Overview: The document presents MIDSUN®'s solutions for mitigating animal interference in electrical stations, highlighting the importance of biodiversity protection and preventing electrical faults caused by wildlife. The solutions are user-friendly, durable, and environmentally friendly, requiring no glue or heat for application.
Key Features of MIDSUN® Technology:
  • Resistance to UV, arc, and ozone.
  • High dielectric strength and thermal endurance.
  • Good formability and chemical resistance.
  • Increased creepage distance and easy implementation.
Product Ranges:
  • E/TAPE Range: Self-fusing insulation tapes for high-voltage cables, offering phase-to-ground insulation up to 75 kV.
  • E/FOURREAU Range: Silicone sleeves for cables and guy wires, providing insulation up to 35 kV and wildlife protection.
  • E/PLAQUE Range: Insulating sheets for custom covers, suitable for equipment up to 35 kV.
Installation Instructions:
  • Ensure surfaces are clean before application.
  • Wrap tapes with a 2/3 overlap and apply in opposite directions for multi-layer insulation.
  • Sleeves are slit for easy application without cutting connections.
Technical Specifications:
  • Products are made from high-quality silicone, offering excellent electrical and mechanical properties.
  • Designed to withstand harsh outdoor conditions and provide long-term protection.
Warranty and Lifespan: Products have a shelf life of 5 years and are guaranteed for a minimum of 10 years when applied according to recommendations.
Specifications: The document details specifications for SANERGRID® products, including phase-to-ground insulation of 35 kV, elongation at break of 300%, durometer of 65 ± 10 shore A, tensile strength of 600%, and chemical resistance. Products are self-extinguishing within 15 seconds and meet flammability standards.
Dimensions: The E/PLAQUE range is custom-molded and available in various sizes. The E/COVER range offers over 1500 references with varying dimensions.
Installation Instructions: For E/PLAQUE, installation involves placing the cover, cutting to size, punching holes, and securing with PUSH PINS. E/COVER installation involves placing the cover, inserting fastening clips, and ensuring no contact between phases and ground. E/BARRIER products are designed for easy installation using a hot stick.
Tests and Standards: Products have been tested for partial discharge, erosion resistance, UV stability, thermal endurance, ultimate elongation, and dielectric strength, maintaining flexibility and insulation value under various conditions.
Product Descriptions: The E/COVER silicone cover prevents outages caused by birds and has a lifespan of over 30 years. The E/BARRIER range prevents wildlife from encountering live parts and is made from durable, fire-resistant material. E/PEINTISO is a silicone insulating paint offering high dielectric strength and weather protection.
Applications: Products protect electrical equipment from wildlife, prevent power system failures, and provide insulation, applicable in substations, distribution equipment, and various electrical installations.
Lifespan and Warranty: The E/COVER range has a shelf life of 5 years, while E/PEINTISO has a shelf life of 6 months. Both are guaranteed for a minimum of 10 years when applied according to recommendations.
Technical Specifications: For E/PEINTISO, non-vulcanized phase characteristics include a specific gravity of 1.39 N/m3 and a curing time of 24 hours. Vulcanized phase characteristics include a durometer hardness of 28 points and a dielectric strength of 152 kV/cm.
Specifications: - Dielectric Constant (ASTM D150): 4.0 from 100Hz to 100Hz - Thermal Conductivity: 0.5 W/mK - Standard conditions: 23°C and 50% relative humidity.
Dimensions and Ordering: - Available in 1 US gallon (approximately 3.78 L) and 5 US gallons (approximately 19 L). - Limited stock; orders typically require a lead time of 4 to 6 weeks. Urgent delivery available for an additional fee.
Application Instructions: - E/PEINTISO paint is applied in a single coat on metallic surfaces. - Ensure adequate ventilation during extensive use. - Uncured product may cause eye irritation; rinse eyes thoroughly with water and seek medical attention if contact occurs.
Additional Solutions: - HVIC Range: Self-cleaning hydrophobic silicone paint for high-voltage electrical insulators. - SILPROCOAT Range: Anti-corrosion paint for encapsulating lead paint in electrical substations.
Contact Information: - SANERGRID® Group Headquarters: 19 Boulevard Eugène Deruelle, 69003 Lyon, France. - Sales Offices: 10 Newbridge Industrial Est Athgarvan Road, W12 KW81 Newbridge, Ireland. - Website: www.sanergrid.com, www.technikelec.com - Phone: +33 9 77 19 58 84 - Email: [email protected]
See more

Catalog excerpts

CATALOGUE ANIMAL MITIGATION MIDSUN-1

ANIMAL MITIGATION WITHOUT GLUE OR HEAT

 Open the catalog to page 1
CATALOGUE ANIMAL MITIGATION MIDSUN-2

REVOLUTIONARY BIRD PROTECTION WITHOUT GLUE OR HEAT SHRINK Respecting Biodiversity in Electrical Stations Since the 1980s, MIDSUN® has been the world leader in 4th generation silicone solutions for electrical energy. Our proven technology is easy to use, removable, ultra-durable, plastic-free, and resistant to UV and temperature variations. With the proliferation of power lines, the development of renewable energy in rural areas, and the automation in electrical substations, electrical faults caused by external factors are on the rise. Protecting biodiversity from the hazardous effects of electricity...

 Open the catalog to page 2
CATALOGUE ANIMAL MITIGATION MIDSUN-3

SELF-FUSING AND SELF-AMALGAMATING INSULATION TAPES E/TAPE Range PRODUCT DESCRIPTION The E/TAPE range comprises numerous references of highly arc-resistant insulation tapes that provide phase-to-ground electrical insulation. Made of self-fusing inorganic silicone rubber, each tape is wound on an easy-to-separate and tear film. Their application requires neither glue nor heating and can adapt to any type of connector, busbar, or cable up to: Thickness 0.76 mm: from 15 kV to 35 kV (1 layer 15 kV, 3 layers 35 kV) Thickness 2.03 mm: from 35 kV to 75 kV (1 layer 35 kV, 3 layers 75 kV) Always wrap the...

