Technical Specifications:
The AZU oil lubrication pump features a maximum output of 0.06 cm³ per stroke across up to 12 outlets, operating at a maximum pressure of 10 bar. It supports a viscosity range of 25 - 1500 mm²/s and functions optimally within a lubricant temperature range of 0°C to +70°C and an ambient temperature range of 0°C to +40°C. The pump is driven by a rotating mechanism, weighs 1.4 kg, and maintains a sound pressure level below 70dB(A).
General Safety Instructions:
Personnel involved in assembly, start-up, maintenance, and operation must thoroughly read the manual. Safety instructions cover electrical voltage, hot surfaces, and electrostatic discharge. Qualified and trained staff are required, with clear competence and responsibility definitions. Ignoring safety instructions can lead to device failure, personal injury, and environmental hazards.
Operator Obligations:
Operators must protect hazardous parts and manage leakages safely, adhere to legal provisions, and conduct regular inspections of pipes and hoses. Defective components must be replaced immediately, and safety data sheets for lubricants must be accessible.
Maintenance and Assembly:
Only qualified personnel should perform maintenance with the device in a pressureless and disconnected state. Personal protective equipment is necessary, and safety arrangements must be reinstated post-maintenance. Dispose of environmentally hazardous materials according to legal standards.
Unauthorized Modifications:
Modifications and unauthorized production of spare parts are prohibited to ensure safety and device integrity.
Device Acceptance and Safety:
Devices are accepted only after manufacturer feedback. Use of original spare parts and authorized accessories is crucial for safety. Unauthorized parts can void liability for consequences. Groeneveld-BEKA is not liable for retrofitted parts.
Operational Safety:
Ensure operational safety by adhering to the operating manual and not exceeding technical data limits. Electrostatic discharge precautions must be observed according to DIN EN 61340-5-1/-3.
General Hazard Warning:
Devices must be used in a technically acceptable condition, adhering to safety regulations and the operating manual. Regular inspections for damage or leaks are necessary.
Intended Use:
The device is approved for industrial use only and must be operated with compatible machines and lubricants. Unauthorized alterations are prohibited.
Warranty Conditions:
Warranty is valid only if assembly, connection, and maintenance are performed by authorized staff, and the device is used according to the manual. Improper lubricant use voids warranty.
Transport and Storage:
Use suitable lifting devices and secure the device during transport. Store in a cool, dry area to prevent corrosion.
Assembly Instructions:
Check for transport damage before assembly. Ensure balanced installation and protection from environmental influences. Pipes must be clean and pressure-tight.
Start-Up Procedures:
Connect the device to an oil reservoir and ensure proper lubricant levels. Ventilate the lubrication system during initial start-up and after lubricant changes.
Functional Description:
The device operates with a rotating drive shaft, controlling delivery pistons for lubrication. Output rate adjustments are made via a set screw.
Maintenance:
Disconnect from voltage before maintenance. Regularly check for leaks and damage. Lubricant changes should follow manufacturer specifications.
Shutdown and Disposal:
Relieve pressure before disassembly. Dispose of lubricants and devices according to regulations.
Troubleshooting:
Provides solutions for common malfunctions such as suction line leaks, low lubricant levels, and device noise.
Manufacturer Details:
Groeneveld-BEKA GmbH, Germany. Offers a range of lubrication systems and devices.
See more

Catalog excerpts

Original operatingand assembly manual-1

LUBRICATION SYSTEMS BY TIMKEN © Groeneveld-BEKA 2024 All rights reserved!

 Open the catalog to page 1
Original operatingand assembly manual-2

GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN © Groeneveld-BEKA 2024 All rights reserved!

 Open the catalog to page 2
Original operatingand assembly manual-3

Technical data The oil lubrication pump is consecutively called a device. 2. © Groeneveld-BEKA 2024 All rights reser

 Open the catalog to page 3
Original operatingand assembly manual-4

General safety instructions All persons that are in charge with the assembly, start-up, maintenance and operation of the device must carefully read these instructions. Furthermore this manual must permanently be available at the site of operation! Basic notes for setup, operation and maintenance can be found below. 3.1 Safety instructions Do not only observe the safety instructions within this main point but also have a look at the special safety warnings that are included in other parts of this documentation. Warning of electrical voltage. Safety instructions which in case of non-observance...

