Catalog excerpts
AIPULNION DC/DC ConverterFD6-XXDXXA3(-T)(-TS) Series Product Typical Features ♦ Wide input voltage range( 4:1), Output Power 6W ♦ Transfer Efficiency up to 84% ♦ Short Circuit protection, Self-recovery ♦ Protection: input under-voltage, over-voltage, short circuit, over current ♦ Switching Frequency 250KHz ♦ Isolation Voltage: 1500VDC ♦ Operating Temperature: -40°C~+85°C ♦ Good EMI performance ♦ International standard pin-out Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25C. Application Field FD6-XXDXXA3 is a newly designed DIP 1X1 packed, 6Woutput power, ultra wide input range 4:1, low stand-by power consumption, isolated regulated dual but common ground output DC-DC converter, could be widely used for industrial control, instrument, communication, power electricity, internet of things field. Typical Product List Guangzhou Aipu Electron Technology Co., Ltd Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Gang, Shiliu Gang, Haizhu Dis, GZ,CN Website: http://www.aipulnion.com/ Date: 2019-5
Open the catalog to page 1AIPULNION DC/DC ConverterFD6-XXDXXA3(-T)(-TS) Series C€ RoHS 1. “*” are models being developing; 2. ”-T” suffix for chassis mounting, ”-TS” suffix for DIN-Rail mounting, DIN-Rail width is: 35mm; 3. Max capacitive load is, when the power supply is fully loaded, the max capacity could be connected to output, if exceed, the power supply cannot start-up; Input Specification Stand-by Consumption Input Filter Input under-voltage protection Output Specification Main Circuit Output Voltage Accuracy Output Over-voltage protection Output Over-load Protection Output Short circuit Protection Continuous...
Open the catalog to page 2AIPULNION DC/DC ConverterFD6-XXDXXA3(-T)(-TS) Series C€ RoHS Meantime Between Failure Product Weight Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-5-29 Page3of7
Open the catalog to page 3AIPULNION DC/DC ConverterFD6-XXDXXA3(-T)(-TS) Series Package Dimension Unit: mm Print board vertical view Grid: 2.54mm(0.1inch) General tolerance: ±0.25mm Pin section tolerances: ±0.10mm A3 Packing Dimension LxWxH Packing Code Pin out Specifications Dual Output(D) Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE:...
Open the catalog to page 4DC/DC Converter FD6-XXDXXA3(-T)(-TS) Series Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: a. 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, 100M bandwidth probe, terminated with 0.1uF polypropylene capacitor and 10uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as Sample pattern. b. Input terminal connect to power supply, output terminal connect to electronic load through jig plate, Use 30cm±2 cm sampling line, Power line selected from corresponding diameter wire with insulation according to the flow of output...
Open the catalog to page 5DC/DC Converter FD6-XXDXXA3(-T)(-TS) Series Design Application Recommended circuit 1. DC/DC test circuit: Normal recommended capacitors: C0:47-100uF;C1: 470uF. 2. Input reflecting ripple current test circuit: Capacitor C choose low ESR ones, withstand voltage value should be bigger than max input voltage; 3.EMC external recommended circuit: Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/...
Open the catalog to page 6AIPULNION DC/DC ConverterFD6-XXDXXA3(-T)(-TS) Series Recommended Spec: 1. The product should be used under the specification range, otherwise it will cause permanent damage to it. 2. If the product worked beyond the load range or below the minimum load, we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 3. Unless otherwise specified, data in this datasheet should be tested under conditions of Ta=25°C, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load); 4. All index testing methods in this datasheet...
