Temperature Test Chamber(Walk in )A tt Standard Compliance Test Space WxHx D (mm) Temperature Range A Type: O-90^C, B Type: -20^90*0. C Type: -4090*0, D Type:-70-9CTC HumldityRange 20%RH-98%RH (Low humidity ; 5%RH available) Humidity Deviation <+2/3%R.H. (Humidity >75%RH) , < ± 5RH% (Humidity < 75%RH) HeotingRoie Approx 1 - 3^/mtns p average non-linear ,no load CoolingRate Approx0,5- PC/mins, average non-linear,no load Internal Material l .Omm thickSUS#304 high &low temperature resistance stainless steel. External Material l .2mm thickness High temperature spray powder coated galvanized plate Tecumseh (France)-fully air-cooled double-fall cooling compressor. Or Bock (Germany) semi-enclosed air-cooled refrigeration. Dry air purge system .Humidifying water auto purifying and supply system. New air ventilation system ,Fire-proofr explosion-proof & alarm system .Low temperature low humidity, low temperature high humidity test requirement. Remote computer, mobile alarm function