Catalog excerpts
AIPULNION AC/DC ConverterFA15-220SXXY2 Typical Features ♦ Wide input voltage range:85-265VAC/120-380VDC ♦ No-load power consumption<0.2W ♦ Transfer efficiency: 86%(typ.) ♦ Switching frequency: 65KHz(typ.) ♦ Protection: Short Circuit, Over Current, Over Voltage ♦ Isolation voltage: 3000VAC ♦ Safety Class: CLASS II Application Field FA15-220SXXY2—a compact size, high efficient power converter offered by Aipu. It features universal input voltage, DC and AC dual-use, low ripple, low temperature rise, low power consumption, high efficiency, high reliability, safer isolation. It widely used in industrial,office power and home applications. Typical Product List Certif icate Note 1: Due to space limitations, above is only a part of our product list, please contact our sales team for more items. Note 2: Due to the instrument deviation of the test equipment, the minimum efficiency is -2% of the typical value . Note 3: The typical output efficiency is based on that product is full loaded and burned-in after half an hour. Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-01-24 Page 1 of 6
Open the catalog to page 1AIPULNION AC/DC ConverterFA15-220SXXY2 RoHS Remote control terminal Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-01-24 Page 2 of 6
Open the catalog to page 2AIPULNION AC/DC ConverterFA15-220SXXY2 Storage Temperature Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2019-01-24 Page 3 of 6
Open the catalog to page 33^/S^"? AIPULNION AC/DC ConverterFA15-220SXXY2 Packing Dimension ‘t'- (Unit:) : mm E[1Mft®$!E(Printed board vertical view) t§Nit(latticspacing) :2. 54mm(0. 1 inch) (fctipftKTf'&iS+O. 25mm ik !t| tf W S fc&ie ± 0. 10mm Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: (1) 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, 100M bandwidth probe, terminated with 0.1 uF polypropylene capacitor and IOuF high frequency low resistance...
Open the catalog to page 4Product Characteristic Curve Note 1: Input Voltage should be derated base on Input Voltage Derating Curve when it is 85~100VAC/ 240~265VAC/ 120~140VDC/ 340~380VDC. 2: Our product is suitable to use under natural air cooling environment, if use it under closed condition, please contact with us. Application Design Referenced EMC Solution and Recommend Circuit Note: 1. FUSE: necessary, suggest 1A/300V, slow fusing; 2. NTC1 is thermistors, suggest model:5D-11, to prevent the module from damage when lightning surge. 3. MOV is piezoresistance,suggest model: 14D561K,to prevent the module from...
Open the catalog to page 5Note : 1.The product should be used under the specification range, otherwise it will cause permanent damage to it. 2.Product’s input terminal should connect to fuse; 3.If the product is not worked under the load range(below the minimum load or beyond the load range), we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 4.Unless otherwise specified, data in this datasheet are tested under conditions of Ta=25℃, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load); 5.All index testing methods in this...
