FD12-110SXXA3(C) Series
6Pages

{{requestButtons}}

Catalog excerpts

FD12-110SXXA3(C) Series - 1

AIPULNION DC/DC Converter FD12-110SXXA3(C) Series C€ RoHS Typical Features Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25°C. Application Field FD12-110SXXA3(C) is a newly designed DIP 1X1 packed, 12W output power, ultra wide input range 4:1, low stand-by power consumption, isolated regulated output DC-DC converter, could be widely used for industrial control, instrument, communication, power electricity, internet of things field. Typical Product List Part No 1. “*” are models being developing; 2. Max capacitive load is, when the power supply is fully loaded, the max capacity could be connected to output, if exceed, the power supply cannot start-up; Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/1 Date: 2019-1-10 Pag

Open the catalog to page 1
FD12-110SXXA3(C) Series - 2

AIPULNION DC/DC Converter FD12-110SXXA3(C) Series 3. To reduce no load power consumption and improve efficiency of light-load, IC will be flitter frequency under no-load and light-load operating, output cannot be no load, at least with 10% load or above 470uF high frequency low resistance electrolytic capacitor, otherwise the output ripple will rise; 4. Suffix ”C” is with Control function. Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE:...

Open the catalog to page 2
FD12-110SXXA3(C) Series - 3

AIPULNION DC/DC Converter FD12-110SXXA3(C) Series C€ RoHS Relative Humidity Case Material Aluminum Metal Case Cooling Method Isolation Voltage Meantime Between Failure Product Weight Packing Code Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu Electron...

Open the catalog to page 3
FD12-110SXXA3(C) Series - 4

DC/DC Converter FD12-110SXXA3(C) Series Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: a. 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, polypropylene capacitor and 10uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as Sample pattern. b. Input terminal connect to power supply, output terminal connect to electronic load through jig plate, Use 30cm±2 cm sampling line, Power line selected from corresponding diameter wire with insulation according to the flow of output current. Application Reference: 1.The...

Open the catalog to page 4
FD12-110SXXA3(C) Series - 5

DC/DC Converter FD12-110SXXA3(C) Series Design Application Recommended circuit DC/DC test circuit: Normal recommended capacitors: C0:47-100uF;C1;470uF. 2. Input reflecting ripple current test circuit: Capacitor C choose low ESR ones, withstand voltage value should be bigger than max input voltage; 3.EMC external recommended circuit: Guangzhou Aipu Electron Technology Co., Ltd Add: Building B, No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 HOTLINE: 400-811-8032 Website: http://www.aipulnion.com/ Guangzhou Aipu...

Open the catalog to page 5
FD12-110SXXA3(C) Series - 6

DC/DC Converter FD12-110SXXA3(C) Series C€ RoHS Recommended Spec: Component 1. The product should be used under the specification range, otherwise it will cause permanent damage to it. 2. If the product worked beyond the load range or below the minimum load, we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 3. Unless otherwise specified, data in this datasheet should be tested under conditions of Ta=25°C, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load); 4. All index testing methods in this...

Open the catalog to page 6

All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures