXEA Series
6Pages

{{requestButtons}}

Catalog excerpts

KW2-XXXXXEA Series - 1

KW2-XXXXXEA Series DC-DC Converter Typical Features ♦ Wide Input Voltage Range (4:1), Output Power 2W ♦ Transfer Efficiency up to 82% ♦ With remote control Switch-off function ♦ Continuous Short Circuit protection, Self-recovery ♦ No Overshooting when turn-on or off ♦ Isolation Voltage 1500VDC ♦ Operating Temperature: -40°C^+85°C ♦ Plastic Case, meet UL94 V-0 standard ® Suffix (7) Isolation Voltage (6) Packing Code (5) Output Voltage (D Output Method (3) Input Voltage (2) Output Power (T) Product Series Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25°C. Stand-by Power Consumption Capacitor Filter Input Filter Positive Output Voltage Accuracy Full voltage full load Guangzhou Aipu Electron Technology Co., Ltd CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 Hotline: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2016-9-10 Page1of6

Open the catalog to page 1
KW2-XXXXXEA Series - 2

Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 Hotline: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2016-9-10 Page2of6

Open the catalog to page 2
KW2-XXXXXEA Series - 3

Note: 1.“*” are models under developing. 2.To ensure this module operate efficiently and reliably, the minimum load could not be less than 10% of the nominal load. If the actual power is too small, please connect a resistor in parallel at output terminal, the resistance equal to 10% nominal load. Characteristic Curve Temperature Derating Curve 温度降额曲线图 100% 90% 输出功率百分比 Output Power Packing Dimension, Pin Function, Recommended PCB layout Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel:...

Open the catalog to page 3
KW2-XXXXXEA Series - 4

Packing Dimension * Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Packing Dimension Packing Code E Design and Application Circuit Recommended 1.CS terminal This terminal provides a connection point to connect the inside main filter capacitor of output terminal for the DC/DC converter(capacitor positive) , and can further improve the output ripple and noise (Normal CS≤47uF) through connecting a low ESR capacitor between this terminal and the 7 pin (capacitor negative). 2.Output Load Request a. To ensure this...

Open the catalog to page 4
KW2-XXXXXEA Series - 5

DC/DC test circuit: If you want to further decrease input& output ripple, the capacitance of external capacitor can be increased properly, but the maximum capacitance of the filter capacitor should be less than the maximum capacitive load, otherwise it will make it difficult to turn-on the module. Normal Recommended: Ci:100uF (18V) / 10uF (36V) Li:4.7uH~120uH CS:10uF~22uF Co:100uF (Typ.) Lo:2.2uH~10uH C1:47nF/100V Li Single Output Positive Negative Dual Output Photo 13 4.CTRL Terminal Suspended or high resistance, output of module runs normally; Connect to high level(relative to input...

Open the catalog to page 5
KW2-XXXXXEA Series - 6

6.Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: a.12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, 100M bandwidth probe, terminated with 0.1uF polypropylene capacitor and 47uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as Sample pattern. b. Input terminal connect to power supply, output terminal connect to electronic load through jig plate, Use 30cm±2 cm sampling line, Power line selected from corresponding diameter wire with insulation according to the flow of output current. * Note: 1 .This product cannot be...

Open the catalog to page 6