Open the catalog to page 7All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures
-
WD50-XXSXXK1 Series
4 Pages
-
WD30/40 Series
3 Pages
-
WD30-XXXXXD1 Series
6 Pages
-
WD25-30D1 Series
3 Pages
-
RSH485-XXH Series
4 Pages
-
WR30-XXS75 WR40-XXS75 Series
3 Pages
-
BK25-600DXXH1 Series
6 Pages
-
BK20-600SXXH1 Series
5 Pages
-
BK20-600DXXH1 Series
6 Pages
-
BK15-600SXXH1 Series
5 Pages
-
BK15-600DXXH1 Series
5 Pages
-
WD75-XXSXXM1 series
4 Pages
-
FD50-XXSXXB3(C) Series
9 Pages
-
FD50-110SXXB3(C) Series
9 Pages
-
FD40-XXSXXB3C3 Series
9 Pages
-
FD30-XXSXXB3(C) Series
9 Pages
-
FD30-XXSXXA3(C) Series
9 Pages
-
FD30-110SXXB3C3 Series
9 Pages
-
FD25-XXSXXB3(C) Series
8 Pages
-
WD20-XXXXXC1 Series
6 Pages
-
UD6-XXXXXE3 Series
6 Pages
-
UD3-XXXXXE23/E3 Series
6 Pages
-
FD6-XXSXXA3 Series
8 Pages
-
FD6-110SXXA3(C) Series
6 Pages
-
FD20-XXSXXA3(C) Series
8 Pages
-
FD20-XXDXXA3(C) Series
8 Pages
-
FD15-XXSXXA3(C) Series
7 Pages
-
FD15-XXDXXA3(C) Series
10 Pages
-
FD12-XXSXXA3(C) Series
8 Pages
-
FD12-XXDXXA3(C) Series
8 Pages
-
FD12-110SXXA3(C) Series
6 Pages
-
FD10-XXSXXA3(C) Series
7 Pages
-
FD10-XXDXXA3(C) Series
8 Pages
-
NW2-XXSXXC3 Series
3 Pages
-
NW1-XXSXXB3 Series
4 Pages
-
NN2-XXXXXH6 Series
5 Pages
-
KW3-XXXXXEA Series
5 Pages
-
KW3-XXXXXE3 Series
8 Pages
-
KW2-XXXXXEA Series
6 Pages
-
KW2-XXXXXE3 Series
8 Pages
-
KW1-XXXXXE3 Series
8 Pages
-
WA54-220D18K1 Series
6 Pages
-
WA50/60-220XXXK1B Series
4 Pages
-
FA40-220SXXH3 Series
6 Pages
-
UA15-220H05XXXXF2 Series
6 Pages
-
UA12-220SXXD3A Series
5 Pages
-
UA10-220SXXP2 Series
6 Pages
-
U10-220SXXP2D Series
5 Pages
-
FA8-220SXXD2 Series
6 Pages
-
FA6-220SXXD3 Series
6 Pages
-
FA6-220SXXD2 Series
5 Pages
-
FA30-220SXXH2 Series
6 Pages
-
FA25-220SXXH2 Series
7 Pages
-
FA25-220E05XXH2 Series
6 Pages
-
FA20-220H05XXXXH2 Series
6 Pages
-
FA15-380S05H24 Series
6 Pages
-
FA15-220SXXY2 Series
6 Pages
-
FA15-220SXXF2 Series
7 Pages
-
CK6-380SXXE2 Series
5 Pages
-
WA3-220SXXA3 Series
5 Pages
-
FA5-220SXXY2 Series
6 Pages
-
FA5-220SXXC2 Series
6 Pages
-
FA5-220EXXXXC2 Series
6 Pages
-
FA3-220SXXA2A series
6 Pages
-
FA2-220SXXA2A Series
6 Pages
-
FA1-220SXXN2 Series
5 Pages
-
FA5-220SXXB-1 Series
7 Pages
-
FA3-220SXXB-1 series
7 Pages
-
UA2-220SXXB series
7 Pages
-
NA200-220SXXM1 Series
3 Pages
-
UA10-220XXXP2 Series
5 Pages
-
UA15-XXXXXF2 Series
5 Pages
-
UA20-220HXXXXXXH2 Series
6 Pages
-
UA15/20-220HXXXXXXF2 Series
5 Pages
-
UA20-220XXXF2/F3 Series
6 Pages
-
UA25-220XXXH2 Series
6 Pages
-
NN2-XXXXXC3N Series
5 Pages
-
NN1-XXSXXANT Series
5 Pages
-
NN1-XXSXXH6 Series
5 Pages
-
NN1-XXXXXBN Series
5 Pages
-
NN1-XXXXXB3N Series
5 Pages
-
NN1-XXSXXAN Series
5 Pages
-
KW3-XXXXXE Series
8 Pages
-
K78XX-500 Series
4 Pages
-
BB40-BB100 Series
4 Pages
-
BA150-BA200 Series
4 Pages
-
AC25-380S12H2 Series
6 Pages
-
FA10-220SXXE2 Series
6 Pages
-
FA20-220HXXXXXXH2 Series
6 Pages
-
FA3-220SXXA2A
6 Pages
-
FA3-220SXXB Series
7 Pages
-
K78XX-1000 Series
4 Pages
-
WA6-220SXXD3 Series
5 Pages
-
WA40/50-220XXXK1 Series
5 Pages
-
FA5-220SXXB Series
7 Pages
-
AC25-H2 Series
6 Pages