Open the catalog to page 6All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures
-
WD50-XXSXXK1 Series
4 Pages
-
WD30/40 Series
3 Pages
-
WD30-XXXXXD1 Series
6 Pages
-
WD25-30D1 Series
3 Pages
-
RSH485-XXH Series
4 Pages
-
WR30-XXS75 WR40-XXS75 Series
3 Pages
-
BK25-600DXXH1 Series
6 Pages
-
BK20-600SXXH1 Series
5 Pages
-
BK20-600DXXH1 Series
6 Pages
-
BK15-600SXXH1 Series
5 Pages
-
BK15-600DXXH1 Series
5 Pages
-
WD75-XXSXXM1 series
4 Pages
-
FD50-XXSXXB3(C) Series
9 Pages
-
FD50-110SXXB3(C) Series
9 Pages
-
FD40-XXSXXB3C3 Series
9 Pages
-
FD30-XXSXXB3(C) Series
9 Pages
-
FD30-XXSXXA3(C) Series
9 Pages
-
FD30-110SXXB3C3 Series
9 Pages
-
FD25-XXSXXB3(C) Series
8 Pages
-
WD20-XXXXXC1 Series
6 Pages
-
UD6-XXXXXE3 Series
6 Pages
-
UD3-XXXXXE23/E3 Series
6 Pages
-
FD6-XXSXXA3 Series
8 Pages
-
FD6-XXDXXA3 Series
7 Pages
-
FD6-110SXXA3(C) Series
6 Pages
-
FD20-XXSXXA3(C) Series
8 Pages
-
FD20-XXDXXA3(C) Series
8 Pages
-
FD15-XXSXXA3(C) Series
7 Pages
-
FD15-XXDXXA3(C) Series
10 Pages
-
FD12-XXSXXA3(C) Series
8 Pages
-
FD12-XXDXXA3(C) Series
8 Pages
-
FD12-110SXXA3(C) Series
6 Pages
-
FD10-XXSXXA3(C) Series
7 Pages
-
FD10-XXDXXA3(C) Series
8 Pages
-
NW2-XXSXXC3 Series
3 Pages
-
NW1-XXSXXB3 Series
4 Pages
-
NN2-XXXXXH6 Series
5 Pages
-
KW3-XXXXXEA Series
5 Pages
-
KW3-XXXXXE3 Series
8 Pages
-
KW2-XXXXXEA Series
6 Pages
-
KW2-XXXXXE3 Series
8 Pages
-
KW1-XXXXXE3 Series
8 Pages
-
WA54-220D18K1 Series
6 Pages
-
WA50/60-220XXXK1B Series
4 Pages
-
FA40-220SXXH3 Series
6 Pages
-
UA15-220H05XXXXF2 Series
6 Pages
-
UA12-220SXXD3A Series
5 Pages
-
UA10-220SXXP2 Series
6 Pages
-
U10-220SXXP2D Series
5 Pages
-
FA8-220SXXD2 Series
6 Pages
-
FA6-220SXXD3 Series
6 Pages
-
FA6-220SXXD2 Series
5 Pages
-
FA30-220SXXH2 Series
6 Pages
-
FA25-220SXXH2 Series
7 Pages
-
FA25-220E05XXH2 Series
6 Pages
-
FA20-220H05XXXXH2 Series
6 Pages
-
FA15-380S05H24 Series
6 Pages
-
FA15-220SXXF2 Series
7 Pages
-
CK6-380SXXE2 Series
5 Pages
-
WA3-220SXXA3 Series
5 Pages
-
FA5-220SXXY2 Series
6 Pages
-
FA5-220SXXC2 Series
6 Pages
-
FA5-220EXXXXC2 Series
6 Pages
-
FA3-220SXXA2A series
6 Pages
-
FA2-220SXXA2A Series
6 Pages
-
FA1-220SXXN2 Series
5 Pages
-
FA5-220SXXB-1 Series
7 Pages
-
FA3-220SXXB-1 series
7 Pages
-
UA2-220SXXB series
7 Pages
-
NA200-220SXXM1 Series
3 Pages
-
UA10-220XXXP2 Series
5 Pages
-
UA15-XXXXXF2 Series
5 Pages
-
UA20-220HXXXXXXH2 Series
6 Pages
-
UA15/20-220HXXXXXXF2 Series
5 Pages
-
UA20-220XXXF2/F3 Series
6 Pages
-
UA25-220XXXH2 Series
6 Pages
-
NN2-XXXXXC3N Series
5 Pages
-
NN1-XXSXXANT Series
5 Pages
-
NN1-XXSXXH6 Series
5 Pages
-
NN1-XXXXXBN Series
5 Pages
-
NN1-XXXXXB3N Series
5 Pages
-
NN1-XXSXXAN Series
5 Pages
-
KW3-XXXXXE Series
8 Pages
-
K78XX-500 Series
4 Pages
-
BB40-BB100 Series
4 Pages
-
BA150-BA200 Series
4 Pages
-
AC25-380S12H2 Series
6 Pages
-
FA10-220SXXE2 Series
6 Pages
-
FA20-220HXXXXXXH2 Series
6 Pages
-
FA3-220SXXA2A
6 Pages
-
FA3-220SXXB Series
7 Pages
-
K78XX-1000 Series
4 Pages
-
WA6-220SXXD3 Series
5 Pages
-
WA40/50-220XXXK1 Series
5 Pages
-
FA5-220SXXB Series
7 Pages
-
AC25-H2 Series
6 Pages