Overview: The document outlines the GENO-therm® product series by Grünbeck, which is designed to protect heating systems using fully demineralised water. This method prevents scaling and corrosion, ensuring efficient and durable operation.
Specifications: GENO-therm® includes reusable and disposable cartridges, filling devices, and cases. The filling devices are available in Premium, Komfort, and Basic versions, featuring conductivity measuring cells and water meters. Cartridges are available for full demineralisation, with both reusable and disposable options.
Procedures: The process involves using GENO-therm® devices to fill heating systems with demineralised water, monitoring conductivity for optimal performance. GENO®-safe A may be used if pH levels are not ideal.
Standards and Recommendations: The use of fully demineralised water is recommended by VdTÜV and complies with VDI standard 2035 and other German industry standards, providing legal certainty and meeting requirements to prevent scaling and corrosion.
Advantages: Benefits include improved efficiency, reduced noise, extended service life, and lower operational costs. The system is user-friendly, requiring no complex calculations based on boiler capacity or system volume.
Technical Details: Detailed specifications for GENO-therm® filling devices and cartridges are provided, including connection diameters, flow rates, and operating pressures, along with descriptions of product components and features.
Conclusion: GENO-therm® offers a comprehensive solution for heating system protection, emphasizing ease of use, cost-effectiveness, and compliance with industry standards. Demineralised water ensures long-term protection against scaling and rust, maintaining heating system efficiency.
Mobile Reverse Osmosis Systems:
  • AVRO-flex 50: Designed for direct filling with low-salt water, featuring a 3/4" connection, 50 l/h permeate capacity at 15°C, and a 0.7 kW load. It is compact, requires no pre-treatment, and includes a 5 µm filter and pressure booster pump.
  • AVRO-flex 250: Similar to AVRO-flex 50, handling feed water with up to 500 ppm salt concentration and over 95% salt rejection, operating on 230 V, 50 Hz.
GENO-therm® Accessories: Includes dosing units, manual pumps, water test kits, measuring devices, and various adapters and valves to support heating system operation and maintenance.
GENO®-safe A: A corrosion inhibitor and hardness stabilizer for systems with steel, copper, and aluminum, preventing scale and ensuring a corrosion-inhibiting layer. Dosage varies for new and existing systems, with molybdenum concentration monitoring recommended.
GENO-therm® Analysis Case: Used to determine heating water parameters like pH and conductivity, including calibration solutions and test kits for hardness and molybdenum concentration, essential for system efficiency.
Water Softeners: Offered as an alternative to low-salt operation, compatible with GENO-therm® devices, including WINNI-mat VGX 14-H, HEH 9, and MEH models.
Certifications: The company is certified by TÜV SÜD according to DIN EN ISO 9001, DIN EN ISO 14001, DIN EN ISO 13485, and SCC** standards.
See more

Catalog excerpts

Product series for the protection of heating systems - GENO-therm-1

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 11:10 Uhr Seite 1 Product series for the protection of heating systems GENO-therm® Heating protection has never been so easy GENO-therm® case Premium Reusable cartridge Filling device Premium ty gal certain Absolute le tion asy applica G Extra-e g and rust from scalin tion G Protec G www.gruenbeck.com

 Open the catalog to page 1
Product series for the protection of heating systems - GENO-therm-2

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:23 Uhr Seite 2 GENO-therm®: Nothing could be easier GENO-therm®: Nothing could be easier Deposits on heat exchangers may reduce the efficiency As little as 1 mm of scale deposits already increases the energy consumption by approx. 10 %. The application of GENO-therm® is very easy as all components are harmonised with each other.

 Open the catalog to page 2
Product series for the protection of heating systems - GENO-therm-3

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:23 Uhr Seite 3 Water is energy Water is energy use it with care Varying technical rules and regulations have made a mystery of the topic „heating water treatment“ and the considerable demands, the boiler manufacturers are putting on the executing craftsmen represent an additional challenge. Modern materials, complex components and a compact design with small pipe cross-sections extremely increase the demands on the filling water. Heating systems – no matter whether oil, gas or pellets – can only work effectively if their efficiency...

 Open the catalog to page 3
Product series for the protection of heating systems - GENO-therm-4

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 4 11.04.2012 9:24 Uhr Seite 4 Demineralised water offers ideal protection Demineralised water offers ideal protection GENO-therm® consistently focuses on fully demineralised water (demi water/low-salt operation). All the requirements of the VDI standard 035, sheets 1 and , as well as the joint worksheet by the BDH and the ZVSHK are met. Fully demineralised water ensures the protection from scale and corrosion. Absolute legal certainty With demineralised water, the craftsman can virtually count on legal certainty. The heating protection...

