Catalog excerpts
The heat abuse test chamber is based on the requirements of the test standards such as UL1 642 and IEC621 33. After the battery is fully charged, the battery is placed in the test chamber. The test chamber is heated at a temperature rise rate of (5 ± 2) ° C / min, and the temperature is constant after the temperature in the chamber reaches 130° C ± 2 ° C for 30 min. The battery should not ignite and not explode. Features • This machine adopts PLC touch screen control system, which is convenient and intuitive, fully automatic constant temperature and quick temperature compensation function. • Over temperature protection, overload automatic power off system
Open the catalog to page 1• 4 casters on the bottom for easy movement and fixing • Circulatory system: forced horizontal air circulation • Heating system: PID+S.S.R. • Timing function: When the temperature reaches the set time, the power failure alarm indication • The test area of the test box is a separate test area, the test area size is W600xD500xH600 mm, and the test area box is made of stainless steel SUS304. • The test chamber is provided with an exhaust system. The top of the cabinet is equipped with a blower to discharge the smoke from the test area. • The front door of the test box is reinforced. The left...
Open the catalog to page 2Standards compliant 3.1.GB 31241-2014 "Lithium-ion batteries and battery packs for portable electronic products - Safety requirements" standard requirement: The battery should not ignite or explode After the battery is fully charged according to the specified test method, the battery is placed in the test chamber. The test chamber is heated at a temperature rise rate of (5 ± 2) ° C / min. When the temperature inside the chamber reaches 130 ° C ± 2 ° C, the temperature is constant and lasts for 30 min. Receiving criteria: The battery should not ignite or explode
Open the catalog to page 3All Guangdong Jian Qiao Testing Equipment Co. catalogs and technical brochures
-
JQ-3F-1000
6 Pages
-
JQ-876
4 Pages
-
JQ-264A
6 Pages
-
JQTHV-1000B
7 Pages
-
JQTHV-1700
5 Pages
-
JQTS3-408
7 Pages
-
JQTS2-50
12 Pages
-
JQESS-225
8 Pages
-
JQT-720
4 Pages
-
JQTHV-3400
7 Pages
-
JQTHV-500
8 Pages
-
JQTHV-1000
5 Pages
-
Impact test bench IS-10
7 Pages
-
Impact test kit JQ18-1
2 Pages
-
Test Fixture
2 Pages
-
Workshop
3 Pages
-
SL0808
6 Pages
-
LIS50
2 Pages
-
JQA-202-335
9 Pages
-
JQA-102-240
8 Pages
-
JQA-021-150
8 Pages
-
JQA-031-150
7 Pages
-
Workshop
6 Pages
-
RLY-1000A
3 Pages
-
JQ-1000D
3 Pages
-
JQ-315ST
3 Pages
-
DL-6055
2 Pages
-
JYZC-20
6 Pages
-
DL-815
2 Pages
-
FZ-8201
3 Pages
-
JP-7006
4 Pages
-
DQY-5M3
2 Pages
-
JQ-12M3
3 Pages
-
JQ-5000A
3 Pages
-
HS-6053
3 Pages
-
JQ-8209-12
5 Pages
-
JY-100
5 Pages
-
JQ-8104
2 Pages
-
JQ-8226A
2 Pages
-
JQ-8106
2 Pages
-
JQ-8108
2 Pages
-
JQ-6052
5 Pages
-
JQ-8101
2 Pages
-
JQ-8105
7 Pages
-
JQ-8102
2 Pages
-
Electrodynamic shaker JS-50A
4 Pages
-
Pneumatic crash tester JQQ-50
12 Pages
-
Impact test bench JQJ-50
8 Pages
-
JIAN QIAO Adjustment device
2 Pages
-
Electrodynamic shaker
31 Pages
-
Battery testing chamber
28 Pages
-
climatic chambe catalogue
70 Pages