Electrolyser

Electrolyser

Electrolyser

Product catalog summary
Overview: The document provides detailed specifications and features of the ETS Series Stack Test Station by Greenlight Innovation Corporation, designed for testing both PEM and alkaline electrolysers.
Specifications:
  • Power range from 50W to 1MW.
  • DI water supply for anode and cathode with metering pumps.
  • Pressure control up to 50 bar (725 psi) with optional pre-pressurization.
  • Cooling system with recirculation for anode and cathode.
  • Power supply supports constant current and voltage up to 1000A and 1000V.
  • Data acquisition for cell voltage and temperature.
  • Dimensions: 1400 x 1130 x 1800 mm.
Features:
  • Emerald™ control software for automation and user-friendly interface.
  • Automated safety features including hard-wired and software interlocks.
  • Inert gas purge system and remote monitoring capabilities.
  • Expandable for additional I/O and diagnostic tools.
  • CE certificate of conformity available.
Safety and Options:
  • Three levels of safety interlocks.
  • Optional features include gas chromatography, impedance spectroscopy, and product gas analyzers.
  • Unique O-ring sealing technology for high-pressure operations.
  • Optional thermal management and electrical cartridge heating.
Conclusion: The ETS series is positioned as an industry standard for electrolyser testing, offering flexibility, safety, and advanced control features suitable for a range of users from novices to experts.
See more

Catalog excerpts

Electrolyser-1

Electrolyser Stack Test Station • Power ranges from 50W to 1MW • PEM and Alkaline versions available • Featuring Emerald™ control software • Fully automated for unattended operation • Easily expandable for additional I/O and diagnostic tools • Automated hardware and software safety features • Inert gas purge system • Remote monitoring and control • Available CE certificate of conformity

 Open the catalog to page 1
Electrolyser-2

• Anode and cathode DI water supply • DI water and gas separation on outlet • Pressurized control on both anode and cathode • Automatic nitrogen purge on shutdown Additional options include: • Cathode water recirculation • Pre-pressurization • Gas chromatography • Impedance spectroscopy • Anode and cathode product gas analysers • In-line oxygen and hydrogen gas sampling Includes 3 levels of safety: 1. Hard-wired interlocks with emergency stop Greenlight’s ETS series sets the industry standard for both PEM and alkaline electrolyser testing. Emerald™ : Our flexible control software features a user-friendly...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.