ST300 Inverter User Manual

ST300 Inverter User Manual
1 / 51 PagesView full catalog

ST300 Inverter User Manual

Product catalog summary
Product Information
  • Model Specification: The ST300 series offers models with power grades from 0.75 kW to 2.2 kW, detailing output/input current and adaptive motor power.
  • Technical Data: Specifications include power grade, output/input current, and adaptive motor power for each model.
Function Code Parameter List
  • Motor Parameters: Covers motor rated frequency, speed, number of motors, and self-tuning options, with model-dependent parameters like stator/rotor resistance and no-load current.
  • Input Terminal Selection: Assignable functions include operation modes, fault inputs, and frequency settings.
  • PLC Operation Mode: Simple PLC settings for power failure memory, time unit selection, and stage operation frequency.
  • PID Parameters: Settings for PID channels, feedback, adjustment options, and filtering times, with adjustable proportional gain, integral, and differential times.
  • System Control: Parameters for locking functions, STOP button, and keyboard M key functions.
  • System Protection: Options for fan control, automatic fault reset, and overload alarm detection.
  • Enhanced Functions: Carrier frequency settings and energy braking options.
Overview: The document from Guangdong Dingshen Electric Technology Co., Ltd. details function code parameters and fault countermeasures for their electric technology products, including specifications, status parameters, fault records, and exception handling procedures.
Specifications and Parameters:
  • Voltage and Current Parameters: Specifies voltage/current parameters, including overpressure and overvoltage stall options, with operational values and conditions.
  • Status Parameters: The U00 group includes parameters for analog input status, switch input/output status, machine status, PID settings, bus voltage, output voltage/current, power, torque, temperature, and more, each with a specific code and value range.
Fault Records and Handling:
  • Fault Types: The U01 group records faults like module protection failure, current detection fault, overvoltage, overheating, overload, undervoltage, phase loss, etc., each with a numeric code.
  • Fault Countermeasures: Chapter 3 outlines countermeasures for each fault type, including checking connections, adjusting settings, seeking technical support, and replacing faulty components, with specific causes and solutions for each fault code.
Software and Production Information:
  • Software Version: The U02 group lists product series, software versions, rated power, voltage, current, and production details.
Key Recommendations:
  • Ensure proper parameter settings and regular maintenance to prevent faults.
  • Follow specified procedures for fault handling and seek professional support when necessary.
  • Regularly update software and check compatibility with hardware components.
Specifications and Procedures:
The document outlines the communication protocol for the ST300 series inverter by Guangdong Dingshen Electric Technology Co., Ltd., using a single RS485 communication interface with the MODBUS protocol for operations like reading/writing function parameters and control commands. The inverter operates in slave mode during communication.

Transport Details:
The RS485 interface is asynchronous, half-duplex, with high bytes first and low bytes last. The factory default format and baud rate are 1-8-1-N, 9600bps.

Address Correspondence and Function Definition:
Includes a register distribution for the frequency converter, detailing control parameters not saved during power failure, such as control command word, principal frequency setting, electric torque limit, and regenerative torque limit.

Control Command Word Definitions:
Defines operational states like running command validity, forward/reverse turn, deceleration, emergency shutdown, and fault reset.

Special Instructions:
Data frames in ASCII format with even frame lengths are discarded. Avoid multiple multi-function input terminals with the same settings to prevent functional disorder. Parameters with negative values are handled uniquely, with specific data read values for negative inputs.

Contact Information:
Operational Address: No. 118, Liangle Road, Gujian Village, Daliang Street, Foshan, Guangdong, China. Telephone: 0757-22613860, Fax: 0757-22613860.
See more

Catalog excerpts

ST300 Inverter User Manual-1

USER MANUAL ST300 Series frequency converter

 Open the catalog to page 1
ST300 Inverter User Manual-3

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 1 Product information Chapter 1 Product information 1.1 Model specification 1.2 Product model and technical data Inverter model ST300-2S0.75G Power grade Output current Input current Adaptive motor (kW) (A) (kW) (A) 0.75

 Open the catalog to page 3
ST300 Inverter User Manual-6

Control board terminal function TB

 Open the catalog to page 6
ST300 Inverter User Manual-14

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list P02.03 Motor rated frequency The number of motor Motor parameters self-tuning selection Motor stator resistance Motor rotor resistance Leakage inductance of motor Motor mutual inductance No-load current of motor Models to 0x0208 determine Models to 0x0209 determine Models to 0x020A x determine Models to 0x020B x determine Models to 0x020C x determine P06 group switching quantity X1 input terminal selection X2 input terminal selection 00: No function 01: positive turn point movement 02: Reverse point 03: Positive...

 Open the catalog to page 14
ST300 Inverter User Manual-15

Guangdong Dingsheng Electric Technology Co.,Ltd Chapter 2 Function code parameter list 11: multi-segment frequency terminal 4 12: Switch to panel control by X3 input terminal running a command P06.02 selection 13: Switch to terminal control by running commands X4 Input terminal selection 14: Run the command to switch to communication control 15: Frequency source given switch 16: Switch the main frequency source to frequency digital setting 17: Switch the auxiliary frequency source to frequency digital setting 18: The terminal adjustment is UP 19: Terminal adjustment minus DN 20: UP/DN setting...

