1. Catalogs
  2. Guangdong Bell Experiment Equipment Co., Ltd
  3. Power Battery short circuit test machine Short Circuit-BE-XL-ADZ

Power Battery short circuit test machine Short Circuit-BE-XL-ADZ

Power Battery short circuit test machine Short Circuit-BE-XL-ADZ

Product catalog summary
Overview: The document describes the specifications and testing procedures for the Large Current Battery Short Circuit Testing Machine, available in two models: BE-XL-10000A and BE-XL-15000A.
Specifications:
  • Models: BE-XL-10000A and BE-XL-15000A
  • Max Operating Current: 10000A for BE-XL-10000A, 16000A for BE-XL-15000A
  • Max Transient Current: 12000A for BE-XL-10000A, 16000A for BE-XL-15000A
  • Temperature Range: Ambient Temperature
  • Inner Resistance Options: <1mΩ, <5mΩ, <10mΩ, <20mΩ, <50mΩ, <100mΩ
  • Control Mode: PLC touch screen, computer remote control, remote control
  • Dimensions: External - W700xD1050xH1830mm; Explosion-proof Cabinet - W2000xD3000xH2000mm (optional)
  • Voltage Measurement Range: 0~1000V
  • Short Circuit Response Time: ≤20ms
  • Data Interface: USB, Data card
  • Safety Devices: Video monitor, explosion protection, smoke exhaust, smoke alarm, explosion-proof lighting
  • Data Acquisition: Independent remote acquisition, multi-channel, 100Hz frequency
  • Short Circuit Method: Pneumatic + vacuum arc extinguishing
  • Safety Alarm Devices: Electric leakage, over-current protection, sound-light alarm, smoke alarm
  • Power Supply: 220V 50Hz
Testing Procedures:
  • Test Object: Battery pack and system
  • Test Conditions:
    • Temperature should be 20±10°C or higher
    • All protective devices must be operational
    • Main contactors for charging/discharging should be closed
    • Positive and negative terminals connected to create a short circuit with resistance not exceeding 5mΩ
  • Completion Conditions:
    • Protection function activates and terminates current
    • Temperature stabilizes with a gradient <4°C over 2h, continue for at least 1h
  • Post-Test Observation: Observe for 2h at room temperature
See more

Catalog excerpts

Power Battery short circuit test machine Short Circuit-BE-XL-ADZ-1

Large Current Battery Short Circuit Test chamber Large Current Battery Short Circuit Testing Machine Large Current Battery Short Circuit Tester Performance parameters Model BE-XL-10000A BE-XL-15000A Max. Operating Current 10000A 16000A Max. Transient Current Temp. Range Ambient Temperature Inner Resistance <1mΩ, <5mΩ, <10mΩ, <20mΩ, <50mΩ, <100mΩ (Optional) Control Mode Close PLC touch screen control + computer remote control + remote control External Dimension W700xD1050xH1830mmwW700xD1050xH1830mm Explosion-proof Cabinet Dimension W2000xD3000xH2000mm (Option) Voltage Measurement Range 0~1000V Short Circuit Response Time ≤20ms Data Interface USB, Data card, etc... Safety device Video monitor system, explosion protection system, smoke exhaust system, smoke alarm device, explosion proof lighting device, etc. Data Acquisition Module Independent remote acquisition and quarantine, multi-voltage/temperature/current acquisition channels ensure data accuracy. Acquisition frequency 100HZ Short Circuit Method Pneumatic + vacuum arc extinguishing Safety Alarm device Electric leakage, over-current protection, abnormal sound-light alarm, smoke alarm, dual protection system, etc. Testing Fixture Customize according to actual testing condition Power Supply 220V 50Hz Related Standard Test Requirements 1.Test object: battery pack and system 2. Test conditions: 2.1 Test temperature should be at the 20+ 10°C or higher. (According to battery system manufacturer’s request). 2.2 All protective devices that affect the function of the test objects and related to the test results shall be in normal operation when test start. 3.The main contactors used for charging and discharging should be closed to indicate the feasible vehicle mode and the mode of allowing external charging. If is it not available to be completed in one single test, process two or more tests. 4. The positive and negative terminals of the test object being connected to each other to create a short circuit. The resistance of the connection (including wiring) which used to create short circuit should not exceeding 5mΩ. 5.Keep short circuit until any of the following conditions are met and the test is completed. 5.1 The protection function of the test object works and the short circuit current is terminated. 5.2 After the temperature of the test object's shellis stable (the temperature gradient is less than 4°C within 2h), the short circuit will continue for at least 1h. 6.After testing, observe for 2h under the room temperatu

 Open the catalog to page 1

All Guangdong Bell Experiment Equipment Co., Ltd catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.