Features and Benefits:
  • Measures particulate sizes from 0.3 μm to 25 μm with a flow rate of 0.1 CFM (2.83 LPM) using a precision, brushless internal pump.
  • Simultaneously measures and displays particle count data across 6 channels and calculates PM2.5, PM10, and TSP mass concentration in μg/m³.
  • Optional sensors for %RH, temperature, TVOC, and carbon dioxide are available, with high accuracy provided by PID and NDIR technologies.
  • Features a large, icon-driven color touch screen display for ease of use.
  • Stores up to 40,000 sample records in 1,000 location files, with data downloadable to GrayWolf’s WolfSense® PC software.
  • Compatible with GrayWolf’s AdvancedSense® Pro, WolfPack® meters, or DirectSense® tablets for additional parameters and enhanced features.
  • Cloud connectivity available with optional Wireless 802.11 b/g hardware and GrayWolfLive™ software.
  • Complies with ISO 21501-4 and JIS B9921 standards, housed in a lightweight stainless steel enclosure.
  • Includes a 1-year limited warranty.
Specifications:
  • Size range: 0.3 to 25 μm with factory calibration at specific sizes; custom binning available.
  • Flow rate: 0.1 CFM (2.83 LPM).
  • Concentration limit: 4,000,000 particles/ft³ at 5% coincidence loss.
  • Battery run time: 10+ hours for PC-4000, 8+ hours for PC-4005.
  • Light source: Long life laser diode.
  • Counting efficiency: 50% at 0.3 μm; 100% for particles >0.45 μm.
  • Zero count: <1 count/5 minutes.
  • Count modes: Automatic, manual, beep, cumulative/differential counts, or mass concentration.
  • Optional sensors: Carbon dioxide (0 to 5,000 ppm), relative humidity/temperature (0 to 98 %RH, 32 to 122 °F), TVOCs (0 to 50 ppm).
  • Display: 4.3” WQVGA color touch screen.
  • Communication: Serial, USB, optional RS-232/RS-485 Modbus, Ethernet, and Wireless 802.11 b/g.
  • Alarm: Adjustable built-in alarm for counts, low battery, sensor failure, and flow issues.
  • Dimensions: 5.2” x 4.15” x 8.25” (13.3 cm x 10.5 cm x 21 cm).
  • Weight: 4 lb (1.8 kg).
Usage and Connectivity:
  • Can be used as a stand-alone particulate meter or connected to a mobile computer or AdvancedSense/WolfPack system.
  • Data can be downloaded using WolfSense PC Software for creating trend/bar graphs and tables or exported to Microsoft Excel®.
  • Optional Advanced Report Generator software available for automated reporting.
Additional Information:
  • Operating conditions: 41º to 104ºF (5º to 40ºC)/20% to 90%RH non-condensing.
  • Storage conditions: 32º to 122ºF (0º to 50ºC) / Up to 98%RH non-condensing.
  • Warranty: 1-year limited warranty.
See more

Catalog excerpts

PC-4000 6-Channel Particulate/Mass Monitor-1

Advanced Environmental Instrumentation 6-Channel Particle/Mass Monitor Plus Features and Benefits: • Measures particulate 0.3 μm to 25 μm • .1 CFM (2.83 LPM) flow rate via precision, 0 brushless internal pump • easures 6 channels of simultaneous particle M count data • imultaneously displays calculated PM2.5, PM10 S and TSP mass concentration in μg/m³ (pressure compensated w/internal barometric sensor) • Optional %RH and temperature probe • ptional TVOC and/or carbon dioxide sensors; O highly accurate PID and NDIR (PC-4005 only) • arge easy-to-use icon driven color touch L screen display • s a stand-alone, store up to 40,000 sample A records, in up to 1000 location files, for download to GrayWolf’s WolfSense® PC software • onnect to GrayWolf’s AdvancedSense® Pro, C WolfPack® meters or DirectSense® tablets for additional parameters and enhanced features • onnect via the cloud with optional C Wireless 802.11 b/g hardware and GrayWolfLive™ software • Internal audible alarm • omplies with ISO 21501-4 and JIS B9921 standards C • Light weight stainless steel enclosure • 1 year limited warranty Use the PC-4000/5 as a stand-alone particulate meter, plug it into a mobile computer or into a sophisticated AdvancedSense/WolfPack system for simultaneous connection with GrayWolf’s DirectSense probes. • Easily download data from the PC-4000/5 • Offering 6 channels of simultaneous particle ® GRAYWOLF SENSING SOLUTIONS Ph. 1-203-402-0477 Fax: 1-203-402-0478 Email: [email protected] Website: www.GrayWolfSensing.com using the included WolfSense PC Software to create high quality trend/bar graphs/tables with WolfSense’s advanced organizational ® features or simply export to Microsoft Excel . counting, this unit displays both particle counts and (PM) mass concentration (µg/m3). PM 0.5, PM1.0, PM 2.5, PM 5.0, PM 10 and TSP may be concurrently displayed and logged. • Optionally add Advanced Report Generator • Optionally add simultaneous %RH and °C/°F software for extremely efficient, automated reporting of particle count/concentration data. • Easy-to-read 4.3″ (10.9 cm) WQVGA (480x272) color touch screen. (PC-4000) plus TVOCs and/or CO2 (PC-4005). And even more paramete

 Open the catalog to page 1
PC-4000 6-Channel Particulate/Mass Monitor-2

6-Channel Particle/Mass Monitor Plus Size Range ^Shown with optional PC-GW4000-RHT %RH, °C/°F sensor Example A AdvancedSense Pro Screen (interface enables GrayWolf's powerful in-situ features for particulate data) M Hard-shell case (included) Dimensions (L x Wx H) 5.2" x 4.15" x 8.25" (13.3 cm x 10.5 cm x 21 cm) incl. barb fittings (9.5", 24 cm H w/isokinetic inlet) 4 lb (1.8 kg) Quick start guide, operating manual on USB flash drive, isokinetic probe, purge filter, WolfSense® PC data download and report generation software, USB cable, power supply (spec US, UK or Euro plug) Weight Included Accessories...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.