GRUNDFOS DATA BOOKLET Selcoperm SES Electrolysis system Reliable and easy generation of hypochlorite solution for disinfection applications

Open the catalog to page 1
Selcoperm SES - 2

Drinking water treatment Swimming pool water treatment General information Fundamentals of disinfection Disinfection with chlorine The Selcoperm electrolysis principle Benefits of the electrolysis with Selcoperm Applications Requirements for the installation Installation scheme Structure of a Selcoperm system Unique selling points Selcoperm selection diagram Electrolysis cell and hydrogen degassing column Hydraulic chamber Control system Ventilation Constructional scheme Selcoperm components Technical data Brine tank Product storage tank with collecting tray Large product storage tank...

Open the catalog to page 2
Selcoperm SES - 3

Disinfection with chlorine The most widespread disinfectant used in the treatment of drinking water is chlorine, which can be applied in a variety of ways. History has taught us that, in bacteriological terms, chlorinating water is a quite safe way of disinfecting drinking water. After all, more than 75 years have passed since chlorine was used to disinfect drinking water for the first time. Many years of experience have shown that acute toxicity can be excluded, when chlorination is executed correctly. The disinfecting properties of chlorine are based on the fact that hypochlorous acid...

Open the catalog to page 3
Selcoperm SES - 4

General information After dosing the solution into the water flow, no pH value correction is necessary, as it is often required e.g. in electrolysis according to the membrane principle. The sodium hypochlorite solution reacts in a balance reaction, resulting in hypochlorous acid, the efficient disinfectant: NaClO + H2O ↔ NaOH + HClO The dosing quantity depends on the application as well as the local regulations. In general, the concentration after the injection unit is 0.3 to 2 ppm chlorine equivalent. Benefits of the electrolysis with Selcoperm • Robust turn-key system • Safe and reliable...

Open the catalog to page 4
Selcoperm SES - 5

General information Installation scheme Room installation with a Selcoperm system The internal vent tube has to be piped to the exterior of the building. Minimum tube diameter 90 mm. Maximum length of the tubing 10 m. Must be installed without dips and adequately supported to a safe discharge point. Minimum diameter 32 mm for tubing between the unit and the product tank. Tubing from the Tee above the product tank in an upward direction until the Venturi Tee. Brine tank Product tank Dosing pumps Vent tubing Around the electrolysing system, enough space should be left free for operation and...

Open the catalog to page 5
Selcoperm SES - 6

Unique selling points Selcoperm units consist of the electrolysis cell, degassing column, brine dosing pump, exhaust fan with quantitative air flow monitor for air dilution of electrolysis chamber and a water softening system. In addition the following equipment is required: a salt saturator, product tank for storage of the generated solution and dosing pumps. The installation can be rounded off with a measuring and control unit for chlorine dosing, if required. The Selcoperm system is supplied as a turn-key solution, only the tubing for the water connection, the connections for the salt...

Open the catalog to page 6
Selcoperm SES - 7

2. Identification Type key Example: SES-250-M/G-GB Example

Open the catalog to page 7
Selcoperm SES - 8

3. Applications Drinking water treatment Scheme: Drinking water treatment with Selcoperm Groundwater Measuring system Selcoperm electrolytic chlorination system Chemical tank Oxidation Filtration Chemical conditioning

Open the catalog to page 8
Selcoperm SES - 9

Swimming pool water treatment Scheme: Swimming pool water treatment with Selcoperm Swimming pool Remote maintenance, logging per PC DIP compact measuring and control system DIT analysing system Selcoperm electrolytic chlorination system Dosing station for flocculent (PAC) Dosing station for hypochlorite Dosing station for pH-correction Injection units Surge basin Filter Circulation pump Sample water feeding line Sample water recycling line

Open the catalog to page 9
Selcoperm SES - 10

4. Construction Electrolysis cell and hydrogen degassing column • Installed in a separate chamber with a quantitatively monitored air flow. • Electrolysis cell (1) in a vertical transparent PVC pipe for easy process monitoring and visual electrode check. • Electrodes are made of titanium carrier material with a very durable catalytic metallic oxide coating, also suitable for cold water applications of 5 °C and higher. • The hydrogen degassing column (2) removes the formed hydrogen via the vent hole and prevents it from penetrating the product storage tank. The hydrogen is piped through the...

