GENO®-Ultrafil

GENO®-Ultrafil

GENO®-Ultrafil

Product catalog summary
Overview: The GENO®-Ultrafil 450 and 900 are ultrafiltration systems designed to reduce microbiological loads in drinking water, particularly for private water supply systems. They effectively filter germs, bacteria, viruses, parasites, and turbid substances.
Functioning: The system uses capillary membranes with a cut-off of less than 0.01 µm. Raw water is pre-filtered and directed through the membrane, retaining microorganisms and particles. The GENO®-Ultrafil 450 uses direct rinsing with raw water, while the 900 model uses backwashing with filtrate before rinsing.
Applications: Suitable for treating city water, well and spring water, and water from treatment systems that are not immediately consumable due to microbiological loads.
Requirements: Requires a raw water pressure of 2.5 to 5 bar and pre-filtration with a filter fineness of less than 100 µm. Installation must be in a clean, dry, frost-proof location with a drain connection.
Scope of Delivery: Includes a microprocessor controller, ultrafiltration membrane, manometer, flow sensor, sampling valves, solenoid valves, and pressure switch. The system is mounted on an anodized aluminum rack.
Optional Accessories: Accessories include a filtrate tank, fitting set, and pressure booster to optimize system efficiency and maintain constant pressure during operation.
Technical Specifications: The GENO®-Ultrafil 450 has a nominal filtrate capacity of 450 l/h, while the 900 model has 900 l/h. Both systems require a power supply of 230 V/50 Hz and have specific dimensions and weights.
Installation Instructions: Systems are designed for wall mounting. Installation must comply with local directives, and a fine filter should be installed upstream. A system separator is required if connected to the public water supply.
See more

Catalog excerpts

GENO®-Ultrafil-1

grUnbeek *#WASSERAUFBEREITUNG UltrafiltrationProduct Data Sheet H 510Ultrafiltration Systems GENO®-Ultrafil 450/900 Application The ultrafiltration system GENO®-Ultrafil is designed for the reduction of microbiological loads (germs, bacteria, viruses, parasites) and turbid substances contained in the drinking water, in particular when installed in private water supply systems. Functioning The membrane filter of the ultrafiltration system GENO®-Ultrafil consists of a multitude of capillary membranes with a cut-off of less than 0,01 |jm. The endings of these capillary membranes are firmly sealed in a pressure pipe, thus ensuring a safe separation of the sector containing loaded raw water from the sector containing pure water. Functioning: The raw water which was pre-filtered by means of a fine filter (e. g. BOXER® RD) is directed to the raw water side of the membrane filter from the bottom and then flowing from the inside out through the membrane element. Micro-organisms and particles will be retained on the surface of the membrane. The filtrate accumulates in the upper part of the membrane filter and is available for consumption. After a freely-programmable time which depends on the load of the raw water, the membrane filter will be rinsed automatically for a short time, thus washing the filtered particles from the filter. The rinsing of the GENO®-Ultrafil 450 is effected by direct rinsing of the membrane by means of raw water. Fig. 1: GENO®-Ultrafil 450 In case of the GENO®-Ultrafil 900 system, the membranes are backwashed by means of filtrate prior to the rinsing by means of raw water. One membrane produces the filtrate required for the backwash of the other membrane. Afterwards, the filtration cycle is started again in both systems. During the rinsing, no filtrate is available for consumption. Areas of application The GENO®-Ultrafil 450 and 900 systems are solely suitable for the treatment of drinking water which cannot be used for consumption immediately due to its micro-biological load. • City water (drinking water according to the German Drinking Water Ordinance TrinkwV 2001) • Drinking water from wells and springs • Drinking water from treatment systems. Requirements A raw water pressure of at least 2.5 and max. 5 bar is required for the operation of a GENO®-Ultrafil ultrafiltration system. The raw water must be filtered by a prefilter with a filter fineness of less than 100 jm. The installation site must be clean, dry and frost-proof and it must provide a sufficiently dimensioned drain connection near the GENO®-Ultrafil system. As no water originating from a small system may enter the public drinking water supply, the public supply into a small system is only admissible if a free outlet according to DIN EN 1717 is available. Scope of delivery Basic equipment Microprocessor controller with LCD display to indicate the function and the maintenance interval by means of a voltage-free collective fault signal, ultrafiltration membrane with recommendation by the DVGW-KTW, manometer on the raw water and filtrate side, flow sensor, flame-sterilizable sampling valves on raw water and filtrate side, solenoid valves, pressure switch to protect the system from overpressure. High-quality system rack made of anodized aluminium for wall mounting by others on site. Installation and operation manual. GENO®-Ultrafil 450 Order no. 561 200 GENO®-Ultrafil 900 Order no. 561 230 Edition: Supersedes edition: We reserve the right to modifications! edited by: KONP/gfried-ko • g:\ PDB-H510-GB-ULTRAFIL.DOC

 Open the catalog to page 1
GENO®-Ultrafil-2

grUnbeek *#WASSERAUFBEREITUNG UltrafiltrationProduct Data Sheet H 510 Optional accessories In order to ensure the smoothest operation of the filter system possible and to optimise the efficiency of the backwash, the ultrafiltration systems GENO®-Ultrafil 450 and 900 may be equipped with optional accessories. These consist of a filtrate tank, a fitting set for connection to the GENO®-Ultrafil system as well as a pressure booster. Using the additional equipment will result in the following advantages for the system operation : • no reduction in the filtrate flow during rinsing • constant pressure...

 Open the catalog to page 2
GENO®-Ultrafil-3

grUnbeek *#WASSERAUFBEREITUNG UltrafiltrationProduct Data Sheet H 510 Technical specifications * The performance data depend on the raw water composition resp. the operating method ** If the Ultrafil systems are to be operated according to E-DIN 2001, the treatment volume must be limited to 0,5 m3/h In the filtrate and feed pipe provided by others on site, a feature to separate the pipes must be available (e. g. screw connections). Edition: Supersedes edition: We reserve the right to modifications! edited by: KONP/gfried-ko • g:\ PDB-H510-GB-ULTRAFIL.DOC

 Open the catalog to page 3
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.