The warranty is valid if the product is used as intended, installed, and maintained by authorized personnel, and operated within specified limits.
Instructions for safe transport and storage to prevent damage.
Specifications and operational limits of the pump model EP-1.
Instructions for configuring control units like BEKA-troniX1 and EP-tronic.
Procedures for initiating and operating the pump system.
Methods for cleaning the pump and components.
Groeneveld-BEKA GmbH, located in Pegnitz, Germany, is the manufacturer of the EP-1 lubrication system.
The EP-1 is an electrically actuated pump for automatic lubrication, suitable for vehicles and machinery, supporting up to three outlets and operating with commercial lubricants up to NLGI-2 at a maximum pressure of 350 bar.
Complies with EU directives, including the Machinery Directive, Low Voltage Directive, and Electromagnetic Compatibility Directive. CE and E1 certified.
Depressurize, switch off power, and disconnect components for safe shutdown and disposal.
Ensure secure transport and store in a cool, dry place.
Features delivery volume per stroke, operates at temperatures between -35°C and +70°C, with a reservoir capacity of 1.9 to 16.0 liters, protected to IP 65 standards.
Check for transport damage and ensure complete product before installation.
Connections should be made by a qualified electrician, following diagrams.
Offers optical and electrical monitoring options, configurable for minimum or maximum levels.
Regular cleaning is essential, using non-damaging detergents.
Common issues include non-operation due to defective parts, with solutions involving replacements and venting.
LEDs indicate functions and errors.
Used in piston pumps, designed for clean mineral oil and greases up to NLGI-2.
Ensure system is at a standstill before installation or removal.
Monitored with a micro switch for overpressure situations.
Indicates pressure by extracting a pin when the valve opens.
Use lubricants with high-pressure additives and follow specifications.
Ensure a clean environment and correctly fitted pump elements before starting.
GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN
Open the catalog to page 1Importance of safety instructions This operating manual contains important information on handling and safety. Read the operating manual carefully before you start any work with the product. Always have the operating manual available on site. Residual risk Despite the comprehensive safety measures considered for design and operation of our product, the product is not absolutely safe. There remain residual risks, which cannot be eliminated. To mitigate the residual risks: • Take all appropriate precautions as stated in the safety instructions and safety messages. • Observe the operating instructions....
Open the catalog to page 5Symbols used Information labels Wear protective clothing. Wash your hands. Recycle properly.
Open the catalog to page 6This operating manual is intended for: Any person entrusted with tasks involving the product throughout its life cycle. Qualified personnel Only qualified personnel may handle the product. Qualified personnel can recognize and minimize possible hazards due to their skills and knowledge. They are qualified by training, certifications, the relevant degree and/or are instructed accordingly. Authorized persons • Only carry out any installation, inspection or maintenance work at standstill of the product. • Wear appropriate protective equipment. • Depressurize and disconnect the product from power...
Open the catalog to page 7The product is used to convey lubricants within an automatic lubrication system. The product is intended for commercial use only. The product is a machine according to Machinery Directive 2006/42/EC. • Use the product only within the values as stated in the technical data. • Mind the lubricant specifications of the manufacturer. • Observe all relevant regulations for occupational safety and accident prevention during the whole life cycle of the product. Any other use beyond the stated intended use is improper. Improper use can be in particular, but not limited to: • operating the product with...
Open the catalog to page 8Warranty is only granted by the manufacturer for the use as intended and under the following conditions: • Authorized qualified personnel carries out installation, connection and maintenance. • The product is used in accordance with the information in the operating manual. • The limit values as stated in the technical data are not exceeded or gone below. • Only Groeneveld-BEKA may carry out modification and repair of the product. Damage caused by lubricants Damage caused by operation with an unsuitable lubricant will invalidate guarantee and warranty. Groeneveld-BEKA will generally not assume...
Open the catalog to page 9Company name and address of the manufacturer of the machine: Groeneveld-BEKA GmbH Beethovenstraße 14 91257 Pegnitz, Bayern, Germany Tel.: +49 9241729-0 Fax: +49 9241729-50
Open the catalog to page 10General Product Information Product Description The EP-1 is an electrically actuated pump with up to three lubrication outlets. The EP-1 is able to deliver commercial lubricants up to NLGI-2 at a maximum operating pressure of 350 bar. Therefore this system is the ultimate solution for various applications including on-road vehicles, construction equipment, agricultural machinery, and port equipment. System overview: Level monitoring The EP-1 can be equipped with an electronic level monitoring. Reservoir The EP-1 reservoir is made of transparent plastic. EP-1 is available with different reservoir...
Open the catalog to page 11Dimensioned drawing Connection diagram Spare parts drawing Certificates Company name and address of the manufacturer of the machine: Groeneveld-BEKA GmbH 91257 Pegnitz, Bayern, Germany Name and address of the company authorised to compile the technical file: Groeneveld-BEKA Italia S.r.l. 23893 Cassago Brianza (LC), Italy Tel./Fax: +39 039 9215611 THIS DECLARATION OF CONFORMITY APPLIES TO THE FOLLOWING PRODUCT: THE MANUFACTURER DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE PRODUCT COMPLIES WITH THE FOLLOWING EU DIRECTIVES AND HARMONIZED STANDARDS: • Directive 2006/42/EC (Machinery Directive)...
Open the catalog to page 12THIS DECLARATION OF CONFORMITY ALSO APPLIES TO THE FOLLOWING PRODUCT: THE MANUFACTURER DECLARES UNDER ITS OWN RESPONSIBILITY THAT THE PRODUCT COMPLIES WITH THE FOLLOWING EU DIRECTIVES AND HARMONIZED STANDARDS: • Directive 2006/42/EC (Machinery Directive) • Directive 2014/35/EU (Low Voltage Directive) • Directive 2014/30/EU (Electromagnetic Compatibility Directive) • ECE-R10, rev. 6 (Automotive directive of the United Nations) E1 10R-036003 Via Pertini, 1,23893 Cassago Brianza (LC), Italy
Open the catalog to page 134.5 Shutdown and Disposal A WARNING Product under pressure and connected to power You can get injured by: a) liquids which escape due to high pressure. b) electrical power due to high voltage. Mind all relevant national and international laws and regulations for disposal. 2. Switch off electrical power supply. 3. Have electrical components disconnected from the electrical power supply by a trained electrician. 4. Remove all pipes and hoses from the product and detach fittings. 5. When you change the lubricant, observe the disposal instructions of the lubricant manufacturer. 6. Collect lubricants...
Open the catalog to page 14Suspended loads You might get injured if suspended loads fall down. a) Keep distance to suspended loads. b) Wear appropriate protective clothing. • Make sure that the means for transportation or the lifting device has sufficient carrying capacity. • Observe the applicable regulations on safety and accident prevention for transportation. • Do not throw the product or expose it to shocks. • Secure the product against slipping or falling over during transport. • Make sure the product is empty before moving it. • Store the product cool and dry to avoid corrosion. • If the product contains lubricants,...
Open the catalog to page 151) Check the product for transport damage and completeness before installation. 2) Remove transport protection. 3) Select the place of installation so that the product is protected against environmental and mechanical impacts. 4) Ensure unhindered access. 5) Observe the information on fastenings from the dimensional drawing. The product supports the following pump element types: Each element is available with different pipe connections. Depending on the type, the pump element is optionally available with a pressure limiting valve. If your pump is equipped with a transparent reservoir and level...