GRUNDFOS DATA BOOKLET Chlorine gas dosing systems

 Open the catalog to page 1
Vaccuperm VGA and VGB-2

Principle of vacuum chlorine gas dosing systems 4 Vaccuperm VGB-103 compact dosing unit 15 Vaccuperm VGA-111 vacuum regulator 16 Vaccuperm VGA-113 dosing regulator 17 Vaccuperm VGA-146 vacuum regulator 18 Vaccuperm VGA-117 dosing regulator 19

 Open the catalog to page 2
Vaccuperm VGA and VGB-3

Equipment features Performance diagram Performance diagram Vaccuperm VGA, VGB, VGS Please select your Vaccuperm chlorine gas dosing system according to this diagram.

 Open the catalog to page 3
Vaccuperm VGA and VGB-4

General data Principle of vacuum chlorine gas dosing systems Principle of a vacuum chlorine gas dosing system Vacuum regulator Dosing regulator Adsorption cylinder (option) Safety valve (option) Dosing regulator (C) The chlorine gas volume flow is adjusted with the dosing regulator. This can be effected manually or automatically via motor control. VGB models combine a vacuum regulator and a dosing unit in a compact enclosure. They are not available with change-over device or servomotor for dosing regulator. Change-over device (option) Water apparatus (option) Injectors have the task to bring...

 Open the catalog to page 4
Vaccuperm VGA and VGB-5

2. Construction and function Vaccuperm VGB-103 Vaccuperm VGB-103 compact unit • Vacuum regulator and dosing regulator in a single unit for direct mounting on a chlorine cylinder. • Up to 2000 g/h can be extracted. The maximum extraction quantity depends on the chlorine cylinder content: It is 1 % per hour of the content by weight. For a short time (max. 10 minutes) it is possible to extract the triple of this. 1 Vaccuperm VGB-103 with USA yoke Vaccuperm 103-100 Chlorine gas adsorption cylinder Injector

 Open the catalog to page 5
Vaccuperm VGA and VGB-6

Vaccuperm VGA-111, VGA-113, VGA-146, VGA-117 Dosing station for extraction from one drum • Vacuum regulator for direct mounting on a chlorine cylinder. • Dosing regulator for separate wall mounting. • Vacuum regulator for wall mounting (in the drum room). • Dosing regulator for separate wall mounting. • It is recommended to wrap a heater band around the copper line between the container and the vacuum regulator when using drums. Dosing station for extraction from one cylinder (VGA-111 and VGA-113) Vacuum regulator VGA for direct mounting Dosing regulator VGA for serial installation Injector with...

 Open the catalog to page 6
Vaccuperm VGA and VGB-7

Dosing station for simultaneous extraction from several cylinders (full vacuum system) Combination of several VGA-111 and VGA-113 • If more gas is required, it can be extracted from several cylinders simultaneously. • Vacuum regulators are installed on several chlorine cylinders in series using T-pieces. • Single or multiple dosing regulators for separate installation. 2 Fig. 10 Dosing station for simultaneous extraction from several cylinders (VGA-111 and VGA-113) Pos. Component 1 Vacuum regulator VGA for direct mounting Dosing regulator VGA for serial installation Injector with diaphragm check...

 Open the catalog to page 7
Vaccuperm VGA and VGB-8

Dosing station with vacuum change-over device Combination of several VGA-111 and VGA-113 • Continuous gas dosing without interrupting the process. • Two vacuum regulators for mounting on gas cylinder header lines. • Up to 4 dosing regulators can be installed separately. • If the first cylinder row is empty, the change-over device immediately changes over to the next vacuum regulator at the full chlorine cylinder row. • The safety valve avoids excess pressure in the vacuum lines leaving the cylinder room. 1b Vacuum regulator VGA with liquid trap for wall mounting 2 Dosing regulator VGA for serial...

 Open the catalog to page 8
Vaccuperm VGA and VGB-9

Dosing station for simultaneous extraction from several cylinders, if more than 4000 g/h are required in total Combination of several VGA-146 and VGA-117 • If more gas is required, it can be extracted from several cylinders simultaneously. • Vacuum regulators for mounting on header lines. • With automatic change-over device. Vacuum regulator VGA with liquid trap for wall mounting Dosing regulator VGA for serial installation Dosing regulator VGA with electric servomotor Dosing regulator VGA with electric servomotor and current input Injector with diaphragm check valve Vacuum change-over device...

 Open the catalog to page 9
Vaccuperm VGA and VGB-10

Dosing station with vacuum change-over device Combination of several VGA-146 and VGA-117 • Continuous gas dosing without interrupting the process. • Two vacuum regulators for mounting on chlorine drums, liquid traps avoid the penetration of liquefied gas. • Several dosing regulators can be installed separately. • If the first drum is empty, the change-over device immediately changes over to the next vacuum regulator at the full chlorine drum. • The safety valve avoids excess pressure in the vacuum lines leaving the drum room. Fig. 13 Dosing station with vacuum change-over device (VGA-146 and...