 Open the catalog to page 4
Product series for the protection of heating systems - GENO-therm-5

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:24 Uhr Seite 5 Demineralised water offers ideal protection GENO-therm® filling device Premium Installation example 1 6 2 4 3 5 Installation example of a heating system 1 To the residential pipe system 3 Fine filter BOXER® KD 2 Residential water meter 4 GENO-therm® filling device 5 Reusable cartridge 6 Boiler 5

 Open the catalog to page 5
Product series for the protection of heating systems - GENO-therm-6

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 6 11.04.2012 9:24 Uhr Seite 6 GENO-therm® filling devices GENO-therm® filling devices Three versions for each and every need GENO-therm® conductivity measuring cell Water meter GENO-therm® filling device Komfort Filling of heating systems by means of GENO-therm® filling devices All types of GENO-therm® filling devices can be used in order to fill the heating system according to the applicable standards (e. g. DIN EN 1717, DIN 14868). In order to do so, it would be ideal to connect a disposable GENO-therm® cartridge or a reusable GENO-therm®...

 Open the catalog to page 6
Product series for the protection of heating systems - GENO-therm-7

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:24 Uhr Seite 7 GENO-therm® filling devices Pressure reducer Water meter (analogue/digital) Deaeration valves GENO-therm® conductivity measuring cell System separator Shut-off valve Shut-off valve Water meter screw connection Water meter screw connection Bottle adapter Rigid foam insulation GENO-therm® filling device Basic GENO-therm® filling device Komfort GENO-therm® filling device Premium The GENO-therm® filling device Basic features the following components: G System separator acc. to DIN EN 1717 G Dirt trap G Adjustable...

 Open the catalog to page 7
Product series for the protection of heating systems - GENO-therm-8

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 8 11.04.2012 9:25 Uhr Seite 8 Disposable and reusable GENO-therm® cartridges for full demineralisation Disposable and reusable GENO-therm® cartridges for full demineralisation Reusable GENO-therm® cartridges The reusable cartridge is designed for the full demineralisation of heating water and is supplied with mixed-bed resin. In order to connect the reusable cartridge to the pipe, we recommend using the GENO-therm® hose set. The reusable cartridge features an integrated non-return valve and a flow stabiliser which makes it impossible to...

 Open the catalog to page 8
Product series for the protection of heating systems - GENO-therm-9

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:25 Uhr Seite 9 Disposable and reusable GENO-therm® cartridges for full demineralisation Disposable GENO-therm® cartridge 110 Sample calculation G G G Conductivity of the filling water: 500 μS/cm Cartridge used: disposable GENO-therm® cartridge 110 110/500 = 0. m³ (equals 0 litres) Result: At the current conductivity, 0 litres of water may be fully demineralised by this type of disposable cartridge. Disposable GENO-therm® cartridge 110 without adapter Disposable GENO-therm® cartridge 110 with adapter (including cardboard box...

 Open the catalog to page 9
Product series for the protection of heating systems - GENO-therm-10

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 10 11.04.2012 9:25 Uhr Seite 10 GENO-therm® cases GENO-therm® cases – safe, easy and proven in practice GENO-therm® case Premium with GENO®-Multi LF The new GENO-therm® cases have been thoroughly tried and tested and perfectly fit into the Sortimo in-vehicle equipment. They are, of course, compatible with all other GENO-therm® products. The GENO-therm® case Premium, combined with the disposable and reusable cartridges offers highest convenience when it comes to the filling of a heating system. The case features: G Conductivity meter GENO®-Multi...

 Open the catalog to page 10
Product series for the protection of heating systems - GENO-therm-11

0185_GENO-therm_gb_2012-04-11.qxd:4405_0165_GENO-therm_BE 11.04.2012 9:26 Uhr Seite 11 GENO-therm® cases GENO-therm® case Basic GENO-therm® service case GENO-therm® case Basic GENO-therm® conductivity measuring cell GENO-therm® service case The Basic case features: G GENO-therm® hose set G Analogue water meter G GENO-therm® conductivity measuring cell G Twin screw connections to connect the water meter G Two twin nipples to connect the disposable GENO-therm® cartridge and the GENO-therm® conductivity measuring cell with adapter This equipment, together with the disposable and reusable GENO-therm®...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.