♦ Wide input voltage range:85-265VAC/120-380VDC ♦ Transfer efficiency (typ. 87%) ♦ Switching frequency: 65KHz ♦ Protection: Short Circuit, Over Current, Over Voltage, Over Temperature ♦ Isolation voltage: 4000Vac ♦ Meet IEC60950/UL60950/EN60950 ♦ Confirm to CE. RoHS ♦ Plastic case, conform to UL94V-0 Class ♦ PCB mounting FA15-220SXXF2 Series— a compact size, high efficient, meet CE standard power converter offered by Aipu. It features universal input voltage, DC and AC dual-use, low ripple, low temperature rise, low power consumption, high efficiency, high reliability, safer isolation, with good EMC performance.EMC and Safety standard meet international EN55032,IEC/EN61000. It widely used in power, industrial, instrument, smart home applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended. Typical Product List Certif icate Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2018-04-18 Page 1 of 7
Open the catalog to page 1AIPULNION AC/DC ConverterFA15-220SXXF2 Series C€ RoHS Note 1: Due to space limitations, above is only a part of our product list, please contact our sales team for more items. Note 2:.”*” is model under developing. Note 3: The typical output efficiency is based on that product is full loaded and burned-in after half an hour. Note 4: The fluctuation range of full load efficiency(%,TYP) is ±2%, full load output efficiency= total output power/module's input power. Input Specification Item Output Specification Item Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard,...
Open the catalog to page 2AIPULNION AC/DC ConverterFA15-220SXXF2 Series Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date: 2018-04-18 Page 3 of 7
Open the catalog to page 3AIPULNION AC/DC ConverterFA15-220SXXF2 Series C€ RoHS EMC Characteristics Total Item Packing Code Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax:86-20-84206762 HOTLINE: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Version: A/0 Date:...
Open the catalog to page 4AC/DC Converter FA15-220SXXF2 Series Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: (1) 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, 100M bandwidth probe, terminated with 0.1uF polypropylene capacitor and 10uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as Sample pattern. (2) Input terminal connect to power supply, output terminal connect to electronic load through jig plate, Use 30cm±2 cm sampling line. Power line selected from corresponding diameter wire with insulation according to the flow of output...
Open the catalog to page 5AIPULNION AC/DC ConverterFA15-220SXXF2 Series C€ RoHS Typical EMC Circuit and Recommended Spec 1. Typical Application Circuit Output voltage Note: Output capacitor C1 is ceramic capacitor, to filter high frequency noise. TVS tube is a recommend component to protect post-circuit if converter fails. Recommend to external FUSE, Model:2A/250V, slow fusing. Recommend to external MOV voltage dependent resistor, model:14D511K. 2.EMC solution recommended circuit 15mH, recommended to use our common mode inductor Guangzhou Aipu Electron Technology Co., Ltd Add: B Building ,No.4 Courtyard, Qixing...
Open the catalog to page 6AC/DC Converter FA15-220SXXF2 Series Note : 1.The product should be used under the specification range, otherwise it will cause permanent damage to it. 2.Product’s input terminal should connect to fuse; 3.If the product is not worked under the load range(below the minimum load or beyond the load range), we cannot ensure that the performance of product is in accordance with all the indexes in this manual; 4.Unless otherwise specified, data in this datasheet are tested under conditions of Ta=25℃, humidity<75% when inputting nominal voltage and outputting rated load(pure resistance load);...
