POWER FACTOR CONTROLLER

POWER FACTOR CONTROLLER

Product catalog summary
Technical Features Overview
  • Optimum Step Value Recommendation: Utilizes advanced Reactive Power Profile (RPP) analysis to suggest optimal step values.
  • Preventive Maintenance: Includes infrastructure for preventive maintenance with detailed logging of events, warnings, and errors, complete with date and time stamps.
  • Power Factor Correction: Ensures safe and continuous correction with dynamic step diagnosis.
  • Display: Features a 3.5" colorful TFT display with a smart menu and user-friendly interfaces.
  • Setup Assistant: Facilitates quick configuration and installation start.

Power Factor Controller Specifications
  • Three-phase Power Supply: Operates with voltage on any phase.
  • Design: Slim ergonomic design with a total depth of 42 mm inside the panel.
  • Compensation and Response: Offers compensation recovery and continuous response with failure detection.
  • Bidirectional Compensation: Supports energy consumption and generation.
  • Monitoring: Monitors generator consumption and line magnitudes with different indices.
  • Measurement Capability: Measures up to the 63rd harmonic for current and voltage.
  • Hybrid Compensation: Provides hybrid compensation with SVC steps and a 10,000 step resolution.
  • Automatic Matching: Features automatic current-voltage matching and current direction detection.
  • Setup Options: Includes options for capacitor, reactor, or SVC steps, and single current transformer setup.
  • Protection: Offers compensation protection under various conditions such as low voltage, over voltage, and over temperature.
  • Reactive Power Setting: Allows temporary and permanent settings for unmetered reactive power.
  • Cos φ Setting: Provides temporary and permanent target Cos φ settings, with different settings when the generator is on.
  • Hybrid Compensation: Differentiates step groups’ discharge times using both contactors and thyristors.
  • Voltage Level Management: Manages AC/DC voltage levels of step groups’ supply commons.
  • Sensitivity: Recognizes 3-phase capacitor/reactor at 500 VAr with 1000/5 current transformers.
  • Co-aging Option: Available for steps.
  • Safe Hardware: Ensures safety against connection failures in voltage, current, step commons, and thermal inputs.
See more

Catalog excerpts

POWER FACTOR CONTROLLER-1

POWER FACTOR CONTROLLER Setup Assistant 3.5" Colorful TFT Display Dynamic Step Diagnosis Optimum Step Value Recommendation Preventive Maintenance with Daily Records Safe and Continuous Power Factor Correction TECHNICAL FEATURES ▪ Three-phase power supply technology that can operate as long as there is voltage on any phase. ▪ Slim ergonomic design with a total depth of 42 mm inside the panel including terminal blocks. ▪ Compensation recovery and continuous response with detection of voltage and current connection failure. ▪ Dynamic diagnosis of compensation steps and automatic value update ▪ Bidirectional compensation for energy consumption and generation ▪ Monitoring generator consumption and line magnitudes with indices different from network indices when the utility is fed from the generator ▪ High resolution colorful, fast and smooth TFT display with smart menu and user-friendly interfaces. ▪ Measurement up to 63rd harmonic for current and voltage ▪ Hybrid compensation with SVC steps with 10,000 step resolution ▪ Automatic current-voltage matching and current direction detection with three-phase and single-phase steps in installation. ▪ Quick configuration of device parameters and start installation with the Setup Assistant. ▪ Setup option with capacitor, reactor or SVC steps only ▪ Setup and compensation option with single current transformer ▪ Compensation protection in low voltage, over voltage, over harmonic, over temperature conditions ▪ Temporary / Permanent inductive and capacitive unmetered reactive power setting for loads measured by the operating meter but not seen by the compensation system ▪ Temporary and permanent target Cos φ setting. ▪ Different Cos φ2 setting when the generator is on. ▪ Hybrid compensation with both contactors and thyristors by differentiating step groups’ discharge times ▪ Measurement, control and management of the AC/DC voltage levels of the step groups’ supply commons ▪ Optimum step value recommendation through advanced Reactive Power Profile (RPP) analysis ▪ Sensitivity to recognize 3-phase capacitor/reactor at 500 VAr with 1000/5 current transformers ▪ Co-aging option for steps ▪ Safe hardware against connection failure in voltage, current, step commons and thermal inputs ▪ Preventive maintenance infrastructure with detailed event/warning/error logging support with date and ti

 Open the catalog to page 1

All Grup Arge Energy and Control Systems catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.