FD15-XXDXXA3(C) Series
10Pages

{{requestButtons}}

Catalog excerpts

FD15-XXDXXA3(C) Series - 1

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series Product Typical Features Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25°C. Application Field FD15-XXDXXA3(C) is a newly designed DIP 1X1 packed, 15W output power, ultra wide input range 4:1, low stand-by power consumption, isolated regulated output DC-DC converter, could be widely used for industrial control, instrument, communication, power electricity, internet of things field. Typical Product List Part No Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-06-

Open the catalog to page 1
FD15-XXDXXA3(C) Series - 2

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series .FD15-36D05A3(C) Stand-by Consumption Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-06-24 Page2of10

Open the catalog to page 2
FD15-XXDXXA3(C) Series - 3

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series a rohs Output Over-load Protection Output Short circuit Protection Continuous, Self-recovery Dynamic Response 25% nominal load step change AVo/At Other Output Output Voltage Adjustment Turn-on delay time Output Turn-on Overshoot Voltage Note: * Ripple&Noise should be tested under the Parallel Line Test Method. Switching Frequency Operating Temperature Refer to Temperature Derating Curve Storage Temperature Within Operating Curve Relative Humidity Case Material Aluminum Metal Case Cooling Method Isolation Voltage Meantime Between...

Open the catalog to page 3
FD15-XXDXXA3(C) Series - 4

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series A3 Packing Dimension(without heat sink) Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. A3-H Packing Dimension(with heat sink) Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final...

Open the catalog to page 4
FD15-XXDXXA3(C) Series - 5

DC/DC Converter A3-TH Package Dimension(with heat sink) A3-TS Package Dimension(without heat sink) Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2019-06-24 Page 5 of 1

Open the catalog to page 5
FD15-XXDXXA3(C) Series - 6

DC/DC Converter A3-TSH Package Dimension(with heat sink) Packing Code Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2019-06-24 Page 6 of 1

Open the catalog to page 6
FD15-XXDXXA3(C) Series - 7

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series A3-TS(without heat sink) Test Method: Note: C1=1uF;C2=10uF; the withstand value of the capacitor should be bigger the output voltage of the module. Application Reference: 1.The recommended minimum load is 15% or above 470uF high frequency low resistance electrolytic capacitor, or output ripple will rise; 2.Recommend the unbalance loads of dual output to be <±5%; 3.The maximum capacitive load is tested under pure resistance and full load condition; 4.Our company could provide whole power supply solution, or customized made items; Due...

Open the catalog to page 7
FD15-XXDXXA3(C) Series - 8

DC/DC Converter Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version:A/0 Date:2019-06-24 Page 8 of 1

Open the catalog to page 8
FD15-XXDXXA3(C) Series - 9

DC/DC Converter FD15-XXDXXA3(C)(-T)(-TS) Series Design Application Recommended circuit 1. DC/DC test circuit: Normal recommended capacitors: 2. Input reflecting ripple current test circuit: Capacitor C choose low ESR ones, withstand voltage value should be bigger than max input voltage; 3. EMC external recommended circuit: Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron...

Open the catalog to page 9
FD15-XXDXXA3(C) Series - 10

AIPULNION DC/DC ConverterFD15-XXDXXA3(C)(-T)(-TS) Series Recommended Spec: 1. The product should be used under the specification range, otherwise it will cause permanent damage to it. 2. If the product worked beyond the load range or below the minimum load, we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 3. Unless otherwise specified, data in this datasheet should be tested under conditions of Ta=25°C, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load); 4. All index testing methods in this...

Open the catalog to page 10