1. Catalogs
  2. Greenheck
  3. Model TAUB-L/H
video corpo

Model TAUB-L/H

Model TAUB-L/H
1 / 16 PagesView full catalog

Model TAUB-L/H

Product catalog summary
Overview
The document details the Greenheck Tube Axial Roof Upblast Fans, specifically models TAUB-L and TAUB-H, designed for low and high-pressure applications. These fans are used to efficiently remove and disperse contaminated air, preventing roof damage and recirculation of exhaust air.
Features
- Belt drive with motor and drives out of the airstream.
- Propeller diameters range from 24 to 60 inches.
- Volume range: 4,000 to 60,000 cfm.
- Static pressure: Up to 1.0 inch wg.
- Temperature tolerance: Up to 500ºF continuously.
Support and Delivery
Greenheck provides extensive product literature, electronic media, and a Computer Aided Product Selection program (CAPS) for support. Quick Delivery and Quick Build Programs ensure rapid response times.
Construction and Testing
The TAUB fans are constructed with heavy-duty, welded fabricated steel propellers and are dynamically balanced for vibration-free operation. They are fully assembled and tested before shipment to ensure minimal vibration and electrical safety.
Certifications
The TAUB-L and TAUB-H models are AMCA certified and UL listed for electrical safety and smoke control systems.
High Temperature Options
Various high-temperature options are available for continuous operation and emergency smoke removal, with capabilities to handle temperatures up to 1000°F for specific durations.
Coatings
Greenheck offers advanced zinc-rich powder coatings for superior corrosion resistance, with options like Perma-Z and Hi-Pro-Z providing enhanced durability.
Standard Construction and Accessories
Includes features like outlet screens, fusible link damper lifters, magnetic latches, inspection doors, inlet guards, shaft seals, and tie-down points. Special coatings and roof curbs are also available.
Performance
Performance ratings are provided for various configurations, detailing static pressure and CFM for different fan speeds and horsepower.
Specifications
Each fan model is specified by horsepower (HP), revolutions per minute (RPM), maximum brake horsepower (BHP), sones (a measure of loudness), and decibels (dBA) at free air (F.A.). Static pressure is measured in inches of water gauge (in. wg) across different cubic feet per minute (CFM) values.
Performance Data
The performance data tables list the maximum RPM for both low and high pressure configurations, along with the minimum CFM required to open butterfly dampers for aluminum and steel materials. The tables also provide the maximum motor frame size, shaft diameter, recommended roof opening dimensions, and approximate fan weight in both imperial and metric units.
Material Gauges
The document specifies the material gauges for the fan tube, windband, and curb cap, indicating the thickness of the materials used in construction.
Installation and Dimensions
Detailed dimensions are provided for each fan model, including the recommended roof opening size and the overall dimensions of the fan units. All dimensions are given in both inches and millimeters.
Sound Ratings
The sound ratings are provided in sones, measured at 5 feet in a hemispherical free field, calculated per AMCA Standard 301. These ratings apply to sone levels only and do not include the effects of accessories or transmission losses.
Key Considerations
The document emphasizes that performance ratings do not account for the effects of appurtenances, and power ratings do not include transmission losses. It also highlights the importance of considering installation type and sound seal certifications when evaluating fan performance.
Applications
Typical applications include general exhaust, supply or return air, industrial space and warehouse ventilation, emergency heat and smoke removal, and high temperature process ventilation. TBI-FS models are suitable for high temperature applications with air volumes up to 77,000 cfm and pressures to 4 inches wg.
Commitment
Greenheck reserves the right to change specifications without notice and supports green building efforts. Product warranties are available on their website.
See more

Catalog excerpts

Model TAUB-L/H-1

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller • Belt Drive • Low and High Pressure mGREENHECK Building Value In Air.

 Open the catalog to page 1
Model TAUB-L/H-2

[B.GREENHECK Building Value in Air. Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast roof exhausters, Models TAUB-L and TAUB-H, are designed to efficiently remove and disperse contaminated air. Model TAUB-L is designed for low pressure applications, Model TAUB-H for high pressure applications. The upblast configuration is ideal for exhausting contaminants away from a building to prevent roof damage and recirculation of exhaust air. With the selection of the appropriate high temperature option, the TAUB-L and TAUB-H can also exhaust heat and smoke for either emergency situations...