Open the catalog to page 10
Selcoperm SES - 11

Constructional scheme Selcoperm components I Constructional scheme Selcoperm - back side and right side Electrolysis cell Hydrogen degassing column Brine dosing pump Flowmeter Water flow adjustment valve Pressure reducing valve Water softener Level sensor (hydrogen degassing column) Non-return valve Control panel Display Air dilution fan Airflow sensor Inlet water supply Outlet soft water Inlet brine backflush for water softener Inlet brine for dosing pump Outlet regeneration water Outlet product solution Soft water sample valve Brine sample valve Product sample valve Outlet hydrogen gas

Open the catalog to page 11
Selcoperm SES - 12

Constructional scheme Selcoperm - front side and left side Electrolysis cell Hydrogen degassing column Brine dosing pump Flowmeter Water flow adjustment valve Pressure reducing valve Water softener Level sensor (hydrogen degassing column) Non-return valve Control panel Display Air dilution fan Airflow sensor Inlet water supply Outlet soft water Inlet brine backflush for water softener Inlet brine for dosing pump Outlet regeneration water Outlet product solution Soft water sample valve Brine sample valve Product sample valve Outlet hydrogen gas

Open the catalog to page 12
Selcoperm SES - 13

Product number Technical data

Open the catalog to page 13
Selcoperm SES - 14

Technical data Product number Connections Type Selcoperm Outlet soft water Inlet brine water softener Inlet brine dosing pump Outlet regeneration water Outlet product solution SES-125 (mm) SES-125 (inch) SES-250 (mm) SES-250 (inch) SES-500 (mm) SES-500 (inch) SES-1000 (mm) SES-1000 (inch) SES-2000 (mm) SES-2000 (inch)

Open the catalog to page 14
Selcoperm SES - 15

Dimensions, Selcoperm

Open the catalog to page 15
Selcoperm SES - 16

7. Accessories Brine tank For the production of a saturated salt solution. • Material: Polyethylene • With water inlet valve • With gravel bed Weight (tank + gravel) [kg] Product number Outlets [mm] 2 2 2 2 Product storage tank with collecting tray For storage of the hypochlorite solution. • Tank material: Polyethylene • Collecting tray material: Polypropylene • Integrated float switch • Connection box for easy connection with Selcoperm. Collecting tray Product number Large product storage tank without collecting tray For storage of the hypochlorite solution. • Material: Polyethylene • With...

Open the catalog to page 16

All GRUNDFOS catalogs and technical brochures

  1. A WIDE RANGE

    60 Pages

  2. ALPHA1 L

    2 Pages

  3. DME

    2 Pages

  4. UPM3

    92 Pages

  5. GRUNDFOS UPM3

    11 Pages

  6. CRN MAGdrive

    2 Pages

  7. GRUNDFOS CRE

    2 Pages

  8. TPE3

    7 Pages

  9. CIM/CIU

    3 Pages

  10. BMS

    5 Pages

  11. BM

    2 Pages

  12. BACMON

    16 Pages

  13. AQtap

    7 Pages

  14. ALPHA2 L OEM

    19 Pages

  15. A WIDE RANGE

    60 Pages

  16. CRE GRUNDFOS

    2 Pages

  17. MTA

    3 Pages

  18. Unilift CC

    2 Pages

  19. ALPHA1

    2 Pages

  20. AMD-AMG-AFG

    3 Pages

  21. HS

    5 Pages

  22. SQ

    3 Pages

  23. MAGNA/UPE

    12 Pages

  24. Conex DIS-G

    2 Pages

  25. Conex DIS-C

    2 Pages

  26. Sololift2

    9 Pages

  27. VGA and VGB

    28 Pages

  28. Oxiperm Pro

    8 Pages

  29. DMX

    18 Pages

  30. DMH

    18 Pages

  31. MP 204

    3 Pages

  32. TP/TPE

    5 Pages

  33. SP Product

    7 Pages

  34. S-Tube

    4 Pages

  35. SB & SBA

    8 Pages

  36. Multilift

    21 Pages

  37. KPL and KWM

    3 Pages

  38. Grundfos GO

    3 Pages

  39. DW

    12 Pages

  40. DIP

    16 Pages

  41. NEW ALPHA2

    7 Pages

  42. GRUNDFOS DWK

    3 Pages

  43. GRUNDFOS DP

    5 Pages

  44. DME, DMS, DDI

    14 Pages

  45. Diffuser

    3 Pages

  46. CR monitor

    8 Pages

  47. Control MPC

    4 Pages

  48. CMV

    8 Pages

  49. CIM / CIU

    3 Pages

  50. BMP

    9 Pages

Archived catalogs