Oxiperm Pro
8Pages

{{requestButtons}}

Catalog excerpts

Oxiperm Pro - 1

supreme Water disinfection The Oxiperm Pro offers superior water disinfection technology for all types of water systems. It has the following, unique features: • Destroys both free bacteria and biofilm • ses chlorine dioxide, which is extremely efficient, U but has no effect on the taste and smell of the water • he robust design of the Oxiperm Pro ensures high T operational reliability and low maintenance costs • User-friendly operation • asy installation with no interruption of the E building’s water supply ALL ROUND CHLORINE DIOXIDE SOLUTIONS GRUNDFOS Management A/S Poul Due Jensens Vej 7 DK-8850 Bjerringbro Tel: +45 87 50 14 00

Open the catalog to page 1
Oxiperm Pro - 2

The Grundfos Oxiperm Pro system ensures effective disinfection of water in a series of application areas Legionella control begins here The problem Naturally, the water we drink and shower in has to be clean if we are to stay healthy. Unfortunately, one of the most widespread health hazards in drinking water installations worldwide is connected to exceptionally resistant bacteria – legionella. Legionella exist mainly in hot water systems with a low flow rate, areas of stagnation or badly serviced hot water tanks. A layer of slime in the water pipes called biofilm is the habitat for...

Open the catalog to page 2
Oxiperm Pro - 3

Disinfection facts Tough problem – gentle solution What are legionella bacteria? Legionella bacteria are the primary source of legionnaire’s disease – a potentially fatal disease, particularly for those with a weakened immune system. It is estimated that legionnaire’s disease is responsible for 15-20,000 deaths in Europe every year.∗ Legionella bacteria and the biofilm where they live and feed are highly resistant to most disinfection methods. That makes effective combat against them difficult, and their successful elimination calls for specific and highly specialised solutions....

Open the catalog to page 3
Oxiperm Pro - 4

The chemistry of great benefits Removes both free legionella and biofilm The Oxiperm Pro system uses chlorine dioxide for the disinfection of water. This particular chemical compound presents a number of advantages that cannot be matched by any other disinfection method. Legionella bacteria grow and reproduce in biofilm as does 90% of all bacteria in water systems. Biofilm is a layer of slime that exists in water pipes and especially in hot water tanks. Chlorine dioxide diffuses into the biofilm and destroys it from within, whereas other disinfectants only attack the surface of the film. No...

Open the catalog to page 4
Oxiperm Pro - 5

Typical dosing rates in building applications are between 0,1 and 0,4 g/m³. The required total consumption and maximum flow requirement depends on the building type. There is a big difference in annual water consumption, daily maximum consumption and the peak consumption in a block of flats compared to a five star hotel. If you have no reliable flow measurements in the building, the table below gives you an example of how to calculate peak water flow in various types of buildings in order to select the right Oxiperm Pro. Example of calculation of maximum hourly flow rate in a 200-bed hotel...

Open the catalog to page 5
Oxiperm Pro - 6

Injection points Injection of chlorine dioxide into the water system can be done wherever it is deemed suitable. If a total disinfection is desired, the injection point should be located where the water main enters the building. In most cases, it is sufficient to treat only the hot water system where there is the highest risk of bacteria growth. Le Meridien Bristol – five star hotel in Warsaw HOT WATER HOT WATER, CIRCULATION COLD WATER INJECTION POINT HOT AND COLD WATER MUNICIPAL WATER MAIN INJECTION POINT. HOT WATER ONLY A five star hotel must deliver the very highest level of comfort and...

Open the catalog to page 6
Oxiperm Pro - 7

Water meter Injection point Provides impulse or analogue signal for proportional dosing of chlorine dioxide Dosing point of chlorine dioxide solution in water line Sample water out-take Sample water for measurement of chlorine dioxide residual Main water line Water flow to be treated with chlorine dioxide Sample water re-feed Sample water for chlorine dioxide measurement is re-fed to avoid unnecessary water consumption Supply water out-take Water supply for Oxiperm Pro Chlorine dioxide measurement Measurement module that controls the chlorine dioxide residual in treated water Water pipe /...

Open the catalog to page 7
Oxiperm Pro - 8

OXIPERM PRO technical data Technical data Thinking Buildings Chlorine dioxide generation capacity Adjustment of the preparation capacity m anual by menu-controlled operator prompting, automatic by input signal Protection level electronics, dosing pumps, solenoid valve Required concentration of chemicals Admissible • ambient temperature • operation water temperature • chemicals temperature Admissible operation water pressure Admissible relative air humidity Concentration of the chlorine dioxide product solution system rack fastening sleeves solenoid valve reaction / storage tank internal...

Open the catalog to page 8

All GRUNDFOS catalogs and technical brochures

  1. ALPHA1 L

    2 Pages

  2. DME

    2 Pages

  3. UPM3

    92 Pages

  4. GRUNDFOS UPM3

    11 Pages

  5. CRN MAGdrive

    2 Pages

  6. GRUNDFOS CRE

    2 Pages

  7. TPE3

    7 Pages

  8. CIM/CIU

    3 Pages

  9. BMS

    5 Pages

  10. BM

    2 Pages

  11. BACMON

    16 Pages

  12. AQtap

    7 Pages

  13. ALPHA2 L OEM

    19 Pages

  14. CRE GRUNDFOS

    2 Pages

  15. MTA

    3 Pages

  16. Unilift CC

    2 Pages

  17. ALPHA1

    2 Pages

  18. AMD-AMG-AFG

    3 Pages

  19. HS

    5 Pages

  20. SQ

    3 Pages

  21. MAGNA/UPE

    12 Pages

  22. Selcoperm SES

    20 Pages

  23. Conex DIS-G

    2 Pages

  24. Conex DIS-C

    2 Pages

  25. Sololift2

    9 Pages

  26. VGA and VGB

    28 Pages

  27. DMX

    18 Pages

  28. DMH

    18 Pages

  29. MP 204

    3 Pages

  30. TP/TPE

    5 Pages

  31. SP Product

    7 Pages

  32. S-Tube

    4 Pages

  33. SB & SBA

    8 Pages

  34. Multilift

    21 Pages

  35. KPL and KWM

    3 Pages

  36. Grundfos GO

    3 Pages

  37. DW

    12 Pages

  38. DIP

    16 Pages

  39. NEW ALPHA2

    7 Pages

  40. GRUNDFOS DWK

    3 Pages

  41. GRUNDFOS DP

    5 Pages

  42. DME, DMS, DDI

    14 Pages

  43. Diffuser

    3 Pages

  44. CR monitor

    8 Pages

  45. Control MPC

    4 Pages

  46. CMV

    8 Pages

  47. CIM / CIU

    3 Pages

  48. BMP

    9 Pages

Archived catalogs