Performance Parameters
  • Model: BTH-1000D
  • Effective Volume: 1000L
  • Internal Dimensions: W1000 x H1000 x D1000mm (customizable)
  • External Dimensions: W1200 x H2250 x D2400mm (including motor height)
  • Temperature Range: -70°C to +150°C (customizable)
  • Humidity Range: 20%RH-98%RH
  • Temperature Fluctuation: ±0.5°C
  • Humidity Fluctuation: ±2.5%RH
  • Temperature Deviation: ≤±2.0°C
  • Humidity Deviation: ≤+2,-3%RH (Humidity>75%RH), ≤±5%RH (Humidity<75%RH)
  • Temperature Uniformity: ≤±1.0°C
  • Heating Rate: 0.1~1.2°C/min (from -40°C to +80°C)
  • Cooling Time: 0.1~1.2°C/min (from -40°C to +80°C)
  • Temperature Overshoot: ≤±2°C
  • Maximum Load: 20KG
  • Noise Level: ≤70dB (A level)
  • External Material: Galvanized sheet with high temperature electrostatic resin coating
  • Internal Material: 1.2 mm SUS# 304 stainless steel
  • Control Method: Touch screen programmable PLC with USB and RS485 interfaces
  • Compressor: Semi-Hermetic Compressors BOCK (Germany)
  • Observation Window: 3-layer vacuum glass with anti-frosting and anti-condensing features
  • Power Supply: AC 380V 50HZ 14.0KW
  • Auxiliary Functions: Explosion-proof devices, mobile phone alarm, networking, smoke exhaust, fire extinguishing
Related Standard Test Requirements
  • Test Object: Li-ion cell battery
  • Charging Method: According to method 7.1.1
  • Testing Procedure: Place battery in chamber, adjust temperature as per table 1 and figure 2, conduct 5 cycles
  • Post-Test Observation: Observe for 1 hour under testing temperature
Schematic Diagram of Temperature Cycle Test
  • Temperature Cycle: Varies from 29°C to 85°C with specific time increments
  • Time Increments: Detailed in minutes for each temperature phase
See more

Catalog excerpts

Environmental Temperature Cycling test chamber BTH-1000D-1

Temperature Cycling Test Chamber Performance parameters Model BTH-1000D Effective Volume 1000L Internal Dimension W1000 X H1000 X D1000mm (Can be customized) External Dimension W1200 X H2250 X D2400mm (including the motor height for the top of the chamber) Temperature Range -70°C ~ +150°C (Can be customized) Humidity Range 20%RH-98%RH (Limit temperature section, see the regional figure ) Temperature Fluctuation ± 0.5°C Humidity Fluctuation ±2.5%RH — Temperature Deviation ≤±2.0°C Humidity Deviation ≤+2,-3%RH (Humidity>75%RH) , ≤ ±5%RH (Humidity<75%RH) Temperature Uniformity ≤± 1.0°C Heating Rate 0.1~1.2°C /min(From -40°C up to +80°C ,average, linear with load) Cooling time 0.1~1.2°C/min(From -40°C up to +80°C average, linear with load) Temperature Overshoot ≤± 2°C Maximum Load 20KG Constant Max. Heating Load No Noise ≤70dB (A level) External Material Internal Material Control Method Galvanized sheet with high temperature electrostatic resin coating at both sides. 1.2 mm thickness SUS# 304 heat and cold resistant stainless steel with seal welding. Touch screen programmable PLC, with USB interface, with RS485 interface can be connected to computer controlling, special network control software, convenient remote monitoring, data acquisition. Compressor Semi-Hermetic Compressors BOCK (Germany)Observe Window With 3-layers vacuum glass observation window on the door(W430mm*H580mm) ;Door frame with electric heat function (auto adjustable), anti-frosting, antfi-condensing devices, ensures clear observation of the specimen under testing Power Supply AC 380V 50HZ 14.0KW Auxiliary fuction Explosion-proof pressure relief device, explosion-proof chain, mobile phone alarm device, networking, smoke exhaust device,fire extinguishing device, etc. Related Standard Test Requirements 1.1 Test object: Li-ion cell battery. 1.2The test battery should be charged according to the method 7.1.1. 1.3 Put the test battery into the temperature chamber, temperature of the chamber adjusted according to table 1 | and figure 2, test 5 cycles 1.4 After testing, observe for 1h under the testing temperature.

 Open the catalog to page 1

All Guangdong Bell Experiment Equipment Co., Ltd catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.