 Open the catalog to page 15
ST300 Inverter User Manual-16

Guangdong Dingsheng Electric Technology Co.,Ltd Chapter 2 Function code parameter list 11: multi-segment frequency terminal 4 12: Switch to panel control by X3 input terminal running a command P06.02 selection 13: Switch to terminal control by running commands X4 Input terminal selection 14: Run the command to switch to communication control 15: Frequency source given switch 16: Switch the main frequency source to frequency digital setting 17: Switch the auxiliary frequency source to frequency digital setting 18: The terminal adjustment is UP 19: Terminal adjustment minus DN 20: UP/DN setting...

 Open the catalog to page 16
ST300 Inverter User Manual-25

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list Simple CHOICE P13.00 of PLC operation mode Hundreds: simple PLC power off memory 0: power failure reset 1: Power failure storage Thousands: simple PLC time unit 0: seconds (s) 1: minutes (min) Bits: simple PLC stage operation frequency 0: multi-segment frequency 0 (P12.00) 1: AI1 analog input 2: AI2 analog input 3: DI/X4 pulse input is given 4: Process closed-loop PID 5: Communication is given 6: multi-speed Phase 0 running time Ten:simple PLC stage running direction 0: positive 1: reverse 2: the value is determined...

 Open the catalog to page 25
ST300 Inverter User Manual-26

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list Bits: simple PLC stage operation frequency 0: multistage frequency 2 (P12.02) For other Settings, refer to Phase 0 Phase 2 running time Bits: simple PLC stage operation frequency 0: multistage frequency 3 (P12.03) For other Settings, refer to Phase 0 Phase 3 running time Bits: simple PLC stage operation frequency 0: multistage frequency 4 (P12.04) For other Settings, refer to Phase 0 Phase 4 P13.10 running time P13.11 Bits: simple PLC stage operation frequency 0: multistage frequency 5 (P12.05) For other Settings,...

 Open the catalog to page 26
ST300 Inverter User Manual-27

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list P13.18 Phase 8 run time Bits: simple PLC stage operation frequency 0: multi-segment frequency 9 (P12.09) For other Settings, refer to Phase 0 Phase 9 running time Bits: simple PLC stage operation frequency 0: multi-segment frequency 10 (P12.10) For other Settings, refer to Phase 0 Bits: simple PLC stage operation frequency 0: multi-segment frequency 11 (P12.11) For other Settings, refer to Phase 0 Phase 11 running time Bits: simple PLC stage operation frequency 0: multi-segment frequency 12 (P12.12) For other...

 Open the catalog to page 27
ST300 Inverter User Manual-28

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list Phase 14 run time Bits: simple PLC stage operation frequency 0: multi-segment frequency 15 (P12.15) For other Settings, refer to Phase 0 P15 process closed-loop PID parameters P15.00 PID positive and negative action PID Specifies P15.05 the filtering time PID feedback P15.06 filtering time PID output P15.07 filtering time P15.08 0: Digital setting (P15.01) 1: AI/AV analog input 4: Communication is given 0.0% - 100.0%. 0: AI/AV analog input 3: communication is given Tens place: integral mode 0: frequency to upper...

 Open the catalog to page 28
ST300 Inverter User Manual-29

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list The integral time is Ti1 Differential P15.10 time Td1 0: use only Kp1, Ki1, and Kd1 1: Automatically switches according to the input deviation 2: Switches based on terminals Input deviation of PID automatic switchover PID deviation P15.17 limit PID differential P15.18 limiter PID initial hold P15.20 time PID operation P15.21 output maximum value PID reverse P15.22 output cutoff frequency PID shutdown P15.23 operation selection 0: no operation is performed when the machine is stopped. 1: Operation is performed...

 Open the catalog to page 29
ST300 Inverter User Manual-30

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list PID is given a P15.24 loss-detection value PID Indicates P15.25 the lost detection time 0.00 s to 30.00 s, 0.00 s:does not detect PID given loss 0.00 s to 30.00 s 0.00 s: Does not detect PID feedback loss PID feedback P15.26 lost the check value PID feedback P15.27 lost the check out time P15.28 PID signal loss shutdown mode 0: free shutdown 1: emergency shutdown PID Running P15.29 wake up frequency P15.30- Upper limit frequency PID Running P15.30 hibernation frequency P16 group keyboard display parameters 00:...

 Open the catalog to page 30
ST300 Inverter User Manual-31

Guangdong Dingshen Electric Technology Co.,Ltd Chapter 2 Function code parameter list Display contents in the running state of the keyboard 5 Display contents in the running P16.05 state of the keyboard 6 Display content 1 P16.06 when the keyboard is down Display content 2 P16.07 when the keyboard is down Display content 3 P16.08 when the keyboard is down Display contents P16.09 in shutdown state of keyboard 4 Display contents P16.10 5 when the keyboard is down 22: Set the frequency 23: operating frequency 25: Main setting channel 26: auxiliary setting channel 27: Main set frequency 28: Auxiliary...

 Open the catalog to page 31