Lithium Battery 4 zone High and Low Temperature Test Chamber THERMALBTLD4
2Pages

{{requestButtons}}

Catalog excerpts

Lithium Battery 4 zone High and Low Temperature Test Chamber THERMALBTLD4 - 1

Four-deck High and Low Temperature Test Chamber ♦ Internal Size (W x D x H) mm 850*850*400 BTL-D4-289C Extraordinary production performance brings more business.Performance Parameter BTL-D4-289C Structure Air Supply Mode Temperature Range Temperature Fluctuation Heating Rate Cooling Rate Temperature Uniformity Temperature Deviation Observation Window Testing Terminal Cooling Method Compressor Control Internal Material External Material Power Supply Voltage Safety Protection Four working chambers in an integral design (customizable to left and right structures) Forced internal circulation, horizontal air delivery -40*C-+150°C ±0.5°C Average of l~3°C/minute throughout the process (non-linear, without load) Average of l°C/minute throughout the process (non-linear, without load) <2°C (without load, at constant state) <±2°C W300 X H400 MM, triple-layer vacuum toughened glass 12 sets of terminals installed inside and outside the box on the left side for connection with test cabinet Optional air cooling or water cooling French Tecumseh compressor PLC programmable control with touch screen, USB interface, RS485 interface for PC control, specialized network control software for remote monitoring and data acquisition 1.0mm SUS304 stainless steel 1.2mm cold roll steel powder-sprayed, high-temperature plasticized AC380V50HZ Automatic explosion-proof pressure relief device, explosion-proof chain, tri-color lamp alarm device, remote control, smoke exhaust device, fire extinguishing device, etc.

Open the catalog to page 1
Lithium Battery 4 zone High and Low Temperature Test Chamber THERMALBTLD4 - 2

Structure Air Supply Mode Temperature Range Temperature Fluctuation Heating Rate Cooling Rate Temperature Uniformity Temperature Deviation Observation Window Cable Port Cooling Method Compressor Control Method Inner Chamber Material Outer Chamber Material Power Safety Protection Communication Protocol Testing chamber is designed with a three-compartment structure (upper, middle, and lower compartments) Forced internal circulation, from upper to lower air supply circuilation B: -20°C to +150T C: -40°C to +150°C ±0.5°C Average l~3°C/min full range (non-linear, no load) Average lT/min full...

Open the catalog to page 2

All Guangdong Bell Experiment Equipment Co. catalogs and technical brochures

Archived catalogs