FA40-220SXXH3 Series
6Pages

{{requestButtons}}

Catalog excerpts

FA40-220SXXH3 Series - 1

AIPULNION AC/DC Converter FA40-220SXXH3 Series Typical Features ♦Wide input voltage range 85~265VAC/120-380VDC ♦ No load power consumption<0.3W ♦Transfer Efficiency 85%(Typical) ♦ Switching Frequency: 65KHz ♦ Protections: over current, short circuit, over voltage, over temperature ♦ Isolation Voltage: 3750Vac ♦ Metal Case H3 ♦ PCB Mounting FA40-220SXXH3 Series-----a compact size, high efficient, power converter offered by Aipu. It features universal input voltage, taking both DC and AC input, low ripple, low temperature rise, low power consumption, high efficiency, high reliability, safer isolation, safe and reliable, with good EMC performance. EMC and Safety specification meet international EN55032, IEC/EN61000 standard. It is widely used in industrial, office and civil applications. Please refer to this datasheet when module being used in a bad EMC environment. Typical Product List Model Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/1 Date:2017-09-14 Page 1 of 6

Open the catalog to page 1
FA40-220SXXH3 Series - 2

AIPULNION AC/DC Converter FA40-220SXXH3 Series CC Rohs Technical Parameters: Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25°C. Input Specification Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of...

Open the catalog to page 2
FA40-220SXXH3 Series - 3

AC/DC Converter FA40-220SXXH3 Series Over-voltage Protection Note: Ripple& Noise is tested by Twisted Pair Method, details please see Ripple& Noise Test at back. General Specification Items Operating Conditions Switching Frequency Operating Temperature Storage Temperature Relative Humidity Isolation Voltage Insulation Resistance Class of Case Material Electromagnetic Compatibility(EMC) Characteristics Total Items Voltage dips, short interruptions and voltage variations immunity Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu...

Open the catalog to page 3
FA40-220SXXH3 Series - 4

AIPULNION AC/DC Converter FA40-220SXXH3 Series Unit: mm(inch); Grid:2.54mm(0.1inch); Printed board vertical view; General tolerances: ±0.25mm; General Pin Diameter tolerances: Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: (1) 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, 100M bandwidth probe, terminated with 0.1uF polypropylene capacitor and 47uF high frequency low resistance electrolytic capacitor in parallel,...

Open the catalog to page 4
FA40-220SXXH3 Series - 5

AIPULNION AC/DC Converter FA40-220SXXH3 Series CC Rohs Temperature Derating Curve Ambient temperature(°C ) Note 1: Input Voltage should be derated base on Input Voltage Derating Curve when it is 85~100VAC/ 277~305VAC / 120~140VDC/ 390~430VDC. 2: Our product is suitable to use under natural air cooling environment, if use it under closed condition, please contact with us. Typical Application and Recommend Circuitl Photo 1:Typical application circuit Part No Note: Output filter capacitor C2 is electrolytic capacitors, recommend to use high frequency and low resistance one, for capacitance and...

Open the catalog to page 5
FA40-220SXXH3 Series - 6

AIPULNION AC/DC Converter FA40-220SXXH3 Series CC Rohs I.The product should be used under the specification range, otherwise it will cause permanent damage to it. 2.Product's input terminal should connect to fuse; 3. If the product worked beyond the load range, we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 4.Unless otherwise specified, data in this datasheet are tested under conditions of Ta=25°C, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load); 5.All index testing methods in this datasheet...

Open the catalog to page 6