Relay 715

Relay 715

Relay 715

Product catalog summary
Description: The Relay 715 is a polarized latching relay featuring a position display and a manual operation switch. It utilizes the H-armature principle, providing high resistance to shocks and vibrations, ensuring a defined switching position without information loss during power failures. The relay operates with a pulse-driven mechanism, minimizing coil heating, and can be manually set.
Specifications:
  • Coil Data: Rated voltage ranges from 6 to 24 VDC, with a rated power of 0.5 W and operating power to set at 0.3 W. The pulse to set is 20 ms, with an action time of less than 10 ms.
  • Contact Data: Maximum contact arrangement is 1 c / 1 a, using AgSnO2 contact material. It supports a maximum switching power of 4,000 VA, voltage of 440 VAC, and current of 16 A. The mechanical life is rated at 106 operations.
  • Insulation: Creepage and clearance distance between coil and contact is 8 mm, with a test voltage of 4,000 V eff. Dielectric strength between coil and contact is 12 kV / 1.2 / 50 µs.
  • General Data: Operates within an ambient temperature range of -25 to +70 °C and weighs 12 g. It conforms to VDE, UL, CSA, SEV, and SEMKO standards.
Technical Drawing: The document includes a technical drawing illustrating the relay's dimensions and terminal grid layout.
Ordering Information: The relay can be ordered with various options such as a closed cover, manual operation switch, and position indicator. Contact material options include AgSnO2, with contact arrangements of normally open or change-over switch.
Standard Windings: The relay coil can be configured as a double or single winding. Standard winding numbers and their corresponding nominal coil voltages, operating voltages, and resistances are provided.
Soldering Advice: The relay is dust-protected, and care should be taken to prevent flux medium and lead-tin evaporations from entering the relay during soldering.
See more

Catalog excerpts

Relay 715-1

Technical Data Polarized latching relay, with position display and switch Using the H-armature principle the polarised latching relays are noted for their high resistance to shocks and vibrations. They are always in a defined switching position and therefore there is no loss of information in case of power failure. The advantage of polarised latching relays is the pulse driven operation of some milliseconds, coil heating can be neglected. Relay can also be set by manual operation. The relays are designed and manufactured in accordance to international standards of IEC 61810 part 1/VDE 0435 Technical data Coil data Rated voltage 6-24 VDC Test voltage contact - contact open contact coil - contact General data Ambient temperature -25 ...+70 °C

 Open the catalog to page 1
Relay 715-2

Standard windings Standard winding No. Nominal coil voltage Operating voltage of the coil Coil resistance Double winding The relay coil with double winding can also be used as a single winding with half operating power if the middle pin of the coil is not used. Identification code Type A = cover closed M = manual operation switch MI = position indicator Contact material Contact arrangement 1A = 1 normally open 1U = 1 change-over switch Further versions on request A = double winding see coil table Advice for soldering: The relay is dust-protected. Take care to avoid that flux medium and lead-tin...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.