 Open the catalog to page 3
CATALOGUE ANIMAL MITIGATION MIDSUN-4

INSTALLATION INSTRUCTIONS Ensure that the tape and the device are clean. Remove dust, dirt, and moisture from your hands; otherwise, the tape may not adhere properly. 1. 2. 3. 4. 5. 6. 7. Peel off the backing layer. At the start of the application, wrap the tape 100% over itself1. When applying the E/TAPE, stretch the tape by 10% and make a 2/3 overlap. The first wrap will provide phase-to-ground insulation of 15 kV (thickness 0.76 mm) or 35 kV (thickness 2.03 mm). A second wrap applied in the opposite direction, in the same manner as before, will provide insulation of 35 kV (thickness 0.76 mm)...

 Open the catalog to page 4
CATALOGUE ANIMAL MITIGATION MIDSUN-5

INSULATION SLEEVES FOR CABLES AND GUY WIRES E/FOURREAU Range PRODUCT DESCRIPTION The E/FOURREAU range consists of silicone sleeves used to protect a variety of distribution and substation equipment up to 35 kV phase-to-ground. This flexible silicone rubber sleeve provides high-quality electrical insulation for overhead distribution lines, cables, and substation busbars. The E/FOURREAU sleeve is made from insulating silicone material suitable for harsh outdoor conditions in electrical substations. The E/FOURREAU range is used to provide an additional layer of electrical insulation to protect animals...

 Open the catalog to page 5
CATALOGUE ANIMAL MITIGATION MIDSUN-6

* Packaging subject to possible changes based on factory production. INSTALLATION INSTRUCTIONS The E/FOURREAU sleeve is designed with a slit for easy application without the need to cut electrical connections. The sleeve is simply opened and stretched, allowing it to quickly slide over the cable or busbar to be protected. No heat shrink is required for its application. No tools other than a cutting tool to obtain the appropriate length are required. The E/FOURREAU range is flexible and adjustable, making it easy to apply and remove. Here are the steps to follow: Open the E/FOURREAU sleeve and...

 Open the catalog to page 6
CATALOGUE ANIMAL MITIGATION MIDSUN-7

CUT-TO-SIZE INSULATING SHEETS E/PLAQUE Range PRODUCT DESCRIPTION The E/PLAQUE range consists of high-temperature vulcanized silicone sheets reinforced with polyester fabric. They are ready to be cut to size on site to create custom covers when the geometry of the parts to be protected does not allow the use of standard covers. Manufactured from 65-durometer silicone with a thickness of 3.175 mm, the E/PLAQUE range is delivered in rolls. It provides protection for phase-to-phase and phase-to-ground components on equipment installed in substations and distribution stations up to 35 kV. APPLICATIONS...

 Open the catalog to page 7
CATALOGUE ANIMAL MITIGATION MIDSUN-8

INSTALLATION INSTRUCTIONS The E/PLAQUE range is designed for easy application without the need to undo electrical connections. E/PLAQUE products are flexible and adjustable, allowing for easy, reusable installation and removal without leaving any heat or glue residues on the protected parts. 1. 2. 3. Place the cover on the device to the desired dimensions and cut with scissors as needed. Punch holes using the AVI-PLAQ-HolePince hole punch at the desired locations for the PUSH PINS clips and secure the cover by attaching the accessories in all the holes of the cover. Cover the device in a way...

 Open the catalog to page 8
CATALOGUE ANIMAL MITIGATION MIDSUN-9

PREFORMED STANDARD PROTECTIVE COVERS E/COVER Range PRODUCT DESCRIPTION The E/COVER silicone cover is a high-temperature vulcanized silicone cover made from 65durometer silicone, designed to fit bushings and cross-arms. These insulating covers are designed to prevent outages caused by birds on substation and distribution equipment ranging from 15 to 35 kV. The natural hydrophobicity of silicone and its superior UV and chemical resistance properties ensure a projected lifespan of over 30 years. The E/COVER provides an electrical insulation layer to protect birds around substations and distribution...

 Open the catalog to page 9
CATALOGUE ANIMAL MITIGATION MIDSUN-10

All our standard cover ranges come with a reference and associated plans. Example for AVI-COV-BC-LG: AVI-CAGE-L AVI-COV-BC-SMALL OTHER STANDARD AND CUSTOM REFERENCES Please consult us. A range of over 1500 references: Straight connectors Surge arresters Circuit breaker covers Surge limiters And more. INSTALLATION INSTRUCTIONS All covers are secured with removable silicone clips. This mountable and detachable closure system prevents breaking the protective cover, providing great installation flexibility and easy access to the insulator when needed. The E/COVER is designed for quick application,...

 Open the catalog to page 10
CATALOGUE ANIMAL MITIGATION MIDSUN-11

Find our online application guide. This document is property of SANERGRID® Group. Any use, reproduction, transmission, or divulgation of the present document without any previous written agreement by SANERGRID® is strictly forbidden. OTHER TYPES OF E/COVER APPLICATIONS: TESTS AND STANDARDS TEST DESCRIPTION TEST RESULTS Partial Discharge and Erosion Resistance Thermal Endurance Ultimate Elongation Dielectric Strength COMMENTS Most products are between phase and ground, showing leakage currents. Long-term exposure to extreme climates. Maintains a high degree of flexibility. Can withstand long periods...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.