CK6-380SXXE2 Series
5Pages

{{requestButtons}}

Catalog excerpts

CK6-380SXXE2 Series - 1

AC/DC Converter CK6-380SXXE2 Series Typical Features ♦ Ultra Wide Input Voltage Range: 165-520V ♦ Over-current, Short-circuit Protection, Self-recovery ♦ Input and Output Isolated 3750V Application Field CK6-380SXXE2 Series--- --a small size, high reliability power converter offered by Aipu. It features high input voltage, DC and AC input dual use, low ripple, low temperature rise, low power consumption, high reliability, safer isolation, with good EMC performance. The series particularly suitable for industrial control, power application. Fuse needed to add before input Live(AC). Please refer to this datasheet when module being used in a bad EMC environment. Product Named Method XX XX-XX X XX X X X —®Suffix Q) Case Material ©Packing Code (5) Output Voltage © Output Ways © Input Voltage (2) Output Power (T) Product Series Typical Product List Model Note: If interest to see more items, please contact with our sales team. Technical Parameters Test Condition: Unless otherwise specified, data in the datasheet should be tested under the conditions of inputting nominal voltage, pure resistance rated load and Ta=25°C. Guangzhou Aipu Electron Technology Co., Ltd Add: B Building , No.4 Courtyard, Qixing Gang, Shiliu Gang, Haizhu Dis, GZ,CN Email: market@aipu-elec.com Tel: 86-20-84206763 Fax: 86-20-84206762 Hotline: 400-811-8032 Website: http://en.aipulnion.com/ Guangzhou Aipu Electron Technology Co., Ltd reserves the copyright and right of final interpretation. Revision: A/0 Date: 2016-9-5 Page 1 of 5

Open the catalog to page 1
CK6-380SXXE2 Series - 2

AC/DC Converter CK6-380SXXE2 Series Input Specifications Input Voltage(Vac) Input Frequency Range(Hz) Stand-by Power Consumption Input Current Inrush Current Output Specifications Output Voltage Accuracy Line Regulation Nominal load, full voltage range Load Regulation Minimum Load Single Output Turn-on Delay Time Nominal input voltage, full load Power-off Holding Time Nominal input voltage, full load Turn on Output Overshooting Output Dynamic Characteristics Overshoot range(%):≤± 5%; Recovery time(mS) ≤5.0mS; 50%-75%-50% Output Short Circuit Protection Continuous, Self-recovery Output Over...

Open the catalog to page 2
CK6-380SXXE2 Series - 3

AC/DC Converter CK6-380SXXE2 Series Class of Case Material Unit: mm(inch); Grid:2.54mm(0.1inch); Printed vertical view General tolerances: ±0.25mm(±0.01inch) Pin tolerances: ±0.10mm(0.004inch) Packing Code Note: If the definition of pin is not in accordance with the model selection manual, please refer to the label on actual item. Ripple& Noise Test: (Twisted Pair Method 20MHZ bandwidth) Test Method: (1) 12# twisted pair to connect, Oscilloscope bandwidth set as 20MHz, polypropylene capacitor and 47uF high frequency low resistance electrolytic capacitor in parallel, oscilloscope set as...

Open the catalog to page 3
CK6-380SXXE2 Series - 4

Temperature Derating Curve Ambient Temperature(°C) Note: I.Output filtering capacitor C1 is electrolytic capacitor, recommend for high frequency and low resistance electrolytic capacitor, capacitance as 100uF/1A output current. Capacitance withstand voltage derating is more than 80%. 2.Output filtering capacitor C2 filters high frequency noise, recommend 1 pF ceramic capacitor, Capacitance withstand voltage derating is more than 80%. 3.TVS is a recommended component to protect post-circuits (if converter fails), recommend 600W model SMBJ20A. 4.NTC is thermistors, recommend model:5D-11, to...

Open the catalog to page 4
CK6-380SXXE2 Series - 5

AC/DC Converter CK6-380SXXE2 Series Below are the recommended specification for Photo 2: 1)MOV is voltage dependent resistor, recommend model: 14D-821K,to protect converter from damage when lightning surge. 2)R1,R2:1MΩ/0.5W; 3)CY1,CY2,CY3,CY4:1000pF/400VAC; 4)CX1, CX2: 0.1μF/275VAC; 5)LCM:10mH-30mH; 6)FUSE: necessary, suggest 1.0A/250V,slow fusing. Note: 1.The product should be used within the specification range, or it will cause permanent damage to it. 2.Product’s input terminal should connect to fuse; 3.If the product is not operated within the required load range, the product...

Open the catalog to page 5

All Guangzhou Aipu Electron Technology Co. catalogs and technical brochures