Group: Groupe SANERGRID

Catalog excerpts

ANIMAL MITIGATION WITHOUT GLUE OR HEAT
Open the catalog to page 1
REVOLUTIONARY BIRD PROTECTION WITHOUT GLUE OR HEAT SHRINK Respecting Biodiversity in Electrical Stations Since the 1980s, MIDSUN® has been the world leader in 4th generation silicone solutions for electrical energy. Our proven technology is easy to use, removable, ultra-durable, plastic-free, and resistant to UV and temperature variations. With the proliferation of power lines, the development of renewable energy in rural areas, and the automation in electrical substations, electrical faults caused by external factors are on the rise. Protecting biodiversity from the hazardous effects of...
Open the catalog to page 2
SELF-FUSING AND SELF-AMALGAMATING INSULATION TAPES E/TAPE Range PRODUCT DESCRIPTION The E/TAPE range comprises numerous references of highly arc-resistant insulation tapes that provide phase-to-ground electrical insulation. Made of self-fusing inorganic silicone rubber, each tape is wound on an easy-to-separate and tear film. Their application requires neither glue nor heating and can adapt to any type of connector, busbar, or cable up to: Thickness 0.76 mm: from 15 kV to 35 kV (1 layer 15 kV, 3 layers 35 kV) Thickness 2.03 mm: from 35 kV to 75 kV (1 layer 35 kV, 3 layers 75 kV) Always wrap...
Open the catalog to page 3
INSTALLATION INSTRUCTIONS Ensure that the tape and the device are clean. Remove dust, dirt, and moisture from your hands; otherwise, the tape may not adhere properly. 1. 2. 3. 4. 5. 6. 7. Peel off the backing layer. At the start of the application, wrap the tape 100% over itself1. When applying the E/TAPE, stretch the tape by 10% and make a 2/3 overlap. The first wrap will provide phase-to-ground insulation of 15 kV (thickness 0.76 mm) or 35 kV (thickness 2.03 mm). A second wrap applied in the opposite direction, in the same manner as before, will provide insulation of 35 kV (thickness 0.76...
Open the catalog to page 4
INSULATION SLEEVES FOR CABLES AND GUY WIRES E/FOURREAU Range PRODUCT DESCRIPTION The E/FOURREAU range consists of silicone sleeves used to protect a variety of distribution and substation equipment up to 35 kV phase-to-ground. This flexible silicone rubber sleeve provides high-quality electrical insulation for overhead distribution lines, cables, and substation busbars. The E/FOURREAU sleeve is made from insulating silicone material suitable for harsh outdoor conditions in electrical substations. The E/FOURREAU range is used to provide an additional layer of electrical insulation to protect...
Open the catalog to page 5
* Packaging subject to possible changes based on factory production. INSTALLATION INSTRUCTIONS The E/FOURREAU sleeve is designed with a slit for easy application without the need to cut electrical connections. The sleeve is simply opened and stretched, allowing it to quickly slide over the cable or busbar to be protected. No heat shrink is required for its application. No tools other than a cutting tool to obtain the appropriate length are required. The E/FOURREAU range is flexible and adjustable, making it easy to apply and remove. Here are the steps to follow: Open the E/FOURREAU sleeve...
Open the catalog to page 6
CUT-TO-SIZE INSULATING SHEETS E/PLAQUE Range PRODUCT DESCRIPTION The E/PLAQUE range consists of high-temperature vulcanized silicone sheets reinforced with polyester fabric. They are ready to be cut to size on site to create custom covers when the geometry of the parts to be protected does not allow the use of standard covers. Manufactured from 65-durometer silicone with a thickness of 3.175 mm, the E/PLAQUE range is delivered in rolls. It provides protection for phase-to-phase and phase-to-ground components on equipment installed in substations and distribution stations up to 35 kV....
Open the catalog to page 7
INSTALLATION INSTRUCTIONS The E/PLAQUE range is designed for easy application without the need to undo electrical connections. E/PLAQUE products are flexible and adjustable, allowing for easy, reusable installation and removal without leaving any heat or glue residues on the protected parts. 1. 2. 3. Place the cover on the device to the desired dimensions and cut with scissors as needed. Punch holes using the AVI-PLAQ-HolePince hole punch at the desired locations for the PUSH PINS clips and secure the cover by attaching the accessories in all the holes of the cover. Cover the device in a...
Open the catalog to page 8
PREFORMED STANDARD PROTECTIVE COVERS E/COVER Range PRODUCT DESCRIPTION The E/COVER silicone cover is a high-temperature vulcanized silicone cover made from 65durometer silicone, designed to fit bushings and cross-arms. These insulating covers are designed to prevent outages caused by birds on substation and distribution equipment ranging from 15 to 35 kV. The natural hydrophobicity of silicone and its superior UV and chemical resistance properties ensure a projected lifespan of over 30 years. The E/COVER provides an electrical insulation layer to protect birds around substations and...
Open the catalog to page 9
All our standard cover ranges come with a reference and associated plans. Example for AVI-COV-BC-LG: AVI-CAGE-L AVI-COV-BC-SMALL OTHER STANDARD AND CUSTOM REFERENCES Please consult us. A range of over 1500 references: Straight connectors Surge arresters Circuit breaker covers Surge limiters And more. INSTALLATION INSTRUCTIONS All covers are secured with removable silicone clips. This mountable and detachable closure system prevents breaking the protective cover, providing great installation flexibility and easy access to the insulator when needed. The E/COVER is designed for quick...
Open the catalog to page 10
Find our online application guide. This document is property of SANERGRID® Group. Any use, reproduction, transmission, or divulgation of the present document without any previous written agreement by SANERGRID® is strictly forbidden. OTHER TYPES OF E/COVER APPLICATIONS: TESTS AND STANDARDS TEST DESCRIPTION TEST RESULTS Partial Discharge and Erosion Resistance Thermal Endurance Ultimate Elongation Dielectric Strength COMMENTS Most products are between phase and ground, showing leakage currents. Long-term exposure to extreme climates. Maintains a high degree of flexibility. Can withstand long...