 Open the catalog to page 10
Vaccuperm VGA and VGB-11

Inlet valve B simple 1 with pressure gauge Filter O external

 Open the catalog to page 11
Vaccuperm VGA and VGB-12

Vaccuperm VGA-111Example VGA-111 -B /1 -S -0 R -0 -U , N F VGA Vaccuperm Gas Advanced Installation B directly on the chlorine gas cylinder C on a header line BC directly on the chlorine gas cylinder or on a header line Inlet valve B simple L long, 230-240 V / 50-60 Hz, with liquid trap and heater M long, 110-115 V / 50-60 Hz, with liquid trap and heater 1 with pressure gauge Filter O external

 Open the catalog to page 12
Vaccuperm VGA and VGB-13

Example VGA Vaccuperm Gas Advanced 2 direct control with 1000 Ohm feedback potentiometer manual automatic, 230-240 V / 50-60 Hz (not for 25 g/h) automatic, 110-115 V / 50-60 Hz (not for 25 g/h) Connection input and output 5 PE hose 8/11 mm 7 PVC pipe DN 15 (external diameter 20 mm) 2 direct control with 1000 Ohm feedback potentiometer

 Open the catalog to page 13
Vaccuperm VGA and VGB-14

Type key Vaccuperm VGA-146 Example VGA-146 -D /1 /6 -S -0 R F Installation D directly on the chlorine gas drum C on a header line DC directly on the chlorine gas drum or on a header line 7 PVC pipe DN 15 (external diameter 20 mm) Inlet valve S short 1 with pressure gauge Connection pressure gauge T top Pressure input F front

 Open the catalog to page 14
Vaccuperm VGA and VGB-15

4. Technical data Vaccuperm VGB-103 compact dosing unit Technical data Medium Capacity ranges Adjustment ratio Measuring device According to the floater principle, measuring tube 70 mm Empty indication Automatical visible signal for lack of chlorine Enclosure: PVC Inlet valve: Silver/PTFE, special alloy Springs: Coated with nickel-chrome alloy Diaphragm: FEP Rate valve: PVC O rings: FKM Yoke: Cast iron, nickel plated Pressure side (chlorine gas): G 3/4; G 1, yoke Vacuum safety line: PE hose 8/11 mm Connections Weight • Manometer 0 to 16 bars, NG 63 • Internal filter inside the vacuum regulator...

 Open the catalog to page 15

All GRUNDFOS catalogs and technical brochures

  1. GRUNDFOS ALPHA2

    20  Pages

  2. Grundfos ALPHA1

    24  Pages

  3. ALPHA1 L

    2  Pages

  4. DME

    2  Pages

  5. UPM3

    92  Pages

  6. GRUNDFOS UPM3

    11  Pages

  7. CRN MAGdrive

    2  Pages

  8. GRUNDFOS CRE

    2  Pages

  9. TPE3

    7  Pages

  10. CIM/CIU

    3  Pages

  11. BMS

    5  Pages

  12. BM

    2  Pages

  13. BACMON

    16  Pages

  14. AQtap

    7  Pages

  15. ALPHA2 L OEM

    19  Pages

  16. CRE GRUNDFOS

    2  Pages

  17. MTA

    3  Pages

  18. Unilift CC

    2  Pages

  19. ALPHA1

    2  Pages

  20. AMD-AMG-AFG

    3  Pages

  21. HS

    5  Pages

  22. SQ

    3  Pages

  23. MAGNA/UPE

    12  Pages

  24. Selcoperm SES

    20  Pages

  25. Conex DIS-G

    2  Pages

  26. Conex DIS-C

    2  Pages

  27. Sololift2

    9  Pages

  28. VGA and VGB

    28  Pages

  29. Oxiperm Pro

    8  Pages

  30. DMX

    18  Pages

  31. DMH

    18  Pages

  32. MP 204

    3  Pages

  33. TP/TPE

    5  Pages

  34. SP Product

    7  Pages

  35. S-Tube

    4  Pages

  36. SB & SBA

    8  Pages

  37. HOME AND GARDEN

    52  Pages

  38. Multilift

    21  Pages

  39. KPL and KWM

    3  Pages

  40. Grundfos GO

    3  Pages

  41. DW

    12  Pages

  42. DIP

    16  Pages

  43. NEW ALPHA2

    7  Pages

  44. GRUNDFOS DWK

    3  Pages

  45. GRUNDFOS DP

    5  Pages

  46. DME, DMS, DDI

    14  Pages

  47. Diffuser

    3  Pages

  48. CUE E-SOLUTIONS

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.