Overview: The document outlines SANERGRID's containment solutions and extinguishing systems for transformers, focusing on retention tanks and extinguishing covers designed to prevent ground contamination and reduce fire risks.
Retention Tanks:
  • BDR-P, BDR-GC, BDRSA: These are retention tanks with removable walls, available in painted or galvanized finishes for indoor and outdoor use. They ensure full dielectric retention and include earth connection points.
  • TRFLEX®-REFOR & -ECO: Flexible retention tanks for temporary storage, featuring high resistance tarpaulin and quick setup. They are suitable for outdoor use with capacities ranging from 250 to 80,000 liters.
  • TRT® and TRT-MODULO™: Outdoor retention tanks designed for power transformers, featuring hot dip galvanization, emergency siphon by-pass, and modular configurations for higher capacities.
Extinguishing Systems:
  • ERT® and ERT® MODULO™: Monobloc and modular extinguishing retention tanks for transformers, validated by CNPP. They offer total dielectric containment and are equipped with fire extinguishing covers.
  • EXTICOV™: Frame-based extinguishing cover for concrete pits in substations, featuring quick installation and integration with filtration systems for rainwater drainage.
Rainwater Drainage Filters:
  • PETRO-PIT®, PETRO PIPE®, PETRO BARRIER®: These systems provide continuous rainwater evacuation, filtration of hydrocarbons, and complete sealing in case of oil spills. They are recognized by major industries in the UK and Europe.
Company Profile: SANERGRID specializes in industrial risk management solutions, particularly for electrical transformers. Their products comply with UK and European environmental standards and have been successfully tested by the CNPP.
See more

Catalog excerpts

Retention tanks and fire extinguishing bunds-1

Containment solutions and extinguishing systems for transformer

 Open the catalog to page 1
Retention tanks and fire extinguishing bunds-2

Retention tanks with removable walls BDR-P, BDR-GC and BDRSA: 3 ranges regarding your need 2 removable walls tank (1 lengthwise, 1 widthwise): - BDR-P: painted RAL 7033 – indoor use - BDR-GC: hot dip galvanized -outdoor use - Metal thickness 20 up to 30/10 - Closing system by screws and nuts 4 removable walls retention tank: - BDRSA: galvanised still - indoor use – clamping system For all retention tanks: - Full retention of the dielectric ensured - Special technical silicone joint delivered with material to ensure proper sealing of the tank - Earth connection points Flexible retention tanks...

 Open the catalog to page 2
Retention tanks and fire extinguishing bunds-3

Monobloc extinguishing retention tanks ERT® For distribution transformers, auxiliary & autotransformer Self-load bearing hot dip galvanised retention tanks equipped with an extinguishing cover. Validated by CNPP, independent French national laboratory under EDF technical specifications Adjustable beams to support the transformer Total dielectric containment (EU - 100% / UK - 120%), Dimensions and configurations adapted to every need Hot dip galvanised gratings 30 x 30 (option) Drain vale 1,5 or 2 inches regarding model Stainless still tapings and valve, emergency siphon by-pass Outdoor use: filtration...

 Open the catalog to page 3
Retention tanks and fire extinguishing bunds-4

Special tanks and extinguishing frames Taylor made extinguishing retention tanks: dimensions, configurations, retention volumes regarding any of your need Special extinguishing frames assembled on prefabricated concrete retention tanks or small pit etc.… Rainwater drainage filters and accessories PETRO-PIT® - PETRO PIPE® -PETRO BARRIER® and special systems Rainwater filter cartridges SPI® fulfilling the 3 following functions: - Continuous rainwater evacuation - Hydrocarbons traces filtration, when oil sheen is present in water (hydrocarbons rate in output of the filter below 5 ppm) - Complete...

 Open the catalog to page 4