Constant Pressure Guaranteed DEMAND GRUNDFOS iSOLUTIONS
Open the catalog to page 1Perfect control for any pumps With a Control MPC you can combine great pumps with the perfect control of the CU 352. This means you not only get high efficiency pumps, but also control that ensures they are operated as optimally as possible. Control MPC 2- 6 pumps in parallel 0.37 – 75 kW* Available as: E: All pumps with integrated frequency converter EC: All pumps connected to CUE F: One pump connected to frequency converter S: All pumps fixed speed pumps *Larger systems available on request Tp/TPE 60Hz: From 0.37 kW to 315 kW - TPE up to 22 kW Capacities of up to more than 1250 m3/h Head up...
Open the catalog to page 2CONSTANT PRESSURE By continuously adapting the speed of the pumps to the flow demand, the required pressure is kept constant despite of fluctuations in flow. This ensures the consumer the highest comfort at any time of the day. Starting and stopping the speed controlled pumps are done in a matter that minimizes pressure surges and protects the piping. The days of water hammer are over. • The CU 352 offers perfect control over your pumps: • Constant pressure • Easy to operate • Monitoring • Communication • Energy Reduction • Optimized application functions The most advanced controller on the market...
Open the catalog to page 3SELECTED FUNCTIONS Proportional Pressure The flow demand in a typical installation is not static. It varies depending of the time of day, time of week ortime of year. Since the friction loss in the pipe system is dependent of the flow demand the required discharge pressure from the booster is not static either. h, = Head Loss due to friction, given f = friction factor (Darcy-Weisbach friction coffecient) discharge pressure to the flow demand the pressure can normally be lowered 18 - 20 hours each day while still delivering the required Money saved on energy since the pumps are operated at a lower...
Open the catalog to page 4Application optimized functions Controller features • Pump start and stop speed • Pump stop attempts • Soft pressure build-up • Perfect cascade control of up to • Stop function • Compensation for start up time • User defined duty • 22 different display languages • Min Time between start / stop • Pump curve data • Flow estimation • Standby pumps • 3 Digital inputs (can be extended) • Forced pump change over • Pumps outside duty range extended) • 2 Digital outputs (can be extended) • Pressure relief • Color screen • Backup battery • Proportional Pressure • CIM-Communication modules • Pilot Pump...
Open the catalog to page 55 Pages
2 Pages
20 Pages
24 Pages
21 Pages
3 Pages
59 Pages
3 Pages
5 Pages
2 Pages
2 Pages
2 Pages
92 Pages
11 Pages
28 Pages
9 Pages
3 Pages
10 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
21 Pages
7 Pages
5 Pages
3 Pages
5 Pages
2 Pages
16 Pages
7 Pages
19 Pages
2 Pages
2 Pages
3 Pages
2 Pages
3 Pages
2 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
16 Pages
12 Pages
2 Pages
2 Pages
2 Pages
5 Pages
3 Pages
47 Pages
12 Pages
5 Pages
20 Pages
2 Pages
2 Pages
2 Pages
9 Pages
28 Pages
8 Pages
18 Pages
18 Pages
3 Pages
5 Pages
5 Pages
7 Pages
2 Pages
8 Pages
4 Pages
8 Pages
52 Pages
5 Pages
21 Pages
3 Pages
7 Pages
3 Pages
3 Pages
3 Pages
12 Pages
16 Pages
2 Pages
16 Pages
2 Pages
3 Pages
7 Pages
7 Pages
7 Pages
3 Pages
7 Pages
10 Pages
3 Pages
3 Pages
5 Pages
16 Pages
14 Pages
3 Pages
12 Pages
20 Pages
60 Pages
8 Pages
3 Pages
4 Pages
8 Pages
52 Pages
9 Pages
52 Pages
60 Pages
15 Pages
32 Pages