Catalog excerpts
The high-current short-circuit test device is designed according to the requirements of various battery short-circuit test standards. According to the standard requirements, the short-circuit device must meet the internal resistance range <5mQ, so as to obtain the maximum short-circuit current required by the test; in addition, the circuit design of the short-circuit device must also be able to withstand The impact of high current, so we chose industrial grade DC electromagnetic contactor and all copper terminal and internal copper plate diversion, wide copper plate effectively improve the heat dissipation effect, make the high current short circuit device safer, effectively reduce the loss of test equipment, ensure The accuracy of the test data. Features • High current DC contactor • Turn the DC working voltage to 660V at a long distance • Rated working current 1000A (or 2000A) DC, equipped with a series of magnetic blower cu-bicite arc extinguishing cover arc extinguishing system; • The overall structure of the plane layout, the electromagnetic system and the main contact arc extinguishing system are respectively fixed on the mounting chassis, and the angled rotating electromagnetic system and the double winding attracting coil are used, and the pressing edge device is added on the rotating corner • The main contact is made of copper. Low contact resistance and fast response • The contactor is reliable, safe, long life and easy to maintain. • Remote control: long distance wireless control • Reliable, stable, anti-interference ability, long life • Measuring voltage: 0-100V, to ensure test accuracy • Action mode: 2 points integration method • Measuring current: 0-2000A and 0-1000A DC • Current display accuracy: F.S±0.2% rdg± 1 digit
Open the catalog to page 1Voltage acquisition range: OV — +100V Test subject Power battery unit, module Maximum short circuit current Current resolution Test equipment internal resistance Can withstand short circuit current Equipment test space Temperature acquisition system +/- 5A 0.7 5A <5mQ, 20 mQ (50x 80x 100 mQ, Suitable for current (1000A) 5000A 600X600X600mm Temperature collection range -200—1200 degrees Celsius Temperature acquisition accuracy ± 0.5 ° C Temperature acquisition channel 2 channels Temperature acquisition frequency ^ 300ms Current acquisition system Equipment dimensions Device voltage Current...
Open the catalog to page 2Standards compliant • GB/T 18332.2-2001 "Standard puncture test of metal hydride nickel battery for electric road vehicles" • QC/T 743-2006 Lithium Ion Battery for Electric Vehicles • QC/T 744-2006 Metal hydride nickel battery for electric vehicles • International standards for automotive power batteries (ISO/IEC/SAE/JEVA/CEN, etc.), International Standards Association and "863 Program" Motor vehicle major special test related specifications • QC/T 743-201X Lithium-ion battery for electric vehicles • UL1642 safety standard (lithium battery) • UL2054 safety standard (lithium battery) •...
Open the catalog to page 3All Guangdong Jian Qiao Testing Equipment Co. catalogs and technical brochures
-
JQ-3F-1000
6 Pages
-
JQ-876
4 Pages
-
JQ-264A
6 Pages
-
JQTHV-1000B
7 Pages
-
JQTHV-1700
5 Pages
-
JQTS3-408
7 Pages
-
JQTS2-50
12 Pages
-
JQESS-225
8 Pages
-
JQT-720
4 Pages
-
JQTHV-3400
7 Pages
-
JQTHV-500
8 Pages
-
JQTHV-1000
5 Pages
-
Impact test bench IS-10
7 Pages
-
Impact test kit JQ18-1
2 Pages
-
Test Fixture
2 Pages
-
Workshop
3 Pages
-
SL0808
6 Pages
-
LIS50
2 Pages
-
JQA-202-335
9 Pages
-
JQA-102-240
8 Pages
-
JQA-021-150
8 Pages
-
JQA-031-150
7 Pages
-
Workshop
6 Pages
-
RLY-1000A
3 Pages
-
JQ-1000D
3 Pages
-
JQ-315ST
3 Pages
-
DL-6055
2 Pages
-
JYZC-20
6 Pages
-
DL-815
2 Pages
-
FZ-8201
3 Pages
-
JP-7006
4 Pages
-
DQY-5M3
2 Pages
-
JQ-12M3
3 Pages
-
HS-6053
3 Pages
-
JQ-8209-12
5 Pages
-
JY-100
5 Pages
-
JQ-8104
2 Pages
-
JQ-8226A
2 Pages
-
JQ-8106
2 Pages
-
JQ-8108
2 Pages
-
JQ-6052
5 Pages
-
JQ-8101
2 Pages
-
JQ-8105
7 Pages
-
JQ-8103
3 Pages
-
JQ-8102
2 Pages
-
Electrodynamic shaker JS-50A
4 Pages
-
Pneumatic crash tester JQQ-50
12 Pages
-
Impact test bench JQJ-50
8 Pages
-
JIAN QIAO Adjustment device
2 Pages
-
Electrodynamic shaker
31 Pages
-
Battery testing chamber
28 Pages
-
climatic chambe catalogue
70 Pages