Catalog excerpts
Product features and functions 1. Temperature control is PID microcomputer automatic calculation intelligent temperature control table, PV/SV display at the same time, can set the required temperature according to the individual's will within the allowable range of machine temperature, and can ensure its control through the PID parameter setting in the table. The accuracy of the temperature can also be calculated by the system itself to obtain the appropriate temperature control parameters. At the same time, the temperature control table can set the 30-stage humidification program to control the heating rate (average humidity, nonlinear no-load). . 2. Warm-in force CA(K) TYPE temperature sensing head, the output is 12V. 3. The current controller adopts the imported thyristor solid state relay (SSR) without contact and no spark phenomenon, which maintains the high stability of the current and automatically adjusts the output ratio through the temperature controller signal.
Open the catalog to page 14. Timer: electronic digital display, timed automatic temperature control, temperature to time, time to cut off the power supply (when the timing switch points to the open position, the actual temperature on the temperature control table -PV value reaches the set temperature - When the SV value is set, the timer starts to work; when the time of the timer reaches the set time, the machine is turned off, the motor power is turned on, and there is an alarm prompt, only the display power supply and the power supply of the control instrument are kept and the cooling speed is accelerated. That is...
Open the catalog to page 2model Temperature control method temperature range Temperature display accuracy Temperature uniformity Studio size(W-D-H) Carton size(W*D«H) Heating rate Temperature Controller Inner box material Outer box material Timing function Insulation material Exhaust flue Thermal insulation device safety equipment Control System Air circulation system using electric test method RLY-1000A Touch screen control + 10~200°C Room temperature (or ambient temperature) +10~200°C ±0.1°C ±2°C 1000*1000*1000mm(or customized according to the size of the battery being tested) 1400*1300*1840mm (5±2)°C/minNonlinear...
Open the catalog to page 3All Guangdong Jian Qiao Testing Equipment Co. catalogs and technical brochures
-
JQ-3F-1000
6 Pages
-
JQ-876
4 Pages
-
JQ-264A
6 Pages
-
JQTHV-1000B
7 Pages
-
JQTHV-1700
5 Pages
-
JQTS3-408
7 Pages
-
JQTS2-50
12 Pages
-
JQESS-225
8 Pages
-
JQT-720
4 Pages
-
JQTHV-3400
7 Pages
-
JQTHV-500
8 Pages
-
JQTHV-1000
5 Pages
-
Impact test bench IS-10
7 Pages
-
Impact test kit JQ18-1
2 Pages
-
Test Fixture
2 Pages
-
Workshop
3 Pages
-
SL0808
6 Pages
-
LIS50
2 Pages
-
JQA-202-335
9 Pages
-
JQA-102-240
8 Pages
-
JQA-021-150
8 Pages
-
JQA-031-150
7 Pages
-
Workshop
6 Pages
-
JQ-1000D
3 Pages
-
JQ-315ST
3 Pages
-
DL-6055
2 Pages
-
JYZC-20
6 Pages
-
DL-815
2 Pages
-
FZ-8201
3 Pages
-
JP-7006
4 Pages
-
DQY-5M3
2 Pages
-
JQ-12M3
3 Pages
-
JQ-5000A
3 Pages
-
HS-6053
3 Pages
-
JQ-8209-12
5 Pages
-
JY-100
5 Pages
-
JQ-8104
2 Pages
-
JQ-8226A
2 Pages
-
JQ-8106
2 Pages
-
JQ-8108
2 Pages
-
JQ-6052
5 Pages
-
JQ-8101
2 Pages
-
JQ-8105
7 Pages
-
JQ-8103
3 Pages
-
JQ-8102
2 Pages
-
Electrodynamic shaker JS-50A
4 Pages
-
Pneumatic crash tester JQQ-50
12 Pages
-
Impact test bench JQJ-50
8 Pages
-
JIAN QIAO Adjustment device
2 Pages
-
Electrodynamic shaker
31 Pages
-
Battery testing chamber
28 Pages
-
climatic chambe catalogue
70 Pages