 Open the catalog to page 4
Original operatingand assembly manual-5

GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN 3.4 Obligations of the operator / user a • If movable, rotating, hot or cold parts of the device bear risks, the customer must protect these parts against /|\ contact. This protection must not be removed. / * \ • Any leakages of hazardous substances must be drained in a way that no risks for persons or the environment • Keep to all legal provisions. • Hazards due to electricity are to be excluded. • Examination of pipes and hoses regarding safe provision, use, proper assembly and function has to be carried out according to regionally applicable directives....

 Open the catalog to page 5
Original operatingand assembly manual-6

General hazard warning – residual risk All components are designed according to valid regulations of the construction of technical systems in regards to operational safety and accident prevention. Independently from this the use can lead to hazards for the user or third parties as well as for other technical facilities. Therefore the device may only fulfill its intended use in a technically acceptable and faultless condition. This has to happen in adherence of the according safety regulations and under observance of the operating manual. Inspect the device and its attachment parts regularly and...

 Open the catalog to page 6
Original operatingand assembly manual-7

GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN Use suitable lifting devices for transport. Do not throw the device or impose it to shocks. Secure the device against toppling down or slipping during transport. A Observe all valid safety and accident prevention regulations for the transport. Wear suitable protective equipment if necessary. Keep adequate distance to suspended loads. The transport help or the elevating device must have the adequate carrying capacity. When storing the device pay attention that the storage area is cool and dry in order to avoid corrosion of the individual parts of the...

 Open the catalog to page 7
Original operatingand assembly manual-8

LUBRICATION SYSTEMS BY TIMKEN 9. Functional description9.1 General The drive of the device occurs rotating. The drive shaft puts the centrally positioned pump shaft and the cam disk with a gear into a rotating movement. This carries out the strokes of the delivery pistons. Max. six delivery pistons are, circular arranged, in the pump body. They are controlled by the rotating movement of the pump shaft over a suction and pressure duct. During the suction stroke is the pressure duct closed and the delivery piston takes in oil from a connected reservoir. After the suction stroke has been finished,...

 Open the catalog to page 8
Original operatingand assembly manual-9

Classification of set screw for pressure connection 10. Maintenance Disconnect the device from voltage before any maintenance or repair. Both, maintenance and repair, may only be carried out at complete standstill and under pressureless condition. Check the surface temperature of the device, as there is the risk of burns due to heat transfer. Wear heat-resistant gloves and safety goggles! Soiled or contaminated surfaces have to be cleaned before maintenance, wear protective equipment to this purpose, if necessary! Protect the device against recommissioning during maintenance/repairs! 10.1 General...

 Open the catalog to page 9
Original operatingand assembly manual-10

GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN Is currently being revised. Is currently being revised. © Groeneveld-BEKA 2024 All rights reserved!

 Open the catalog to page 10
Original operatingand assembly manual-11

GROENEVELD-BEKA LUBRICATION SYSTEMS BY TIMKEN The arrangement of the pressure connections is done in the order of the numbering. If the arrangement is required in another order, this has to be indicated when the order is placed. For outlet number 8, the outlet pairs 1/7, 2/8, 3/9 and 4/10 are drilled. For outlet number 10, there will be additonally the outlet pair 5/11. The suction connection is standard between pos. 1 and 2. © Groeneveld-BEKA 2024 All rights reserved!

 Open the catalog to page 11
Original operatingand assembly manual-12

Groeneveld-BEKA GmbH Beethovenstraße 14 91257 PEGNITZ / Bayern Germany Tel. FAX POSTFACH 1320 91253 PEGNITZ / Bayern Germany Web: E-Mail: www.groeneveld-beka.com [email protected] Our range of supply: Gear pumps Multi-line oil pumps Multi-line grease pumps Single-line central lubrication systems Dual line central lubrication systems Oil circulation central lubrication systems Oil-air and spray lubrication Wheel flange central lubrication systems Rolling mill central lubrication systems Utility vehicle central lubrication systems Progressive distributors Control and monitoring devices...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.