Open the catalog to page 7All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures
-
WD50-XXSXXK1 Series
4 Pages
-
WD30/40 Series
3 Pages
-
WD30-XXXXXD1 Series
6 Pages
-
WD25-30D1 Series
3 Pages
-
RSH485-XXH Series
4 Pages
-
WR30-XXS75 WR40-XXS75 Series
3 Pages
-
BK25-600DXXH1 Series
6 Pages
-
BK20-600SXXH1 Series
5 Pages
-
BK20-600DXXH1 Series
6 Pages
-
BK15-600SXXH1 Series
5 Pages
-
BK15-600DXXH1 Series
5 Pages
-
WD75-XXSXXM1 series
4 Pages
-
FD50-XXSXXB3(C) Series
9 Pages
-
FD50-110SXXB3(C) Series
9 Pages
-
FD40-XXSXXB3C3 Series
9 Pages
-
FD30-XXSXXB3(C) Series
9 Pages
-
FD30-XXSXXA3(C) Series
9 Pages
-
FD30-110SXXB3C3 Series
9 Pages
-
FD25-XXSXXB3(C) Series
8 Pages
-
WD20-XXXXXC1 Series
6 Pages
-
UD6-XXXXXE3 Series
6 Pages
-
UD3-XXXXXE23/E3 Series
6 Pages
-
FD6-XXSXXA3 Series
8 Pages
-
FD6-XXDXXA3 Series
7 Pages
-
FD6-110SXXA3(C) Series
6 Pages
-
FD20-XXSXXA3(C) Series
8 Pages
-
FD20-XXDXXA3(C) Series
8 Pages
-
FD15-XXSXXA3(C) Series
7 Pages
-
FD15-XXDXXA3(C) Series
10 Pages
-
FD12-XXSXXA3(C) Series
8 Pages
-
FD12-XXDXXA3(C) Series
8 Pages
-
FD12-110SXXA3(C) Series
6 Pages
-
FD10-XXSXXA3(C) Series
7 Pages
-
FD10-XXDXXA3(C) Series
8 Pages
-
NW2-XXSXXC3 Series
3 Pages
-
NW1-XXSXXB3 Series
4 Pages
-
NN2-XXXXXH6 Series
5 Pages
-
KW3-XXXXXEA Series
5 Pages
-
KW3-XXXXXE3 Series
8 Pages
-
KW2-XXXXXEA Series
6 Pages
-
KW2-XXXXXE3 Series
8 Pages
-
KW1-XXXXXE3 Series
8 Pages
-
WA54-220D18K1 Series
6 Pages
-
WA50/60-220XXXK1B Series
4 Pages
-
FA40-220SXXH3 Series
6 Pages
-
UA15-220H05XXXXF2 Series
6 Pages
-
UA12-220SXXD3A Series
5 Pages
-
UA10-220SXXP2 Series
6 Pages
-
U10-220SXXP2D Series
5 Pages
-
FA8-220SXXD2 Series
6 Pages
-
FA6-220SXXD3 Series
6 Pages
-
FA6-220SXXD2 Series
5 Pages
-
FA30-220SXXH2 Series
6 Pages
-
FA25-220SXXH2 Series
7 Pages
-
FA25-220E05XXH2 Series
6 Pages
-
FA20-220H05XXXXH2 Series
6 Pages
-
FA15-380S05H24 Series
6 Pages
-
FA15-220SXXY2 Series
6 Pages
-
CK6-380SXXE2 Series
5 Pages
-
WA3-220SXXA3 Series
5 Pages
-
FA5-220SXXY2 Series
6 Pages
-
FA5-220SXXC2 Series
6 Pages
-
FA5-220EXXXXC2 Series
6 Pages
-
FA3-220SXXA2A series
6 Pages
-
FA2-220SXXA2A Series
6 Pages
-
FA1-220SXXN2 Series
5 Pages
-
FA5-220SXXB-1 Series
7 Pages
-
FA3-220SXXB-1 series
7 Pages
-
UA2-220SXXB series
7 Pages
-
NA200-220SXXM1 Series
3 Pages
-
UA10-220XXXP2 Series
5 Pages
-
UA15-XXXXXF2 Series
5 Pages
-
UA20-220HXXXXXXH2 Series
6 Pages
-
UA15/20-220HXXXXXXF2 Series
5 Pages
-
UA20-220XXXF2/F3 Series
6 Pages
-
UA25-220XXXH2 Series
6 Pages
-
NN2-XXXXXC3N Series
5 Pages
-
NN1-XXSXXANT Series
5 Pages
-
NN1-XXSXXH6 Series
5 Pages
-
NN1-XXXXXBN Series
5 Pages
-
NN1-XXXXXB3N Series
5 Pages
-
NN1-XXSXXAN Series
5 Pages
-
KW3-XXXXXE Series
8 Pages
-
K78XX-500 Series
4 Pages
-
BB40-BB100 Series
4 Pages
-
BA150-BA200 Series
4 Pages
-
AC25-380S12H2 Series
6 Pages
-
FA10-220SXXE2 Series
6 Pages
-
FA20-220HXXXXXXH2 Series
6 Pages
-
FA3-220SXXA2A
6 Pages
-
FA3-220SXXB Series
7 Pages
-
K78XX-1000 Series
4 Pages
-
WA6-220SXXD3 Series
5 Pages
-
WA40/50-220XXXK1 Series
5 Pages
-
FA5-220SXXB Series
7 Pages
-
AC25-H2 Series
6 Pages