Industrial Space Heating Direct Gas-Fired Heating • Greenheat® 100% Outdoor Air • 80/20 Recirculation
Open the catalog to page 1Product Overview Industrial Space Heating Greenheck’s space heating systems are designed to heat large spaces as comfortably and economically as possible. Greenheck’s space heating models include the same commitment to quality you would expect from a worldwide leader in air movement and control products. Direct Gas-Fired Heating High-efficiency direct gas-fired burners promote excellent space comfort and low operating cost. The Greenheck space heating line includes the Greenheat® 100% outdoor air, Greenheat® 50/50 recirculation, and the 80/20 recirculation systems. These systems provide a...
Open the catalog to page 2Space Heating Rules of Thumb A Space Heating Capacities Well-insulated buildings Minimally insulated buildings It is recommended that at least two units be used for space heating applications. Multiple units add redundancy and also promote a more even heating distribution across the space. Natural winter infiltration rate is 0.10 to 0.20 ACH for tight buildings. Colder climates will tend to be at the higher end of these ranges. Proven Performance Typical Space Heating Application Greenheck’s space heating systems have heated millions of square feet of warehouses, distributions centers, and...
Open the catalog to page 3System Analysis Greenheat® 100% Outdoor Air System The Greenheat 100% outdoor air systems provide maximum heating with maximum airflow. Air is supplied to the space at a high velocity and high discharge temperature (120-140°F). This unit cycles both the blower and direct-fired burner on a call for heat from a remote space thermostat. Utilizing 100% of the outdoor air positively pressurizes the space to offset the effects of cold air infiltration. This system is great for poorly insulated spaces with high infiltration rates such as warehouses and distribution centers. Greenheat® 50/50...
Open the catalog to page 4Additional Benefits: • Low installation cost on buildings greater than 25,000 ft² • Fresh outdoor air improves IAQ • Provides summer ventilation • Low operating costs • Low moisture content from combustion improves indoor comfort Additional Benefits: • Maximizes discharge air temperature with lower outdoor air volume to provide the highest BTU/cfm ratio in the industry and superior energy savings • Low moisture content from combustion improves indoor comfort • Low installation cost on buildings greater than 25,000 ft² • Provides summer ventilation • Fresh outdoor air and filtered return air...
Open the catalog to page 5Weatherhood • Standard weatherhood with birdscreen for outdoor installations (100% Outdoor Air and 80/20) • Filtered thru-wall weatherhood with 2-inch aluminum mesh filters for indoor installations (100% Outdoor Air) • Louvered weatherhood including a drainable blade louver at intake with 2-inch aluminum mesh filters (50/50) Construction • Designed for maximum weather resistance • Constructed of heavy-gauge G90 galvanized steel • Lifting lugs are standard • Single or double wall construction with 1-inch fiberglass insulation • Large hinged doors and access panels Dampers • Low leakage,...
Open the catalog to page 6Space Heating Controls f^GREENHECK Greenheat® Remote Control Panel • Lockable access • Indicating lights • Keyed switch for summer and winter modes • Thermostat (not shown) is located Greenheat® Temperature Control • The Greenheat® space heating control system cycles the blower and burner on a call for heat from a factory provided space thermostat. 80/20 Remote Control Panel • Includes toggle switches for fan • Room thermostats and photohelic pressure gauge 80/20 Recirculation Temperature Control Room Control (80/20 Standard) • A manually adjusted room thermostat provides feedback to the...
Open the catalog to page 7Installation Roof Mounted Installation Greenheck space heating units feature horizontal (indoor) and downblast (outdoor) discharges as standard, and factory roof curbs are available. Horizontal Discharge - Arrangement HZ Downblast Discharge - Arrangement DB Indoor Installation Greenheat® units have a pre-engineered thru-wall installation option, which is ideal when a roof penetration is not desirable. The following factory options facilitate easy installation and ensure problemfree installation: Weatherhood: A full, downturn design on 100% units, with a generous intake area to minimize...
Open the catalog to page 8System Comparison Greenheat® 100% Outdoor Air Warehouses and Distribution Centers Warehouses, Distribution Centers, and Manufacturing Facilities Uniform Wall-to-Wall Heating Low-to-Medium Insulated Spaces Medium-to-Well Insulated Spaces Well-Insulated Spaces Buildings With High Cold Air Inltration Buildings With Low-to-Medium Cold Air Inltration Buildings With Variable Exhaust Air Volumes Zone Heating Capabilities Number of Units Required Mounting Location Operation Outdoor Air Range Return Air Range Unit Operation Runs Continuously Energy Savings Building Pressure Recirculation Control...
Open the catalog to page 9Dimensions and Weights Greenheat® 100% Outdoor Air and 80/20 Recirculation System Weatherhood w/ Birdscreen Includes V-Bank Filters and Wall Sleeve Not Required with Thru-Wall Weatherhood 3 Includes Outdoor Air and Return Air Dampers (80/20 Units Only) 2 100% Greenheat® Outdoor Air and 80/20 Unit Dimensions Weight Weight 100% (lbs)* 80/20 (lbs)* 1175 1475 All dimensions in inches. * Weights are approximate and do not include accessories external to the unit (diffusers, curbs, etc.) Greenheat® 50/50 Recirculation System Burner Module1 Includes V-Bank Filters, Wall Sleeve, Outdoor Air Damper,...
Open the catalog to page 10Performance Data Greenheat® Housing Total Static Pressure (Ps) Total Static Pressure (in.wg) 1.25 1.50 1.75 Airflow represents total volume delivered to space. Outdoor air volume is one-half of the total volume. All data shown at standard elevation.
Open the catalog to page 11Specifications and Warranty General: Space heat unit shall be manufactured by Greenheck or approved equal providing all specications are met. Greenheck Greenheat® or 80/20 equipment is used as the basis of design. Performance to be as scheduled on plans. Space heat shall be ETL Listed to ANSI Z83.42004, CSA 3.7-M99 (for 100% outdoor air) or ANSI Z83.18-2000 (for recirculation). ® Gas Train and Controls: Direct gas-red system shall have a draw through design and eld adjustable burner bafes. Gas trains up to 400,000 Btu/hr shall include a direct spark ignition system. Gas trains greater than...
Open the catalog to page 12All Greenheck catalogs and technical brochures
-
building value in air WORLDWIDE
56 Pages
-
Model TAUD TAUB-CA
24 Pages
-
Model TAUB-L/H
16 Pages
-
Model AX
8 Pages
-
Models QEI QEID
52 Pages
-
Models TCB TCBRU TCBRS
32 Pages
-
Inline Fans (Models SQ and BSQ)
48 Pages
-
Greenheck Coils Brochure
8 Pages
-
Bypass Air Plenum
2 Pages
-
Belt Drive Duct Fans (Model BDF)
12 Pages
-
Models IDHC and IDHB
8 Pages
-
Centrifugal Roof Exhaust Fans
52 Pages
-
Industrial Process Fans
12 Pages
-
AMCA & Greenheck
2 Pages
-
Air Measuring Products
8 Pages