 Open the catalog to page 2
Model TAUB-L/H-3

Value Added Features Page Header AMCA Licensed & UL/cUL Listed All sizes and configurations of the TAUB-L and TAUB-H have AMCA licensed air and sound performance data. In addition, UL/cUL 705 and UL Power Ventilators for Smoke Control Systems listings are available for TAUB models. Motors may be either 50 or 60 Hz. Greenheck Fan Corporation certifies that the TAUB-L and TAUB-H fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the...

 Open the catalog to page 3
Model TAUB-L/H-4

Tests were conducted at Greenheck’s research and design facilities using a 3.3 million BTU gas-fired burner capable of generating airstream temperatures in excess of 1000°F (538°C). Temperatures were monitored at the following critical locations throughout the tests: bearings, bearing compartment, belt tube, motor, motor compartment, airstream, and fan housing. The following high temperature options and their construction are a result of this extensive testing. CONTINUOUS HI-TEMP OPERATION • HT Option I - 200°-500°F (93o-260°C) The Model TAUB can be built to operate at up to 500°F (260°C) continuously...

 Open the catalog to page 4
Model TAUB-L/H-5

[^GREENHECK Building Value in Air. In 1972, Greenheck took the lead as the first commercial and industrial fan manufacturer to introduce electrostatic powder coatings. Today, Greenheck continues to lead by being the first to offer a superior zinc-rich powder basecoat and powder coating finish. This zinc-rich basecoat technology is used extensively outside the HVAC industry to protect bridge beams, automotive components and other heavy-gauge steel products. Now this advanced technology is exclusively available on Greenheck welded steel products. Greenheck’s coating process starts with a minimum...

 Open the catalog to page 5
Model TAUB-L/H-6

Standard Construction Housing Housing is continuously welded to prevent air leakage. The fan tube, curb cap, windband and motor cover are constructed of heavy gauge steel with Permatector™ coating. Butterfly Dampers Butterfly style dampers feature rolled edges for strength and weather protection. Damper stops maintain proper blade position when fan is operating. Gaskets line the edge of fan discharge for quiet damper closure. For sizes 24-30 aluminum material is standard and steel is standard for sizes 36-60. Aluminum blades optional on larger sizes. Bearings Bearings are air handling quality,...

 Open the catalog to page 6
Model TAUB-L/H-7

Page Header Outlet Screen Fusible Link Damper Lifter Butterfly Dampers Motor Cover Tie Down Points (4 per unit) Adjustable Motor Base Inspection Door Inlet Guard

 Open the catalog to page 7
Model TAUB-L/H-8

[B.GREENHECK Building Value in Air. Performance Data Imperial data — Metric data Material Gauges Minimum CFM required to open butterfly dampers All dimensions in inches (millimeters). TAUB-24L (Low Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal...

 Open the catalog to page 8
Model TAUB-L/H-9

[^GREENHECK Building Value in Air. Performance Data Imperial data — Metric data Material Gauges Minimum CFM required to open butterfly dampers All dimensions in inches (millimeters). TAUB-30L (Low Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal...

 Open the catalog to page 9
Model TAUB-L/H-10

[B.GREENHECK Building Value in Air. Performance Data Imperial data — Metric data Material Gauges Minimum CFM required to open butterfly dampers All dimensions in inches (millimeters). TAUB-36L (Low Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal...

 Open the catalog to page 10
Model TAUB-L/H-11

[^GREENHECK Building Value in Air. Performance Data Imperial data — Metric data Material Gauges Minimum CFM required to open butterfly dampers All dimensions in inches (millimeters). TAUB-42L (Low Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal...

 Open the catalog to page 11
Model TAUB-L/H-12

[B.GREENHECK Building Value in Air. Performance Data Imperial data — Metric data Material Gauges Minimum CFM required to open butterfly dampers All dimensions in inches (millimeters). TAUB-48L (Low Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings (BHP) does not include transmission losses. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.